In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Measure the QT interval and the R–R interval on this regular lead II strip, then calculate the rate-corrected QTc with Bazett’s formula QTc = QT/√RR (both in seconds). Give the answer in seconds to three decimals.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QTc = s
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1ventricular paced rhythm
2idioventricular rhythm
3paced rhythm, failure to capture
4third-degree (complete) AV block
3.Human physiologyMedium
How does glucagon raise blood glucose?
AIt stimulates glycogen breakdown and gluconeogenesis in the liver
BIt stimulates glucose uptake by muscle
CIt slows glucose absorption from the gut
DIt blocks insulin receptors on fat cells
4.Human physiologyHard
Why is severe hyperkalaemia dangerous for the heart?
AIt depolarises cardiac cells, inactivating sodium channels and causing arrhythmias
BIt hyperpolarises cardiac cells, so they can never fire
CIt speeds up the SA node until tachycardia causes fainting
DIt blocks the binding of calcium to troponin
3Solutions
1.ECG rhythm strip interpretation
Answer: QTc = 0.491 s
QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.
Measure
QT = 13 × 0.04 = 0.52 s
RR = 28 × 0.04 = 1.12 s
Bazett’s formula
QTc = 0.52/√1.12 = 0.52/1.058 = 0.491 s
Answer
QTc = 0.491 s
Above the usual limits for both men (about 0.45 s) and women (about 0.46 s): prolonged. (491 ms)
2.ECG rhythm strip interpretation
Answer: ventricular paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 20 small boxes, 1500 ÷ 20 ≈ 75 per minute.
2. Rhythm: regular, every R–R is 0.80 s.
3. P waves: none visible; a sharp pacing spike comes just before every QRS.
4. PR interval: not measurable.
5. QRS: 0.16 s, wide, and every spike is followed by a QRS (capture).
Interpretation
ventricular paced rhythm
Answer
ventricular paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: A · It stimulates glycogen breakdown and gluconeogenesis in the liver
Why this is the answer
Glucagon from alpha cells acts on the liver to break down glycogen and make new glucose from non-carbohydrate sources.
Answer
A · It stimulates glycogen breakdown and gluconeogenesis in the liver
4.Human physiology
Answer: A · It depolarises cardiac cells, inactivating sodium channels and causing arrhythmias
Why this is the answer
High extracellular potassium makes the resting potential less negative. Many fast sodium channels then become inactivated, slowing conduction and risking fatal arrhythmias.
Answer
A · It depolarises cardiac cells, inactivating sodium channels and causing arrhythmias