In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Stability: Routh–Hurwitz & root locus
Stability
all roots of the characteristic polynomial in the left half-plane
Routh array, s¹ entry of a cubic
b1 = (a2a1 − a3a0)/a2
Right half-plane roots
number of sign changes in the first column
Cubic s³ + a₂s² + a₁s + a₀
stable when all a > 0 and a₂·a₁ > a₀
K/(s(s + a)(s + b))
Kmax = ab(a + b), ω = √(ab)
Characteristic equation
1 + K·G(s) = 0
Asymptotes
σa = (Σp − Σz)/(n − m), θ = (2q + 1)·180°/(n − m)
Break-away and break-in points
dK/ds = 0
Magnitude condition
K = 1/|G(s)|
Angle of departure
θd = 180° − Σ∠(from other poles) + Σ∠(from zeros)
Method
Write the closed-loop characteristic polynomial: the denominator of 1 + K·G(s) = 0, multiplied out.
Put the coefficients alternately into the first two rows of the Routh array and build the remaining rows.
Count the sign changes in the first column: each one is a pole in the right half-plane. With K in the array, demand that every first-column entry stays positive.
For a root locus, mark the poles and zeros, the real-axis segments, the asymptotes from the centroid and the break points where dK/ds = 0. Use K = 1/|G(s)| for the gain at a point.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.Laplace transformsMedium
Find f(t) for F(s) = (5s + 13)/(s² + 4s + 5) by completing the square, and evaluate f(0.2).
F(s) = (5s + 13)/(s² + 4s + 5)t = 0.2 s
f(0.2) =
2.Laplace transformsHard
Solve y″ + 7y′ + 6y = 0 with y(0) = −5 and y′(0) = −1 using the Laplace transform, and find y(0.2).
y″ + 7y′ + 6y = 0y(0) = −5y′(0) = −1t = 0.2 s
y(0.2) =
3.Block diagramsMedium
A unity negative feedback loop has G(s) = 2(s + 8)/((s + 1)(s + 7)). A step of size 2 is applied at the reference. Find the steady-state error ess.
G(s) = 2(s + 8)/((s + 1)(s + 7))R = 2
ess =
4.Block diagramsHard
A proportional controller K = 16 drives the plant G(s) = 7/(s + 5) in a unity negative feedback loop. A disturbance D enters at the plant input (it is added to the controller output). With R = 0, a disturbance step of size 10 is applied. Find the steady-state output css.
K = 16G(s) = 7/(s + 5)D = 10R = 0
css =
5.Step responseMedium
A system has the transfer function G(s) = 97/(s² + 10s + 97) and receives a unit step input. Find the 2 % settling time ts of the step response, using ts ≈ 4/(ζωₙ).
G(s) = 97/(s² + 10s + 97)
ts = s
6.Step responseHard
The step response of a second-order system without zeros shows 50 % overshoot, and the first peak occurs at t = 0.2 s. Find the natural frequency ωn.
%OS = 50 %tp = 0.2 s
ωn = rad/s
7.Stability: Routh–Hurwitz & root locusMedium
The plant G(s) = (s + 5)/((s − 4)(s + 3)) has an unstable pole at s = 4. A proportional gain K closes a unity-feedback loop around it. Find the smallest gain Kmin that makes the closed loop stable.
G(s) = (s + 5)/((s − 4)(s + 3))
Kmin =
8.Stability: Routh–Hurwitz & root locusHard
For L(s) = K/((s + 3)(s² + 8s + 17)), find the angle of departure θd of the root locus from the complex pole in the upper half-plane, measured from the positive real axis.
L(s) = K/((s + 3)(s² + 8s + 17))
θd = °
9.Steady-state error & PID controlMedium
A unity-feedback loop with G(s) = K/(s(s + 4)) must follow the ramp r(t) = 5t with a steady-state error of 0.1. Find the gain K.
G(s) = K/(s(s + 4))r(t) = 5tess = 0.1
K =
10.Steady-state error & PID controlHard
A proportional controller K = 20 drives the plant G(s) = 2/(s(s + 4)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 2/(s(s + 4))K = 20
%OS = %
11.Bode plots & marginsMedium
Find the exact magnitude |G(jω)| of G(s) = 3757/((s + 13)(s + 17)) at ω = 15 rad/s, in dB.
G(s) = 3757/((s + 13)(s + 17))ω = 15 rad/s
|G(jω)| = dB
12.Bode plots & marginsHard
A unity-feedback loop has the open-loop transfer function L(s) = 84/(s(s + 3)(s + 5)). Find the phase crossover frequency ω180, where ∠L(jω) = −180°.
L(s) = 84/(s(s + 3)(s + 5))
ω180 = rad/s
3Solutions
1.Laplace transforms
Answer: f(0.2) = 3.684
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Laplace transform: F(s) = ∫₀∞ f(t)·e−st dt turns derivatives into multiplications by s: ℒ{f′} = sF(s) − f(0), ℒ{f″} = s²F(s) − s·f(0) − f′(0). Standard pairs: 1 ↔ 1/s, e−at ↔ 1/(s + a), t·e−at ↔ 1/(s + a)², sin ωt ↔ ω/(s² + ω²), cos ωt ↔ s/(s² + ω²), and a shift s → s + σ multiplies the time function by e−σt. To invert a rational F(s), split it into partial fractions: the residue of a simple pole p is A = [(s − p)·F(s)] at s = p. Final value theorem: f(∞) = lims→0 s·F(s), valid only when all poles of s·F(s) lie in the left half-plane. Initial value theorem: f(0⁺) = lims→∞ s·F(s).
