A proportional controller K = 4 drives the plant G(s) = 2/(s + 10) in a unity-feedback loop. A step of size 10 is applied. Find the final value of the output y(∞).
Steady-state error & PID control worksheet with answers
A proportional controller K = 3 drives the plant G(s) = 2/(s + 10) in a unity-feedback loop. A step of size 5 is applied. Find the final value of the output y(∞).
The input r(t) = 1 + 1t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 2(s + 1)/(s(s + 1)(s + 4)). Find the steady-state error ess.
A process G(s) = 2/(10s + 1) is controlled by a proportional gain K = 9 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
A proportional controller K = 40 drives the plant G(s) = 5/(s(s + 6)) in a unity-feedback loop. Find the peak time tp of the step response.
A proportional controller K = 25 drives the plant G(s) = 2/(s(s + 10)) in a unity-feedback loop. Find the peak time tp of the step response.
Answer key
- 1. y(∞) = 4.444
- 2. y(∞) = 1.875
- 3. ess = 2
- 4. ess = 5.263 %
- 5. tp = 0.2273 s
- 6. tp = 0.6283 s
Full step-by-step solutions: practise this topic on examproblems.com.