1Formulas and methods
ECG rhythm strip interpretation
- Paper (25 mm/s, 10 mm/mV)
- 1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
- Heart rate, regular rhythm
- 300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
- Heart rate, irregular rhythm
- QRS complexes in 6 s × 10
- Normal PR interval
- 0.12–0.20 s
- Normal QRS duration
- < 0.12 s
- QTc (Bazett)
- QT/√RR
- QTc (Fridericia)
- QT/∛RR
- QTc (Framingham)
- QT + 154·(1 − RR)
- Sinus rates
- bradycardia < 60, normal 60–100, tachycardia > 100 /min
- Escape rates
- junctional 40–60, ventricular 20–40 /min
- Fast rhythms
- SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
- Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
- Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
- P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
- PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
- QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
This lead II strip shows sinus rhythm with one pause. Measure the pause, the R–R interval across it, in seconds.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
pause = s
2.ECG rhythm strip interpretationHard
This lead II strip shows an AV block, so the atria and the ventricles beat at different rates. Measure the P–P interval and find the atrial rate in beats per minute (1500 method, whole number).
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
atrial rate = bpm
3.Human physiologyMedium
Where is the heart's natural pacemaker?
- ASinoatrial node
- BAtrioventricular node
- CBundle of His
- DPurkinje fibres
4.Human physiologyHard
Why does ketoacidosis typically develop in untreated type 1 diabetes but rarely in type 2?
- AEven low insulin levels suppress lipolysis and ketogenesis
- BKetones are only made in children
- CType 1 patients have more glucagon receptors
- DType 2 patients cannot make ketones at all
3Solutions
1.ECG rhythm strip interpretation
Answer: pause = 1.52 s
Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Measure
38 small boxes from R to R across the pause
Convert
pause = 38 × 0.04 s = 1.52 s
Compare with P–P
1.52 ÷ 0.88 ≈ 1.7 P–P cycles, not a whole number
No P wave appears in the pause, and the pause is not a whole number of P–P cycles: sinus arrest. A pause of exactly two or three cycles would point to sinus exit block.
2.ECG rhythm strip interpretation
Answer: atrial rate = 83 bpm
AV blocks: march out the P waves and check which ones are followed by a QRS. First-degree: every P conducted, PR constant and above 0.20 s. Second-degree type I (Mobitz I, Wenckebach): the PR lengthens from beat to beat until one P wave is not conducted, then the cycle starts again (group beating). Second-degree type II (Mobitz II): the PR of the conducted beats stays constant, and P waves are suddenly not conducted; the QRS is often wide. Third-degree (complete) block: P waves and QRS complexes are each regular but independent, the PR varies at random and the atrial rate is faster than the escape rate (junctional 40–60/min with a narrow QRS, ventricular 20–40/min with a wide QRS). A 2:1 block cannot be called type I or type II from one strip.
Atrial rate
P–P = 18 small boxes = 0.72 s → 1500 ÷ 18 = 83.33 ≈ 83 per minute
Ventricular rate
5 QRS complexes in 6 s × 10 = 50 per minute
Second-degree type II: 3 P waves for every 2 QRS complexes, with a constant PR.
3.Human physiology
Answer: A · Sinoatrial node
Why this is the answer
The SA node depolarises spontaneously at the fastest rate and sets the heart rhythm. The AV node delays the impulse before it spreads to the ventricles.
4.Human physiology
Answer: A · Even low insulin levels suppress lipolysis and ketogenesis
Why this is the answer
Insulin strongly inhibits lipolysis and hepatic ketone production. In type 1 there is almost no insulin, so fatty acids flood the liver and ketones build up.
A · Even low insulin levels suppress lipolysis and ketogenesis