The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the current Ix through the voltage source, from A to B as shown by the arrow.
Is = 1 AVs = 12 VR1 = 4 ΩR2 = 2 Ω
Ix = A
4.Nodal analysisHard
The voltage source Vₛ between A and B has its + terminal at B, so it makes VB − VA = Vₛ. Use nodal analysis with a supernode to find the current Ix through the voltage source, from A to B as shown by the arrow.
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 15 VR1 = 12 ΩR2 = 5 ΩR3 = 3 Ω
IN = A
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 10 VIs = 2 AR1 = 6 ΩR2 = 30 ΩR3 = 30 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the voltage vL across the inductor at t = 1 ms.
Vs = 12 VR = 68 ΩL = 100 mHt = 1 ms
vL = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 3 V with the polarity shown. Find the capacitor voltage vC at t = 400 ms.
Vs = 15 VR = 3.3 kΩC = 220 µFvC(0) = 3 Vt = 400 ms
vC = V
9.AC impedance & phasorsMedium
A resistor and a capacitor are connected in parallel across a 100 V (rms), 200 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 100 V (rms)f = 200 HzR = 25 ΩC = 47 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 12 V (rms), 100 Hz supply. Find the rms current I.
V = 12 V (rms)f = 100 HzR = 10 ΩL = 250 mHC = 100 µF
I = A
11.AC power & power factorMedium
A load with impedance Z = 12 + j9 Ω is connected to a 120 V (rms) single-phase supply. Find the reactive power Q it absorbs.
V = 120 VZ = 12 + j9 Ω
Q = var
12.AC power & power factorHard
A single-phase load takes 20 kW at a power factor of 0.8 lagging from a 240 V, 60 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the reactive power QC the capacitor must supply.
P = 20 kWpf1 = 0.8pf2 = 0.92V = 240 Vf = 60 Hz
QC = kvar
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 100 A from a supply with a line-to-line voltage of 208 V. The power factor is 0.7 lagging. Find the total real power P drawn by the load in kW.
VL = 208 VIL = 100 Acos φ = 0.7
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 250 kW at a power factor of 0.65 lagging from a 690 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.95 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 250 kWpf1 = 0.65pf2 = 0.95VL = 690 Vf = 50 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 2:1 has 240 V applied to its primary winding. A 12 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 2:1V1 = 240 VRL = 12 Ω
I1 = A
16.TransformersHard
A single-phase 250 kVA transformer has a core loss of 1000 W. At rated load and a power factor of 0.95 lagging its efficiency is 96.5%. Find the full-load copper loss Pcu,fl in watts.
S = 250 kVAPcore = 1000 Wpf = 0.95η = 96.5%
Pcu,fl = W
3Solutions
1.Series & parallel resistors
Answer: IR2 = 0.6881 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 15 + 4 = 19 Ω
R2 ∥ 19 = 20·19/(20+19) = 9.744 Ω
Req = R1 + 9.744 = 3 + 9.744 = 12.74 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/12.74 = 1.412 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 18 − 1.412·3 = 13.76 V
IR2 = VA/R2 = 13.76/20 = 0.6881 A
Answer
IR2 = 0.6881 A
2.Series & parallel resistors
Answer: IR2 = 0.2519 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 20 + 2 = 22 Ω
R4 ∥ 22 = 10.48 Ω
R3 + 10.48 = 12.48 Ω
R2 ∥ 12.48 = 3.029 Ω
Req = R1 + 3.029 = 12 + 3.029 = 15.03 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 5/15.03 = 0.3327 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 5 − 0.3327·12 = 1.008 V
IR2 = VA/R2 = 1.008/4 = 0.2519 A
Answer
IR2 = 0.2519 A
3.Nodal analysis
Answer: Ix = 2.667 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + Vs = VA + 12
VA/R1 + VB/R2 = Is
Solve
VA/4 + (VA + 12)/2 = 1
VA = (1 − 12/2)/(1/4 + 1/2) = −6.667 V
VB = −6.667 + 12 = 5.333 V
Current through the voltage source
Everything that passes through the source from A to B leaves node B through R₂.
Ix = VB/R2 = 5.333/2 = 2.667 A
Answer
Ix = 2.667 A
A negative result means the real current flows against the arrow.
4.Nodal analysis
Answer: Ix = −2.955 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Form a supernode
The voltage source between A and B carries an unknown current, so KCL cannot be written at A or B separately. Enclose A, B and the source in one supernode: the current entering it equals the current leaving it.
