A unity-feedback loop has the open-loop transfer function G(s) = 5(s + 2)/(s²(s + 5)). Find the acceleration error constant Ka.
Steady-state error & PID control worksheet with answers
A proportional controller K = 2 drives the plant G(s) = 2/(s + 1) in a unity-feedback loop. A step of size 1 is applied. Find the final value of the output y(∞).
A unity-feedback loop has G(s) = K/((s + 1)(s + 2)). Find the gain K that gives a steady-state error of 4 % for a step input.
A process G(s) = 2.5/(0.5s + 1) is controlled by a proportional gain K = 19 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
A proportional controller K = 10 drives the plant G(s) = 1/(s(s + 5)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
A proportional controller K = 2 drives the plant G(s) = 10/(s(s + 4)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
Answer key
- 1. Ka = 2
- 2. y(∞) = 0.8
- 3. K = 48
- 4. ess = 2.062 %
- 5. %OS = 1.732 %
- 6. ts = 2 s
Full step-by-step solutions: practise this topic on examproblems.com.