In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1sinus bradycardia
2second-degree AV block type II
3sinus rhythm with sinus arrest
4sinus rhythm with PVCs
2.ECG rhythm strip interpretationHard
Identify the rhythm on this lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1idioventricular rhythm
2third-degree (complete) AV block
3junctional rhythm
4asystole
3.Human physiologyMedium
Since action potentials are all-or-none, how does a neuron signal a stronger stimulus?
ABy making each action potential larger
BBy firing action potentials more often
CBy making each action potential longer
DBy changing the neurotransmitter it releases
4.Human physiologyHard
Which spirometry finding is typical of chronic obstructive pulmonary disease (COPD)?
AIncreased peak expiratory flow
BFEV1/FVC ratio below 0.7
CNormal FEV1 with low FVC
DFEV1/FVC ratio above 0.9 with low FVC
3Solutions
1.ECG rhythm strip interpretation
Answer: sinus rhythm with sinus arrest
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC. Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Five steps
1. Rate: 7 QRS complexes in 6 s, × 10 = 70 per minute.
2. Rhythm: regular (R–R 0.80 s) except for one pause of 1.40 s, which is not a whole number of P–P cycles.
3. P waves: upright, one before every QRS; no P wave at all during the pause.
4. PR interval: 0.14 s, constant, within 0.12–0.20 s.
5. QRS: 0.10 s, narrow (below 0.12 s).
Interpretation
sinus rhythm with sinus arrest
Answer
sinus rhythm with sinus arrest
2.ECG rhythm strip interpretation
Answer: idioventricular rhythm
More ventricular rhythms: torsades de pointes is a polymorphic ventricular tachycardia, usually 150–250/min, in which the wide complexes change in height and twist around the baseline, pointing up for a few beats and then down. Textbooks link it to a prolonged QT interval, and magnesium sulfate is the drug resuscitation guidelines name for it. An idioventricular rhythm is a ventricular escape rhythm: regular, wide QRS (0.12 s or more), no P waves, at 20–40/min (an accelerated idioventricular rhythm runs at 40–100/min). Monomorphic VT has identical wide complexes at more than 100/min. VF is chaotic, without any repeating complex.
Five steps
1. Rate: R–R = 42 small boxes, 1500 ÷ 42 ≈ 36 per minute.
2. Rhythm: regular, every R–R is 1.68 s.
3. P waves: none identifiable.
4. PR interval: not measurable.
5. QRS: 0.18 s, wide (0.12 s or more) and bizarre, with the T wave pointing the other way.
Interpretation
idioventricular rhythm
Answer
idioventricular rhythm
An idioventricular rhythm is an escape rhythm: the ventricles take over because the pacemakers above them have failed.
3.Human physiology
Answer: B · By firing action potentials more often
Why this is the answer
Stimulus strength is coded by the frequency of action potentials and by how many neurons are recruited, not by their amplitude.
Answer
B · By firing action potentials more often
4.Human physiology
Answer: B · FEV1/FVC ratio below 0.7
Why this is the answer
Narrowed airways slow expiration, so FEV1 falls more than FVC and the ratio drops below 0.7. In COPD this is not fully reversed by bronchodilators.