In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1normal sinus rhythm
2sinus rhythm with sinus arrest
3sinus rhythm with PVCs
4sinus arrhythmia
2.ECG rhythm strip interpretationHard
This patient has a pacemaker. Interpret the lead II strip. Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1dual-chamber (AV) paced rhythm
2third-degree (complete) AV block
3idioventricular rhythm
4paced rhythm, failure to capture
3.Human physiologyMedium
What is the main effect of vagus nerve stimulation on the heart?
AIt slows the heart rate
BIt increases the heart rate
CIt constricts the coronary arteries
DIt increases ventricular contractility strongly
4.Human physiologyHard
Why does left ventricular failure cause pulmonary oedema?
APlasma oncotic pressure in the lungs rises sharply
BThe bronchial arteries become blocked
CThe right ventricle pumps less blood into the lungs
DRaised left atrial pressure increases pulmonary capillary hydrostatic pressure
3Solutions
1.ECG rhythm strip interpretation
Answer: sinus rhythm with sinus arrest
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC. Narrow-complex tachycardia and pauses: supraventricular tachycardia (SVT) is a regular tachycardia at about 150–250/min with narrow QRS complexes; the P waves are usually not visible because they are hidden in the QRS complex or the T wave. Sinus tachycardia in an adult at rest is usually below about 150/min and has a visible P wave before every QRS; atrial flutter with 2:1 conduction often runs at about 150/min and shows sawtooth waves. In sinus arrest the sinus node stops firing for a moment: a pause with no P wave and no QRS whose length is not a whole number of P–P cycles (a pause of exactly two or three cycles points to sinus exit block instead).
Five steps
1. Rate: 7 QRS complexes in 6 s, × 10 = 70 per minute.
2. Rhythm: regular (R–R 0.72 s) except for one pause of 1.76 s, which is not a whole number of P–P cycles.
3. P waves: upright, one before every QRS; no P wave at all during the pause.
4. PR interval: 0.16 s, constant, within 0.12–0.20 s.
5. QRS: 0.08 s, narrow (below 0.12 s).
Interpretation
sinus rhythm with sinus arrest
Answer
sinus rhythm with sinus arrest
2.ECG rhythm strip interpretation
Answer: paced rhythm, failure to capture
Paced rhythms: a pacemaker impulse shows as a narrow vertical pacing spike. After a ventricular spike the QRS is wide (0.12 s or more), because the impulse spreads from the lead through the muscle instead of the conduction system; with right-ventricular pacing it is often mostly negative in lead II. A spike before each P wave means atrial pacing, and a dual-chamber (AV) pacemaker shows an atrial spike and a P wave, then, after the programmed AV delay, a ventricular spike and a wide QRS. Capture means every spike is followed by a depolarisation. Failure to capture is a spike without a P wave or QRS after it; failure to sense (spikes that ignore the patient’s own beats) and failure to pace (no spike when one is due) are the other classic malfunctions.
Five steps
1. Rate: 5 QRS complexes in 6 s, × 10 = 50 per minute.
2. Rhythm: the pacing spikes are regular (every 1.00 s), but the R–R is not, because a QRS is missing after some spikes.
3. P waves: none visible.
4. PR interval: not measurable.
5. QRS: 0.14 s and wide after the captured spikes; one spike is not followed by a QRS (no capture).
Interpretation
paced rhythm, failure to capture
Answer
paced rhythm, failure to capture
Failure to capture: the pacemaker fires but the heart does not respond. Textbooks treat it as urgent to report, because the patient may depend on the pacemaker.
3.Human physiology
Answer: A · It slows the heart rate
Why this is the answer
The vagus releases acetylcholine on muscarinic receptors in the SA and AV nodes, slowing pacemaker firing and AV conduction.
Answer
A · It slows the heart rate
4.Human physiology
Answer: D · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure
Why this is the answer
A failing left ventricle backs up pressure into the left atrium and pulmonary veins. High capillary hydrostatic pressure pushes fluid into the lung interstitium and alveoli.
Answer
D · Raised left atrial pressure increases pulmonary capillary hydrostatic pressure