The controller C(s) = 4(s + 5)/s drives the plant G(s) = 5/(s + 3) in a unity-feedback loop. What is the system type N of the loop?
Steady-state error & PID control worksheet with answers
A step of size 1 is applied to a unity-feedback loop with G(s) = 2/((s + 1)(s + 10)). Find the steady-state error ess.
The input r(t) = 5 + 2t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 2(s + 4)/(s(s + 4)(s + 10)). Find the steady-state error ess.
The input r(t) = 10 + 2t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 4(s + 1)/(s(s + 5)). Find the steady-state error ess.
A PI controller C(s) = 5 + 4/s drives the plant G(s) = 2/((s + 4)(s + 10)) in a unity-feedback loop. Find the steady-state error ess for the ramp input r(t) = 5t.
A proportional controller K = 40 drives the plant G(s) = 5/(s(s + 4)) in a unity-feedback loop. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
Answer key
- 1. N = 1
- 2. ess = 0.8333
- 3. ess = 10
- 4. ess = 2.5
- 5. ess = 25
- 6. ts = 2 s
Full step-by-step solutions: practise this topic on examproblems.com.