1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows sinus rhythm with one pause. Measure the pause, the R–R interval across it, in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
pause = s
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1junctional rhythm
2paced rhythm, failure to capture
3third-degree (complete) AV block
4dual-chamber (AV) paced rhythm
3.Human physiologyMedium
Why does glucose appear in the urine in uncontrolled diabetes mellitus?
AThe glomerulus stops filtering glucose
BThe collecting duct actively secretes glucose
CThe filtered load exceeds the tubular transport maximum
DInsulin is needed for glucose reabsorption in the tubule
4.Human physiologyHard
Spirometry shows reduced FEV1 and reduced FVC, with a normal or high FEV1/FVC ratio. What pattern is this?
AA restrictive pattern, as in pulmonary fibrosis
BAn obstructive pattern, as in asthma
CA normal result in an older adult
DAn obstructive pattern, as in emphysema or chronic bronchitis
3Solutions
1.ECG rhythm strip interpretation
Answer: pause = 1.56 s
Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Measure
39 small boxes from R to R across the pause
Convert
pause = 39 × 0.04 s = 1.56 s
Compare with P–P
1.56 ÷ 0.92 ≈ 1.7 P–P cycles, not a whole number
Answer
pause = 1.56 s
No P wave appears in the pause, and the pause is not a whole number of P–P cycles: sinus arrest. A pause of exactly two or three cycles would point to sinus exit block.
2.ECG rhythm strip interpretation
Answer: dual-chamber (AV) paced rhythm
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: R–R = 22 small boxes, 1500 ÷ 22 ≈ 68 per minute.
2. Rhythm: regular, every R–R is 0.88 s.
3. P waves: each P wave follows its own pacing spike (atrial pacing).
4. AV interval: the second spike comes 0.16 s after the first one (the programmed AV delay).
5. QRS: 0.16 s, wide, right after the second spike (ventricular pacing).
Interpretation
dual-chamber (AV) paced rhythm
Answer
dual-chamber (AV) paced rhythm
The paced QRS is wide by nature; do not call it a bundle branch block or a ventricular rhythm.
3.Human physiology
Answer: C · The filtered load exceeds the tubular transport maximum
Why this is the answer
Proximal tubule SGLT carriers can reabsorb only so much glucose. When plasma glucose is high, the filtered load exceeds this maximum and the excess is excreted.
Answer
C · The filtered load exceeds the tubular transport maximum
4.Human physiology
Answer: A · A restrictive pattern, as in pulmonary fibrosis
Why this is the answer
In restrictive disease the lungs are small or stiff, so both FEV1 and FVC fall but the ratio is preserved. Obstruction lowers FEV1 more than FVC.
Answer
A · A restrictive pattern, as in pulmonary fibrosis