ECG Interpretation: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

ECG rhythm strip interpretation

Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)

Method

  1. Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
  2. Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
  3. P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
  4. PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
  5. QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.

2Practice problems

1.ECG rhythm strip interpretationMedium
II25 mm/s · 10 mm/mV

Measure the QT interval on this lead II strip, in seconds.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QT = s
2.ECG rhythm strip interpretationHard
II25 mm/s · 10 mm/mVsinus rhythm with wide QRSdual-chamber (AV) paced rhythmjunctional rhythmidioventricular rhythm

This patient has a pacemaker. Interpret the lead II strip. Click your answer.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
  1. 1sinus rhythm with wide QRS
  2. 2dual-chamber (AV) paced rhythm
  3. 3junctional rhythm
  4. 4idioventricular rhythm
3.Human physiologyMedium

Which hormone increases water reabsorption in the collecting ducts of the kidney?

  1. AAldosterone
  2. BParathyroid hormone
  3. CAtrial natriuretic peptide
  4. DAntidiuretic hormone (ADH)
4.Human physiologyHard

At the start of a fever, a patient shivers and feels cold even though body temperature is rising. Why?

  1. ASweating has already cooled the body too much
  2. BThe thermoreceptors in the skin are destroyed
  3. CThe body has lost its ability to produce heat
  4. DPyrogens raise the hypothalamic set point above the current body temperature

3Solutions

1.ECG rhythm strip interpretation

Answer: QT = 0.44 s

QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.

Measure

11 small boxes from the start of the QRS to the end of the T wave

Convert

QT = 11 × 0.04 s = 0.44 s

Answer

QT = 0.44 s

A rough rule: at normal rates the QT should be less than half the R–R interval (here R–R = 1.12 s).

2.ECG rhythm strip interpretation

Answer: dual-chamber (AV) paced rhythm

Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.

Five steps

1. Rate: R–R = 25 small boxes, 1500 ÷ 25 ≈ 60 per minute.
2. Rhythm: regular, every R–R is 1.00 s.
3. P waves: each P wave follows its own pacing spike (atrial pacing).
4. AV interval: the second spike comes 0.18 s after the first one (the programmed AV delay).
5. QRS: 0.14 s, wide, right after the second spike (ventricular pacing).

Interpretation

dual-chamber (AV) paced rhythm

Answer

dual-chamber (AV) paced rhythm

The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.

3.Human physiology

Answer: D · Antidiuretic hormone (ADH)

Why this is the answer

ADH (vasopressin) from the posterior pituitary inserts aquaporin-2 channels, making the collecting duct permeable to water and concentrating the urine.

Answer

D · Antidiuretic hormone (ADH)
4.Human physiology

Answer: D · Pyrogens raise the hypothalamic set point above the current body temperature

Why this is the answer

Pyrogens trigger prostaglandin E₂ in the hypothalamus, raising the set point. Until body temperature reaches the new set point, heat-gain responses such as shivering occur.

Answer

D · Pyrogens raise the hypothalamic set point above the current body temperature

ExamProblems · examproblems.com/courses/ecg-interpretation