In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1sinus rhythm with PVCs
2junctional rhythm
3atrial fibrillation
4sinus arrhythmia
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1third-degree (complete) AV block
2idioventricular rhythm
3dual-chamber (AV) paced rhythm
4ventricular paced rhythm
3.Human physiologyMedium
During contraction of a skeletal muscle sarcomere, which band stays the same length?
AA band
BThe whole sarcomere
CH zone
DI band
4.Human physiologyHard
A healthy person stands up quickly after lying down. Which reflex response prevents fainting?
AThe chemoreceptor reflex raises breathing rate and arterial oxygen levels
BThe Bainbridge reflex lowers heart rate
CThe baroreceptor reflex raises heart rate and vasoconstriction
DADH release immediately doubles blood volume
3Solutions
1.ECG rhythm strip interpretation
Answer: atrial fibrillation
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Five steps
1. Rate: 8 QRS complexes in 6 s, × 10 = 80 per minute.
2. Rhythm: irregularly irregular, R–R from 0.56 to 1.00 s with no pattern.
3. P waves: none; the baseline shows small irregular fibrillatory waves.
4. PR interval: not measurable.
5. QRS: 0.08 s, narrow (below 0.12 s).
Interpretation
atrial fibrillation
Answer
atrial fibrillation
2.ECG rhythm strip interpretation
Answer: ventricular paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 24 small boxes, 1500 ÷ 24 ≈ 63 per minute.
2. Rhythm: regular, every R–R is 0.96 s.
3. P waves: none visible; a sharp pacing spike comes just before every QRS.
4. PR interval: not measurable.
5. QRS: 0.14 s, wide, and every spike is followed by a QRS (capture).
Interpretation
ventricular paced rhythm
Answer
ventricular paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: A · A band
Why this is the answer
In the sliding filament model, filaments slide past each other without shortening. The A band (myosin length) stays the same while the I band and H zone shorten.
Answer
A · A band
4.Human physiology
Answer: C · The baroreceptor reflex raises heart rate and vasoconstriction
Why this is the answer
Blood pools in the legs and pressure falls; baroreceptors fire less, which increases sympathetic and decreases vagal activity within seconds, raising heart rate and vascular tone.
Answer
C · The baroreceptor reflex raises heart rate and vasoconstriction