In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows sinus rhythm with one pause. Measure the pause, the R–R interval across it, in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
pause = s
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1second-degree AV block type II
2paced rhythm, failure to capture
3dual-chamber (AV) paced rhythm
4idioventricular rhythm
3.Human physiologyMedium
Since action potentials are all-or-none, how does a neuron signal a stronger stimulus?
ABy firing action potentials more often
BBy making each action potential longer
CBy making each action potential larger
DBy changing the neurotransmitter it releases
4.Human physiologyHard
A patient with small-cell lung cancer has low plasma sodium and low plasma osmolality but inappropriately concentrated urine. What is the most likely explanation?
ACranial diabetes insipidus
BAddison's disease with high aldosterone
CPrimary hyperaldosteronism
DSyndrome of inappropriate ADH secretion
3Solutions
1.ECG rhythm strip interpretation
Answer: pause = 1.68 s
Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Measure
42 small boxes from R to R across the pause
Convert
pause = 42 × 0.04 s = 1.68 s
Compare with P–P
1.68 ÷ 0.72 ≈ 2.3 P–P cycles, not a whole number
Answer
pause = 1.68 s
No P wave appears in the pause, and the pause is not a whole number of P–P cycles: sinus arrest. A pause of exactly two or three cycles would point to sinus exit block.
2.ECG rhythm strip interpretation
Answer: paced rhythm, failure to capture
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: 6 QRS complexes in 6 s, × 10 = 60 per minute.
2. Rhythm: the pacing spikes are regular (every 0.80 s), but the R–R is not, because a QRS is missing after some spikes.
3. P waves: none visible.
4. PR interval: not measurable.
5. QRS: 0.16 s and wide after the captured spikes; one spike is not followed by a QRS (no capture).
Interpretation
paced rhythm, failure to capture
Answer
paced rhythm, failure to capture
Failure to capture: the pacemaker fires but the heart does not respond. Textbooks treat it as urgent to report, because the patient may depend on the pacemaker.
3.Human physiology
Answer: A · By firing action potentials more often
Why this is the answer
Stimulus strength is coded by the frequency of action potentials and by how many neurons are recruited, not by their amplitude.
Answer
A · By firing action potentials more often
4.Human physiology
Answer: D · Syndrome of inappropriate ADH secretion
Why this is the answer
In SIADH excess ADH makes the kidneys retain water, diluting the plasma while urine stays concentrated. Small-cell lung cancer can secrete ADH.