In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Measure the QT interval and the R–R interval on this regular lead II strip, then calculate the rate-corrected QTc with Bazett’s formula QTc = QT/√RR (both in seconds). Give the answer in seconds to three decimals.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QTc = s
2.ECG rhythm strip interpretationHard
Identify the rhythm on this lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1torsades de pointes
2atrial fibrillation
3asystole
4ventricular fibrillation
3.Human physiologyMedium
Where is the heart's natural pacemaker?
APurkinje fibres
BSinoatrial node
CBundle of His
DAtrioventricular node
4.Human physiologyHard
Why can a patient with carbon monoxide poisoning have a normal PaO₂ but severe tissue hypoxia?
ACO lowers the barometric pressure in the alveoli
BCO blocks diffusion across the alveolar wall
CCO occupies haemoglobin binding sites, so oxygen content falls
DCO stops oxygen from dissolving in plasma
3Solutions
1.ECG rhythm strip interpretation
Answer: QTc = 0.408 s
QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.
Measure
QT = 10 × 0.04 = 0.40 s
RR = 24 × 0.04 = 0.96 s
Bazett’s formula
QTc = 0.40/√0.96 = 0.40/0.9798 = 0.408 s
Answer
QTc = 0.408 s
Within the usual limits (about 0.45 s for men, 0.46 s for women). (408 ms)
2.ECG rhythm strip interpretation
Answer: ventricular fibrillation
Ventricular rhythms: ventricular tachycardia is a run of three or more wide (0.12 s or more) complexes in a row at more than 100/min, usually 150–250/min, regular, without related P waves. Ventricular fibrillation is a chaotic, irregular waveform with no identifiable P waves, QRS complexes or T waves and no countable rate. Asystole is an almost flat line with no ventricular activity; a flat line is always confirmed by checking the patient, the leads and the gain and a second lead. In resuscitation guidelines VF and pulseless VT are the shockable rhythms and asystole is not.
Five steps
1. Rate: no countable ventricular rate.
2. Rhythm: chaotic, no repeating pattern.
3. P waves: none identifiable.
4. PR interval: not measurable.
5. QRS: no QRS complexes.
Interpretation
ventricular fibrillation
Answer
ventricular fibrillation
In resuscitation guidelines VF and pulseless VT are the shockable rhythms. This is identification practice only.
3.Human physiology
Answer: B · Sinoatrial node
Why this is the answer
The SA node depolarises spontaneously at the fastest rate and sets the heart rhythm. The AV node delays the impulse before it spreads to the ventricles.
Answer
B · Sinoatrial node
4.Human physiology
Answer: C · CO occupies haemoglobin binding sites, so oxygen content falls
Why this is the answer
CO binds haemoglobin far more strongly than oxygen and shifts the curve left. Dissolved O₂ (PaO₂) is normal, but total oxygen content and release to tissues drop sharply.
Answer
C · CO occupies haemoglobin binding sites, so oxygen content falls