In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1junctional rhythm
2atrial fibrillation
3atrial flutter, 4:1 conduction
4sinus arrhythmia
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1idioventricular rhythm
2dual-chamber (AV) paced rhythm
3third-degree (complete) AV block
4junctional rhythm
3.Human physiologyMedium
During which phase of the cardiac cycle are all four heart valves closed while ventricular pressure rises?
AIsovolumetric contraction
BRapid ejection
CAtrial systole
DRapid filling
4.Human physiologyHard
Why does fetal haemoglobin have a higher affinity for oxygen than adult haemoglobin?
AIt binds 2,3-BPG less strongly
BIt contains more iron per haem
CIt has five subunits instead of four
DFetal blood has a higher pH
3Solutions
1.ECG rhythm strip interpretation
Answer: atrial fibrillation
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Five steps
1. Rate: 8 QRS complexes in 6 s, × 10 = 80 per minute.
2. Rhythm: irregularly irregular, R–R from 0.56 to 0.94 s with no pattern.
3. P waves: none; the baseline shows small irregular fibrillatory waves.
4. PR interval: not measurable.
5. QRS: 0.08 s, narrow (below 0.12 s).
Interpretation
atrial fibrillation
Answer
atrial fibrillation
2.ECG rhythm strip interpretation
Answer: dual-chamber (AV) paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 25 small boxes, 1500 ÷ 25 ≈ 60 per minute.
2. Rhythm: regular, every R–R is 1.00 s.
3. P waves: each P wave follows its own pacing spike (atrial pacing).
4. AV interval: the second spike comes 0.20 s after the first one (the programmed AV delay).
5. QRS: 0.16 s, wide, right after the second spike (ventricular pacing).
Interpretation
dual-chamber (AV) paced rhythm
Answer
dual-chamber (AV) paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: A · Isovolumetric contraction
Why this is the answer
After the AV valves close, the ventricles contract against closed semilunar valves. Pressure rises with no volume change until the aortic and pulmonary valves open.
Answer
A · Isovolumetric contraction
4.Human physiology
Answer: A · It binds 2,3-BPG less strongly
Why this is the answer
The gamma chains of HbF bind 2,3-BPG poorly, so the curve is shifted left. This lets fetal blood take oxygen from maternal blood in the placenta.