In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
ECG rhythm strip interpretation
Paper (25 mm/s, 10 mm/mV)
1 small box = 0.04 s, 1 large box = 0.20 s, 10 mm = 1 mV
Heart rate, regular rhythm
300 ÷ large boxes = 1500 ÷ small boxes = 60 ÷ RR (s)
Heart rate, irregular rhythm
QRS complexes in 6 s × 10
Normal PR interval
0.12–0.20 s
Normal QRS duration
< 0.12 s
QTc (Bazett)
QT/√RR
QTc (Fridericia)
QT/∛RR
QTc (Framingham)
QT + 154·(1 − RR)
Sinus rates
bradycardia < 60, normal 60–100, tachycardia > 100 /min
Escape rates
junctional 40–60, ventricular 20–40 /min
Fast rhythms
SVT 150–250 /min (narrow), VT > 100 /min (wide)
Method
Rate: for a regular rhythm divide 300 by the large boxes or 1500 by the small boxes between two R waves; for an irregular rhythm count the QRS complexes in 6 seconds and multiply by 10.
Rhythm: compare the R–R intervals. Equal is regular; a repeating pattern is regularly irregular; no pattern at all is irregularly irregular.
P waves: is there an upright P wave in lead II before every QRS, all alike? Look for fibrillatory or sawtooth waves, inverted P waves and P waves without a QRS.
PR interval: from the start of P to the start of the QRS, normally 0.12–0.20 s and constant. Watch whether it lengthens, stays fixed before a dropped beat, or varies at random.
QRS duration: below 0.12 s is narrow; 0.12 s or more is wide. Then name the rhythm, and for the QT use QTc = QT/√RR (Bazett) with times in seconds.
2Practice problems
1.ECG rhythm strip interpretationMedium
Interpret this lead II rhythm strip. Which rhythm is it? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1sinus arrhythmia
2sinus bradycardia
3sinus rhythm with PVCs
4normal sinus rhythm
2.ECG rhythm strip interpretationHard
A monitored patient is found unresponsive and not breathing normally, and no carotid pulse can be felt. The monitor shows this organised rhythm. What is this situation called? Click your answer.
lead II, 25 mm/s, 10 mm/mV1 small box = 0.04 s, 1 large box = 0.20 sstrip length 6 s
1asystole
2pulseless electrical activity (PEA)
3sinus bradycardia
4ventricular fibrillation
3.Human physiologyMedium
Low plasma albumin, as in severe liver disease, causes oedema mainly because:
ACapillary hydrostatic pressure falls
BLymphatic drainage increases
CPlasma oncotic pressure falls
DThe capillaries become impermeable
4.Human physiologyHard
A patient with diabetic ketoacidosis breathes deeply and rapidly. What pattern is expected on the blood gas?
ALow pH, high bicarbonate and high PaCO₂
BLow pH, low bicarbonate and low PaCO₂
CHigh pH, low bicarbonate and low PaCO₂
DLow pH, normal bicarbonate and high PaCO₂
3Solutions
1.ECG rhythm strip interpretation
Answer: sinus arrhythmia
Rhythm criteria (lead II): sinus rhythm has an upright P wave before every QRS, a constant PR of 0.12–0.20 s and a narrow QRS: normal sinus rhythm at 60–100/min, sinus bradycardia below 60, sinus tachycardia above 100. Atrial fibrillation: no P waves, a fibrillatory baseline and an irregularly irregular R–R. Atrial flutter: sawtooth flutter waves at about 250–350/min with a fixed conduction ratio such as 2:1 or 4:1. First-degree AV block: sinus rhythm with a constant PR above 0.20 s. Junctional rhythm: narrow QRS at 40–60/min with absent or inverted P waves (PR below 0.12 s, or P after the QRS). A PVC is an early, wide (0.12 s or more), bizarre QRS without a P wave, with the T wave in the opposite direction and usually a full compensatory pause; in bigeminy every second beat is a PVC.
Five steps
1. Rate: 6 QRS complexes in 6 s, × 10 = 60 per minute.
2. Rhythm: irregular, R–R from 0.74 to 1.06 s, lengthening and shortening gradually.
3. P waves: upright, one before every QRS, all alike.
4. PR interval: 0.18 s, constant, within 0.12–0.20 s.
5. QRS: 0.08 s, narrow (below 0.12 s).
Interpretation
sinus arrhythmia
Answer
sinus arrhythmia
2.ECG rhythm strip interpretation
Answer: pulseless electrical activity (PEA)
Pulseless electrical activity (PEA): PEA cannot be seen on a strip. The monitor shows organised electrical activity (a rhythm other than VF, VT or asystole) but the patient has no palpable pulse, so it is recognised by checking the patient. In adult resuscitation guidelines PEA and asystole are the non-shockable cardiac arrest rhythms: high-quality CPR, epinephrine as soon as possible and a search for reversible causes (the Hs and Ts, such as hypovolaemia, hypoxia, tension pneumothorax and cardiac tamponade). VF and pulseless VT are the shockable rhythms.
What the strip shows
1. Rate: R–R = 32 small boxes, 1500 ÷ 32 ≈ 47 per minute.
2. Rhythm: regular, every R–R is 1.28 s.
3. P waves: upright, one before every QRS, all alike.
4. PR interval: 0.18 s, constant, within 0.12–0.20 s.
5. QRS: 0.10 s, narrow (below 0.12 s).
sinus bradycardia
What the patient shows
no pulse despite organised electrical activity: pulseless electrical activity (PEA), a non-shockable cardiac arrest rhythm
Answer
pulseless electrical activity (PEA)
Answer
pulseless electrical activity (PEA)
PEA is recognised at the bedside, never from the strip alone. This is exam practice, not clinical guidance.
3.Human physiology
Answer: C · Plasma oncotic pressure falls
Why this is the answer
Albumin generates most of the plasma oncotic pressure that pulls fluid back into capillaries. When it falls, more fluid stays in the tissues.