ECG Interpretation: cram pack

Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

ECG rhythm strip interpretation

Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)

Method

  1. Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
  2. Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
  3. P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
  4. PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
  5. QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.

2Practice problems

1.ECG rhythm strip interpretationMedium
II25 mm/s · 10 mm/mV

Measure the QT interval and the R–R interval on this regular lead II strip, then calculate the rate-corrected QTc with Fridericia’s formula QTc = QT/∛RR (both in seconds). Give the answer in seconds to three decimals.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
QTc = s
2.ECG rhythm strip interpretationHard
II25 mm/s · 10 mm/mV

This lead II strip shows second-degree AV block type I (Wenckebach). Measure the PR interval of the last conducted beat before a non-conducted P wave (the longest PR), in seconds.

lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
longest PR = s
3.Human physiologyMedium

What causes the first heart sound (S1)?

  1. AClosure of the mitral and tricuspid valves
  2. BBlood filling the atria
  3. CClosure of the aortic and pulmonary valves
  4. DOpening of the aortic valve
4.Human physiologyHard

Which mechanism mainly creates the concentration gradient in the medulla of the kidney?

  1. AADH acting on the descending limb
  2. BThe countercurrent multiplier of the loop of Henle
  3. CGlomerular filtration
  4. DSecretion of urea into the proximal tubule

3Solutions

1.ECG rhythm strip interpretation

Answer: QTc = 0.38 s

QT and QTc: the QT interval runs from the start of the QRS complex to the end of the T wave. It shortens as the heart rate rises, so it is corrected for rate with the R–R interval in seconds: Bazett QTc = QT/√RR and Fridericia QTc = QT/∛RR. Bazett is the formula most textbooks use; it over-corrects at fast rates, where Fridericia is preferred. Limits differ between references: a QTc above about 0.45 s in men or 0.46 s in women is usually called prolonged, and above 0.50 s markedly prolonged.

Measure

QT = 9.5 × 0.04 = 0.38 s
RR = 25 × 0.04 = 1.00 s

Fridericia’s formula

QTc = 0.38/∛1.00 = 0.38/1 = 0.38 s

Answer

QTc = 0.38 s

Within the usual limits (about 0.45 s for men, 0.46 s for women). (380 ms)

2.ECG rhythm strip interpretation

Answer: longest PR = 0.28 s

AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.

March out the P waves

P–P = 0.88 s, regular; one P wave in every 3 is not conducted

PR in each group

PR₁ = 0.16 s, PR₂ = 0.28 s

Answer

longest PR = 0.28 s

The biggest step in PR comes between the first and second beats of a group; later steps are smaller, which is why the R–R intervals shorten before the pause.

3.Human physiology

Answer: A · Closure of the mitral and tricuspid valves

Why this is the answer

S1 ("lub") is caused by closure of the atrioventricular valves at the start of systole. S2 ("dub") is closure of the semilunar valves.

Answer

A · Closure of the mitral and tricuspid valves
4.Human physiology

Answer: B · The countercurrent multiplier of the loop of Henle

Why this is the answer

The ascending limb actively transports NaCl into the interstitium without letting water follow, and the countercurrent flow multiplies this into a steep gradient that ADH then uses to concentrate urine.

Answer

B · The countercurrent multiplier of the loop of Henle

ExamProblems · examproblems.com/courses/ecg-interpretation