ECG Interpretation: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

ECG rhythm strip interpretation

Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)

Method

  1. Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
  2. Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
  3. P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
  4. PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
  5. QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.

2Practice problems

1.ECG rhythm strip interpretationMedium
II25 mm/s · 10 mm/mVsinus bradycardiajunctional rhythmnormal sinus rhythmatrial fibrillation

Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
  1. 1sinus bradycardia
  2. 2junctional rhythm
  3. 3normal sinus rhythm
  4. 4atrial fibrillation
2.ECG rhythm strip interpretationHard
II25 mm/s · 10 mm/mVsecond-degree AV block type IIsecond-degree AV block type I (Wenckebach)atrial fibrillationthird-degree (complete) AV block

This lead II strip shows a conduction problem between the atria and the ventricles. Which rhythm is it? Click your answer.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
  1. 1second-degree AV block type II
  2. 2second-degree AV block type I (Wenckebach)
  3. 3atrial fibrillation
  4. 4third-degree (complete) AV block
3.Human physiologyMedium

Which protein forms the mesh that stabilises a blood clot?

  1. ACollagen
  2. BFibrin
  3. CThrombin
  4. DAlbumin
4.Human physiologyHard

Why does left ventricular failure cause pulmonary oedema?

  1. AThe right ventricle pumps less blood into the lungs
  2. BThe bronchial arteries become blocked
  3. CPlasma oncotic pressure in the lungs rises sharply
  4. DRaised left atrial pressure increases pulmonary capillary hydrostatic pressure

3Solutions

1.ECG rhythm strip interpretation

Answer: junctional rhythm

Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.

Five steps

1. Rate: R–R = 32 small boxes, 1500 ÷ 32 ≈ 47 per minute.
2. Rhythm: regular, every R–R is 1.28 s.
3. P waves: inverted, just before each QRS.
4. PR interval: 0.08 s, shorter than 0.12 s.
5. QRS: 0.08 s, narrow (below 0.12 s).

Interpretation

junctional rhythm

Answer

junctional rhythm
2.ECG rhythm strip interpretation

Answer: second-degree AV block type I (Wenckebach)

AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.

Five steps

1. Rate: 5 QRS complexes in 6 s, × 10 = 50 per minute.
2. Rhythm: regularly irregular, the QRS complexes come in groups separated by a pause (group beating).
3. P waves: upright and regular (P–P 0.88 s, 68 per minute); one P in every 3 is not followed by a QRS.
4. PR interval: lengthens 0.20 → 0.32 s, then a P wave is not conducted.
5. QRS: 0.08 s, narrow (below 0.12 s).

Interpretation

second-degree AV block type I (Wenckebach)

Answer

second-degree AV block type I (Wenckebach)
3.Human physiology

Answer: B · Fibrin

Why this is the answer

Thrombin converts soluble fibrinogen into insoluble fibrin strands, which bind the platelet plug and trap red cells to form a stable clot.

Answer

B · Fibrin
4.Human physiology

Answer: D · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure

Why this is the answer

A failing left ventricle backs up pressure into the left atrium and pulmonary veins. High capillary hydrostatic pressure pushes fluid into the lung interstitium and alveoli.

Answer

D · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure

ExamProblems · examproblems.com/courses/ecg-interpretation