VB = VA + 12
(VA − V1)/R1 + VA/R2 + VB/R3 = Is
Solve
(VA − 9)/10 + VA/30 + (VA + 12)/20 = 5
VA·(1/10 + 1/30 + 1/20) = 5 + 9/10 − 12/20 = 5.3
VA = 5.3/0.1833 = 28.91 V
VB = 40.91 V
Current through the voltage source
KCL at node A alone: the current arriving through R₁ leaves through R₂ and through the voltage source.
IR1 = (9 − 28.91)/10 = −1.991 A
Ix = IR1 − VA/R2 = −1.991 − 28.91/30 = −2.955 A
Answer
Ix = −2.955 A
A negative result means the real current flows against the arrow.
5.Thévenin & Norton
Answer: IN = 0.6757 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·5/(12+5) = 3.529 Ω
Rth = (R1 ∥ R2) + R3 = 3.529 + 3 = 6.529 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 15·5/(12+5) = 4.412 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 4.412/6.529 = 0.6757 A
6.Thévenin & Norton
Answer: IN = 2.238 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·30/(6+30) = 5 Ω
Rth = (R1 ∥ R2) + R3 = 5 + 30 = 35 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 8.333 + 2·5 = 18.33 V
Vth = VB = VA + Is·R3 = 18.33 + 2·30 = 78.33 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 78.33/35 = 2.238 A
7.RC & RL transients
Answer: vL = 6.079 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 100 mH / 68 Ω = 1.471 ms
i(∞) = Vs/R = 12/68 = 0.1765 A
Inductor voltage
At t = 0 the whole supply voltage appears across the inductor; it then decays to zero.
vL(t) = Vs·e−t/τ = 12·e−1/1.471 = 6.079 V
Answer
vL = 6.079 V
8.RC & RL transients
Answer: vC = 8.083 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
vC(0) = 3 V, vC(∞) = Vs = 15 V
τ = R·C = 3.3 kΩ · 220 µF = 726 ms
vC(t) = 15 + (3 − 15)·e−t/τ
Voltage at the given time
vC(400) = 15 + (−12)·e−400/726 = 8.083 V
Answer
vC = 8.083 V
9.AC impedance & phasors
Answer: φ = −55.89 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(ωC) = 1/(2π·200·47·10⁻⁶) = 16.93 Ω
Branch currents
Both branches are connected straight across the supply, so each sees the full voltage V.
IR = V/R = 100/25 = 4 A
IX = V/XC = 100/16.93 = 5.906 A
Total current
The resistor current is in phase with V and the reactive current is 90° out of phase, so they add like the sides of a right triangle.
I = √(IR² + IX²) = √(4² + 5.906²) = 7.133 A
Phase angle
The capacitor current leads V, so the total current leads and the angle is negative.
φ = −arctan(IX/IR) = −arctan(5.906/4) = −55.89°
Answer
φ = −55.89°
10.AC impedance & phasors
Answer: I = 0.08479 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·100 = 628.3 rad/s
XL = ωL = 628.3·0.25 = 157.1 Ω
XC = 1/(ωC) = 1/(628.3·100·10⁻⁶) = 15.92 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 12/141.5 = 0.08479 A
Answer
I = 0.08479 A
11.AC power & power factor
Answer: Q = 576 var
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Current
|Z| = √(12² + 9²) = 15 Ω
I = V/|Z| = 120/15 = 8 A
Reactive power
Q = I²·X = 8²·9 = 576 var
Answer
Q = 576 var
12.AC power & power factor
Answer: QC = 6.48 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 20·tan(36.87°) = 15 kvar
Q2 = P·tan φ2 = 20·tan(23.07°) = 8.52 kvar
QC = Q1 − Q2 = 6.48 kvar
Answer
QC = 6.48 kvar
13.Three-phase power
Answer: P = 25.22 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·208·100 = 36.03 kVA
Real power
P = S·cos φ = 36.03·0.7 = 25.22 kW
Answer
P = 25.22 kW
14.Three-phase power
Answer: Cph = 468.3 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 250·tan(acos 0.65) = 250·1.169 = 292.3 kvar
Q2 = 250·tan(acos 0.95) = 250·0.3287 = 82.17 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 210.1 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 240/2 = 120 V
I2 = 120/12 = 10 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/2 = 5 A
Answer
I1 = 5 A
Check: the load seen from the primary is a²·RL = 48 Ω, and 240/48 gives the same current.
16.Transformers
Answer: Pcu,fl = 7614 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.