In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1junctional rhythm
2sinus arrhythmia
3sinus tachycardia
4normal sinus rhythm
2.ECG rhythm strip interpretationHard
This lead II strip shows an AV block, so the atria and the ventricles beat at different rates. The QRS complexes are regular: find the ventricular rate in beats per minute (1500 method, whole number).
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
ventricular rate = bpm
3.Human physiologyMedium
Mean arterial pressure is approximately equal to:
ACardiac output ÷ heart rate
BHeart rate × stroke volume
CStroke volume × total peripheral vascular resistance
DCardiac output × total peripheral resistance
4.Human physiologyHard
In pernicious anaemia, autoimmune destruction of gastric parietal cells leads to anaemia because:
AGastrin is lost, so the bone marrow is no longer stimulated
BAcid is lost, so iron is never absorbed in any form
CIntrinsic factor is lost, so vitamin B12 is not absorbed
DPepsin is lost, so haemoglobin cannot be made
3Solutions
1.ECG rhythm strip interpretation
Answer: normal sinus rhythm
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Five steps
1. Rate: R–R = 22 small boxes, 1500 ÷ 22 ≈ 68 per minute.
2. Rhythm: regular, every R–R is 0.88 s.
3. P waves: upright, one before every QRS, all alike.
4. PR interval: 0.14 s, constant, within 0.12–0.20 s.
5. QRS: 0.10 s, narrow (below 0.12 s).
Interpretation
normal sinus rhythm
Answer
normal sinus rhythm
2.ECG rhythm strip interpretation
Answer: ventricular rate = 38 bpm
AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.
Atrial rate
P–P = 20 small boxes = 0.80 s → 1500 ÷ 20 = 75 ≈ 75 per minute
Ventricular rate
R–R = 40 small boxes = 1.60 s → 1500 ÷ 40 = 37.5 ≈ 38 per minute
Answer
ventricular rate = 38 bpm
Answer
ventricular rate = 38 bpm
2:1 AV block: every second P wave is not conducted, so the atrial rate is twice the ventricular rate.
3.Human physiology
Answer: D · Cardiac output × total peripheral resistance
Why this is the answer
Pressure = flow × resistance, so MAP ≈ CO × TPR. Changes in either cardiac output or vascular resistance change blood pressure.
Answer
D · Cardiac output × total peripheral resistance
4.Human physiology
Answer: C · Intrinsic factor is lost, so vitamin B12 is not absorbed
Why this is the answer
Parietal cells secrete intrinsic factor, needed for B12 absorption in the terminal ileum. B12 deficiency impairs DNA synthesis and causes megaloblastic anaemia.
Answer
C · Intrinsic factor is lost, so vitamin B12 is not absorbed