The controller C(s) = 10(s + 5)/s drives the plant G(s) = 2/(s(s + 4)) in a unity-feedback loop. What is the system type N of the loop?
Steady-state error & PID control worksheet with answers
The controller C(s) = 2(s + 3)/s drives the plant G(s) = 5/(s + 10) in a unity-feedback loop. What is the system type N of the loop?
The input r(t) = 1 + 3t (a step plus a ramp) is applied to a unity-feedback loop with G(s) = 20(s + 4)/(s(s + 4)(s + 10)). Find the steady-state error ess.
The parabolic input r(t) = 2·t²/2 is applied to a unity-feedback loop with G(s) = 5(s + 5)/(s²(s + 2)). Find the steady-state error ess.
A proportional controller K = 25 drives the plant G(s) = 10/(s(s + 10)) in a unity-feedback loop. Find the peak time tp of the step response.
A proportional controller K = 40 drives the plant G(s) = 2/(s(s + 5)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
Answer key
- 1. N = 2
- 2. N = 1
- 3. ess = 1.5
- 4. ess = 0.16
- 5. tp = 0.2094 s
- 6. %OS = 40.07 %
Full step-by-step solutions: practise this topic on examproblems.com.