In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows atrial flutter. Measure the flutter-wave interval and find the atrial rate in beats per minute.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
atrial rate = bpm
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1third-degree (complete) AV block
2idioventricular rhythm
3paced rhythm, failure to capture
4second-degree AV block type II
3.Human physiologyMedium
What is the main stimulus for breathing in a healthy person?
AA rise in arterial CO₂
BA fall in arterial O₂
CA fall in blood pH caused by lactate only
DA rise in blood glucose
4.Human physiologyHard
Spirometry shows reduced FEV1 and reduced FVC, with a normal or high FEV1/FVC ratio. What pattern is this?
AAn obstructive pattern, as in emphysema or chronic bronchitis
BA normal result in an older adult
CAn obstructive pattern, as in asthma
DA restrictive pattern, as in pulmonary fibrosis
3Solutions
1.ECG rhythm strip interpretation
Answer: atrial rate = 250 bpm
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Flutter waves
F–F = 6 small boxes = 0.24 s → 1500 ÷ 6 = 250 per minute
QRS complexes
R–R = 24 small boxes = 0.96 s → 1500 ÷ 24 = 63 per minute
conduction ratio = 250 ÷ 63 = 4:1
Answer
atrial rate = 250 bpm
2.ECG rhythm strip interpretation
Answer: paced rhythm, failure to capture
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: 5 QRS complexes in 6 s, × 10 = 50 per minute.
2. Rhythm: the pacing spikes are regular (every 0.84 s), but the R–R is not, because a QRS is missing after some spikes.
3. P waves: none visible.
4. PR interval: not measurable.
5. QRS: 0.16 s and wide after the captured spikes; 2 spikes are not followed by a QRS (no capture).
Interpretation
paced rhythm, failure to capture
Answer
paced rhythm, failure to capture
Failure to capture: the pacemaker fires but the heart does not respond. Textbooks treat it as urgent to report, because the patient may depend on the pacemaker.
3.Human physiology
Answer: A · A rise in arterial CO₂
Why this is the answer
Central chemoreceptors respond to CO₂ (through the pH of the cerebrospinal fluid). Low O₂ adds strongly to the drive only when PaO₂ falls well below normal, for example at high altitude.
Answer
A · A rise in arterial CO₂
4.Human physiology
Answer: D · A restrictive pattern, as in pulmonary fibrosis
Why this is the answer
In restrictive disease the lungs are small or stiff, so both FEV1 and FVC fall but the ratio is preserved. Obstruction lowers FEV1 more than FVC.
Answer
D · A restrictive pattern, as in pulmonary fibrosis