In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows sinus rhythm with one pause. Measure the pause, the R–R interval across it, in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
pause = s
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1third-degree (complete) AV block
2dual-chamber (AV) paced rhythm
3paced rhythm, failure to capture
4idioventricular rhythm
3.Human physiologyMedium
Mean arterial pressure is approximately equal to:
ACardiac output × total peripheral resistance
BHeart rate × stroke volume
CStroke volume × total peripheral vascular resistance
DCardiac output ÷ heart rate
4.Human physiologyHard
After several days of persistent vomiting of stomach contents, which acid–base disturbance is most likely?
ARespiratory alkalosis
BRespiratory acidosis
CMetabolic alkalosis
DMetabolic acidosis
3Solutions
1.ECG rhythm strip interpretation
Answer: pause = 2 s
Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Measure
50 small boxes from R to R across the pause
Convert
pause = 50 × 0.04 s = 2 s
Compare with P–P
2.00 ÷ 0.80 ≈ 2.5 P–P cycles, not a whole number
Answer
pause = 2 s
No P wave appears in the pause, and the pause is not a whole number of P–P cycles: sinus arrest. A pause of exactly two or three cycles would point to sinus exit block.
2.ECG rhythm strip interpretation
Answer: dual-chamber (AV) paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 24 small boxes, 1500 ÷ 24 ≈ 63 per minute.
2. Rhythm: regular, every R–R is 0.96 s.
3. P waves: each P wave follows its own pacing spike (atrial pacing).
4. AV interval: the second spike comes 0.20 s after the first one (the programmed AV delay).
5. QRS: 0.14 s, wide, right after the second spike (ventricular pacing).
Interpretation
dual-chamber (AV) paced rhythm
Answer
dual-chamber (AV) paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: A · Cardiac output × total peripheral resistance
Why this is the answer
Pressure = flow × resistance, so MAP ≈ CO × TPR. Changes in either cardiac output or vascular resistance change blood pressure.
Answer
A · Cardiac output × total peripheral resistance
4.Human physiology
Answer: C · Metabolic alkalosis
Why this is the answer
Vomiting removes HCl, and the stomach's acid secretion leaves bicarbonate in the blood. Volume loss and low potassium help keep the alkalosis going.