In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1atrial fibrillation
2sinus rhythm with PVCs
3ventricular bigeminy
4normal sinus rhythm
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1dual-chamber (AV) paced rhythm
2ventricular paced rhythm
3paced rhythm, failure to capture
4sinus rhythm with wide QRS
3.Human physiologyMedium
Since action potentials are all-or-none, how does a neuron signal a stronger stimulus?
ABy changing the neurotransmitter it releases
BBy firing action potentials more often
CBy making each action potential longer
DBy making each action potential larger
4.Human physiologyHard
Why does left ventricular failure cause pulmonary oedema?
APlasma oncotic pressure in the lungs rises sharply
BThe bronchial arteries become blocked
CRaised left atrial pressure increases pulmonary capillary hydrostatic pressure
DThe right ventricle pumps less blood into the lungs
3Solutions
1.ECG rhythm strip interpretation
Answer: sinus rhythm with PVCs
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Five steps
1. Rate: 7 QRS complexes in 6 s, × 10 = 70 per minute.
2. Rhythm: regular (0.88 s) except for the early beats and the pause after each of them.
3. P waves: upright before every narrow QRS; none before the early wide beats.
4. PR interval: 0.14 s, constant, within 0.12–0.20 s.
5. QRS: 0.10 s in the sinus beats; the early beats are wide (0.14 s) and bizarre, with the T wave pointing the other way.
Interpretation
sinus rhythm with PVCs
Answer
sinus rhythm with PVCs
2.ECG rhythm strip interpretation
Answer: ventricular paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 21 small boxes, 1500 ÷ 21 ≈ 71 per minute.
2. Rhythm: regular, every R–R is 0.84 s.
3. P waves: none visible; a sharp pacing spike comes just before every QRS.
4. PR interval: not measurable.
5. QRS: 0.14 s, wide, and every spike is followed by a QRS (capture).
Interpretation
ventricular paced rhythm
Answer
ventricular paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: B · By firing action potentials more often
Why this is the answer
Stimulus strength is coded by the frequency of action potentials and by how many neurons are recruited, not by their amplitude.
Answer
B · By firing action potentials more often
4.Human physiology
Answer: C · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure
Why this is the answer
A failing left ventricle backs up pressure into the left atrium and pulmonary veins. High capillary hydrostatic pressure pushes fluid into the lung interstitium and alveoli.
Answer
C · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure