The controller C(s) = 4(s + 2)/s drives the plant G(s) = 2/(s + 10) in a unity-feedback loop. What is the system type N of the loop?
Steady-state error & PID control worksheet with answers
A proportional controller K = 3 drives the plant G(s) = 5/(s + 10) in a unity-feedback loop. A step of size 5 is applied. Find the final value of the output y(∞).
A process G(s) = 2/(10s + 1) is controlled by a proportional gain K = 20 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
The parabolic input r(t) = 4·t²/2 is applied to a unity-feedback loop with G(s) = 10(s + 5)/(s²(s + 5)). Find the steady-state error ess.
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 1/(s + 5) in a unity-feedback loop. The closed loop must have ωₙ = 5 rad/s and ζ = 0.6. Find the integral gain Ki.
A PI controller C(s) = Kp + Ki/s drives the plant G(s) = 2/(s + 2) in a unity-feedback loop. The closed loop must have ωₙ = 8 rad/s and ζ = 0.5. Find the proportional gain Kp.
Answer key
- 1. N = 1
- 2. y(∞) = 3
- 3. ess = 2.439 %
- 4. ess = 0.4
- 5. Ki = 25
- 6. Kp = 3
Full step-by-step solutions: practise this topic on examproblems.com.