In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows atrial flutter. How many flutter waves per QRS complex are there (the n of n:1 conduction)?
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
flutter waves per QRS =
2.ECG rhythm strip interpretationHard
This lead II strip shows a conduction problem between the atria and the ventricles. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1third-degree (complete) AV block
2second-degree AV block type II
3sinus bradycardia
4second-degree AV block type I (Wenckebach)
3.Human physiologyMedium
Where is the heart's natural pacemaker?
AAtrioventricular node
BBundle of His
CSinoatrial node
DPurkinje fibres
4.Human physiologyHard
A young woman has muscle weakness that gets worse with repeated use and improves with an acetylcholinesterase inhibitor. What is the most likely mechanism?
ADemyelination of central nervous system tracts
BLoss of motor neurons in the spinal cord
CAntibodies against acetylcholine receptors at the neuromuscular junction
DA defect in the dystrophin protein of muscle
3Solutions
1.ECG rhythm strip interpretation
Answer: flutter waves per QRS = 3
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Flutter waves
F–F = 5 small boxes = 0.20 s → 1500 ÷ 5 = 300 per minute
QRS complexes
R–R = 15 small boxes = 0.60 s → 1500 ÷ 15 = 100 per minute
conduction ratio = 300 ÷ 100 = 3:1
Answer
flutter waves per QRS = 3
2.ECG rhythm strip interpretation
Answer: second-degree AV block type II
AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.
Five steps
1. Rate: 4 QRS complexes in 6 s, × 10 = 40 per minute.
2. Rhythm: the P waves are regular; R–R is regular except for a long pause where a QRS is missing.
3. P waves: upright and regular (P–P 0.84 s, 71 per minute); one P in every 3 is not followed by a QRS.
4. PR interval: constant at 0.24 s in the conducted beats.
5. QRS: 0.14 s, wide (0.12 s or more).
Interpretation
second-degree AV block type II
Answer
second-degree AV block type II
Type II and third-degree blocks are the ones that can suddenly progress, so textbooks rank them as more serious than type I.
3.Human physiology
Answer: C · Sinoatrial node
Why this is the answer
The SA node depolarises spontaneously at the fastest rate and sets the heart rhythm. The AV node delays the impulse before it spreads to the ventricles.
Answer
C · Sinoatrial node
4.Human physiology
Answer: C · Antibodies against acetylcholine receptors at the neuromuscular junction
Why this is the answer
In myasthenia gravis, autoantibodies reduce the number of functional acetylcholine receptors. Blocking acetylcholinesterase leaves more ACh to bind the remaining receptors.
Answer
C · Antibodies against acetylcholine receptors at the neuromuscular junction