Transform the equation
s²Y − (−5)s − (−1) + 7(sY − (−5)) + 6Y = 0
Y(s) = (−5s − 36)/((s + 1)(s + 6))
Partial fractions
A = −31/5 = −6.2
B = −6/(−5) = 1.2
Result
y(t) = −6.2·e−t + 1.2·e−6t
y(0.2) = −4.715
Answer
y(0.2) = −4.715
Check: y(0) = A + B = −5.
3.Block diagrams
Answer: ess = 0.6087
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Position error constant
Kₚ = G(0) = 2·8/(1·7) = 2.286
Steady-state error
ess = A/(1 + Kₚ) = 2/(1 + 2.286) = 0.6087
Answer
ess = 0.6087
4.Block diagrams
Answer: css = 0.5983
Block-diagram algebra: blocks in series multiply (G₁·G₂), blocks in parallel add (G₁ + G₂), and a loop with forward path G and feedback path H reduces to T = G/(1 + G·H) for negative feedback and G/(1 − G·H) for positive feedback. Reduce inner loops first, then work outwards. The closed-loop poles are the roots of the characteristic equation 1 + G(s)H(s) = 0. For a stable loop, a step input of size A gives the steady-state output A·T(0); with unity feedback the steady-state error to a step is A/(1 + Kp) with Kp = G(0).
Transfer functions
C/D = G/(1 + K·G) = 7/(s + 5 + 112)
Steady state
css = 10·7/117 = 0.5983
Answer
css = 0.5983
A larger K reduces the effect of the disturbance, but never to zero with a proportional controller.
5.Step response
Answer: ts = 0.8 s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 97 → ωₙ = 9.849 rad/s
2ζωₙ = 10 → ζ = 10/(2·9.849) = 0.5077
Result
ζωₙ = 5 → ts ≈ 4/5 = 0.8 s
Answer
ts = 0.8 s
6.Step response
Answer: ωn = 16.09 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Routh–Hurwitz criterion: a linear system is stable when every root of its characteristic polynomial lies in the left half of the s-plane. Write the coefficients alternately into the first two rows of the Routh array. Each entry of a new row comes from the two rows above it; for a cubic a₃s³ + a₂s² + a₁s + a₀ the s¹ entry is b₁ = (a₂·a₁ − a₃·a₀)/a₂. The number of sign changes in the first column equals the number of roots in the right half-plane. With a gain K in the coefficients, every first-column entry must stay positive: the gain that makes the s¹ entry zero is the stability limit, and the s² row then gives the frequency of the sustained oscillation.
For s² + c₁s + c₀ all roots lie in the left half-plane exactly when c₁ > 0 and c₀ > 0.
-1 + K > 0 → K > 1
5K − 12 > 0 → K > 2.4
Kmin = 2.4
Answer
Kmin = 2.4
8.Stability: Routh–Hurwitz & root locus
Answer: θd = −45 °
Root locus: as the gain K goes from 0 to ∞, the closed-loop poles, the roots of 1 + K·G(s) = 0, move from the open-loop poles to the open-loop zeros or to infinity. A point on the real axis belongs to the locus when the number of real poles and zeros to its right is odd. The n − m branches that go to infinity follow asymptotes at the angles (2q + 1)·180°/(n − m), which start from the centroid σₐ = (Σ poles − Σ zeros)/(n − m). Branches leave or join the real axis where dK/ds = 0. The angle condition ∠G(s) = 180° fixes the shape, and the magnitude condition K = 1/|G(s)| gives the gain at any point of the locus.
Pole locations
s² + 8s + 17 = 0 → s = −4 ± j1
s = −3
Angles from the other poles
∠(−4 + j1 + 3) = atan2(1, -1) = 135°
∠(−4 + j1 − (−4 − j1)) = ∠(j2) = 90°
Angle of departure
θd = 180° − 135° − 90° = −45°
Answer
θd = −45°
9.Steady-state error & PID control
Answer: K = 200
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required velocity constant
Kv = A/ess = 5/0.1 = 50
Gain
K = 4·Kv = 200
Answer
K = 200
A large gain makes this loop very lightly damped: ζ = 0.1414. That conflict is why compensators are used.
10.Steady-state error & PID control
Answer: %OS = 35.09 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 4) + 20·2 = s² + 4s + 40
ωₙ and ζ
ωₙ = √40 = 6.325 rad/s
ζ = 4/(2·6.325) = 0.3162
Overshoot
%OS = 100·e−0.3162π/√(1 − 0.3162²) = 35.09 %
Answer
%OS = 35.09 %
11.Bode plots & margins
Answer: |G(jω)| = 18.43 dB
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.
Frequency response: substitute s = jω in the transfer function. The magnitude in decibels is 20·log₁₀|H(jω)| and the phase is the sum of the angles of the numerator factors minus those of the denominator factors. A first-order RC or RL filter has its corner (−3 dB) frequency at ωc = 1/(RC) or R/L, and fc = ωc/(2π); a low-pass filter gives |H| = 1/√(1 + (ω/ωc)²) and φ = −atan(ω/ωc). In the asymptotic (straight-line) Bode plot each pole bends the magnitude down by 20 dB/decade at its corner frequency, each zero bends it up by 20 dB/decade, and an integrator 1/s gives −20 dB/decade at all frequencies. Gain crossover ωc: |L(jω)| = 1 (0 dB); phase margin PM = 180° + ∠L(jωc). Phase crossover ω180: ∠L(jω) = −180°; gain margin GM = −20·log₁₀|L(jω180)| dB. The closed loop is stable when both margins are positive.