1Formulas and methods
ECG rhythm strip interpretation
- Paper (25 mm/s, 10 mm/mV)
- 1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
- Heart rate, regular rhythm
- 300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
- Heart rate, irregular rhythm
- QRS complexes in 6 s × 10
- Normal PR interval
- 0.12–0.20 s
- Normal QRS duration
- < 0.12 s
- QTc (Bazett)
- QT/√RR
- QTc (Fridericia)
- QT/∛RR
- QTc (Framingham)
- QT + 154·(1 − RR)
- Sinus rates
- bradycardia < 60, normal 60–100, tachycardia > 100 /min
- Escape rates
- junctional 40–60, ventricular 20–40 /min
- Fast rhythms
- SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
- Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
- Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
- P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
- PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
- QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Measure the QT interval and the R–R interval on this regular lead II strip, then calculate the rate-corrected QTc with Fridericia’s formula QTc = QT/∛RR (both in seconds). Give the answer in seconds to three decimals.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QTc = s
2.ECG rhythm strip interpretationHard
This lead II strip shows second-degree AV block type I (Wenckebach). Measure the PR interval of the last conducted beat before a non-conducted P wave (the longest PR), in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
longest PR = s
3.Human physiologyMedium
What causes the first heart sound (S1)?
- AClosure of the mitral and tricuspid valves
- BBlood filling the atria
- CClosure of the aortic and pulmonary valves
- DOpening of the aortic valve
4.Human physiologyHard
Which mechanism mainly creates the concentration gradient in the medulla of the kidney?
- AADH acting on the descending limb
- BThe countercurrent multiplier of the loop of Henle
- CGlomerular filtration
- DSecretion of urea into the proximal tubule
3Solutions
1.ECG rhythm strip interpretation
Answer: QTc = 0.38 s
QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.
Measure
QT = 9.5 × 0.04 = 0.38 s
RR = 25 × 0.04 = 1.00 s
Fridericia’s formula
QTc = 0.38/∛1.00 = 0.38/1 = 0.38 s
Within the usual limits (about 0.45 s for men, 0.46 s for women). (380 ms)
2.ECG rhythm strip interpretation
Answer: longest PR = 0.28 s
AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.
March out the P waves
P–P = 0.88 s, regular; one P wave in every 3 is not conducted
PR in each group
PR₁ = 0.16 s, PR₂ = 0.28 s
The biggest step in PR comes between the first and second beats of a group; later steps are smaller, which is why the R–R intervals shorten before the pause.
3.Human physiology
Answer: A · Closure of the mitral and tricuspid valves
Why this is the answer
S1 ("lub") is caused by closure of the atrioventricular valves at the start of systole. S2 ("dub") is closure of the semilunar valves.
A · Closure of the mitral and tricuspid valves
4.Human physiology
Answer: B · The countercurrent multiplier of the loop of Henle
Why this is the answer
The ascending limb actively transports NaCl into the interstitium without letting water follow, and the countercurrent flow multiplies this into a steep gradient that ADH then uses to concentrate urine.
B · The countercurrent multiplier of the loop of Henle