Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 30 VR1 = 10 ΩR2 = 2 ΩR3 = 8 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 15 VIs = 2.5 AR1 = 10 ΩR2 = 15 ΩR3 = 2 Ω
IN = A
7.RC & RL transientsMedium
The inductor carries a steady current of 3 A. At t = 0 the switch closes the loop through R and the source is removed, so the inductor current decays through R. Find the voltage vR across R at t = 1 ms.
i(0) = 3 AR = 33 ΩL = 10 mHt = 1 ms
vR = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 8 V with the polarity shown. How long does it take for vC to reach 6.2 V? Find t.
Vs = 5 VR = 3.3 kΩC = 220 µFvC(0) = 8 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 12 V (rms), 500 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 12 V (rms)f = 500 HzR = 80 ΩL = 20 mHC = 47 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit has R = 10 Ω, L = 20 mH and C = 0.022 µF. Find its bandwidth B (the width of the band between the half-power frequencies), in Hz.
R = 10 ΩL = 20 mHC = 0.022 µF
B = Hz
11.AC power & power factorMedium
An inductive load takes 6 A and 1296 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.
V = 240 VI = 6 AP = 1296 W
X = Ω
12.AC power & power factorHard
A single-phase load takes 50 kW at a power factor of 0.6 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.
P = 50 kWpf1 = 0.6pf2 = 0.92V = 230 Vf = 50 Hz
Inew = A
13.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 20 + j15 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 415 V. Find the total real power P absorbed by the load in kW.
VL = 415 VZ = 20 + j15 Ω per phase
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.65 lagging from a 480 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 300 kWpf1 = 0.65pf2 = 0.98VL = 480 Vf = 60 Hz
Cph = µF
15.TransformersMedium
A single-phase 500 kVA, 4160/480 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 500 kVAV1 = 4160 VV2 = 480 V
ILV = A
16.TransformersHard
A single-phase 75 kVA transformer has a core loss of 225 W and a copper loss of 337.5 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 75 kVAPcore = 225 WPcu,fl = 337.5 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR2 = 2.609 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 2 + 8 = 10 Ω
R2 ∥ 10 = 6·10/(6+10) = 3.75 Ω
Req = R1 + 3.75 = 2 + 3.75 = 5.75 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/5.75 = 4.174 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 24 − 4.174·2 = 15.65 V
IR2 = VA/R2 = 15.65/6 = 2.609 A
Answer
IR2 = 2.609 A
2.Series & parallel resistors
Answer: Req = 5.457 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 2 = 10 Ω
R4 ∥ 10 = 5.455 Ω
R3 + 5.455 = 25.45 Ω
R2 ∥ 25.45 = 3.457 Ω
Req = R1 + 3.457 = 2 + 3.457 = 5.457 Ω
Answer
Req = 5.457 Ω
3.Nodal analysis
Answer: PIs = 11.76 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/10 + (VA − 12)/12 + (VA − VB)/5 = 0
0.3833·VA − 0.2·VB = 1
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/3 + (VB − VA)/5 = 2
−0.2·VA + 0.5333·VB = 2
Solve
Δ = (0.3833)(0.5333) − (−0.2)(−0.2) = 0.1644
VA = Δ1/Δ = 0.9333/0.1644 = 5.676 V
VB = Δ2/Δ = 0.9667/0.1644 = 5.878 V
Power delivered by the current source
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 5.878·2 = 11.76 W
Answer
PIs = 11.76 W
4.Nodal analysis
Answer: VA = 9.551 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = 24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/2 + (VA − 24)/12 + (VA − VB)/6 = 0
0.75·VA − 0.1667·VB = 2
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/30 + (VB − VA)/6 + (VB − 24)/5 = 6
−0.1667·VA + 0.4·VB = 10.8
Solve
Δ = (0.75)(0.4) − (−0.1667)(−0.1667) = 0.2722
VA = Δ1/Δ = 2.6/0.2722 = 9.551 V
VB = Δ2/Δ = 8.433/0.2722 = 30.98 V
Answer
VA = 9.551 V
5.Thévenin & Norton
Answer: Rth = 9.667 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·2/(10+2) = 1.667 Ω
Rth = (R1 ∥ R2) + R3 = 1.667 + 8 = 9.667 Ω
6.Thévenin & Norton
Answer: IN = 3.625 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·15/(10+15) = 6 Ω
Rth = (R1 ∥ R2) + R3 = 6 + 2 = 8 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 9 + 2.5·6 = 24 V
Vth = VB = VA + Is·R3 = 24 + 2.5·2 = 29 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 29/8 = 3.625 A
7.RC & RL transients
Answer: vR = 3.651 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant
τ = L/R = 10 mH / 33 Ω = 0.303 ms
Decay of the current
i(t) = 3·e−1/0.303 = 0.1106 A
vR = R·i = 33·0.1106 = 3.651 V
Answer
vR = 3.651 V
8.RC & RL transients
Answer: t = 665.2 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((8 − 5)/(6.2 − 5)) = 726·ln(2.5) = 665.2 ms
Answer
t = 665.2 ms
9.AC impedance & phasors
Answer: φ = 35.02 °
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.02 = 62.83 Ω
XC = 1/(ωC) = 1/(3142·47·10⁻⁶) = 6.773 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonant frequency
f0 = 1/(2π·√(0.02·0.022·10⁻⁶)) = 7587 Hz
Quality factor
Q compares the reactance at resonance with the resistance: Q = ω₀L/R.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 1296/6² = 36 Ω
Reactance from the impedance
|Z| = V/I = 240/6 = 40 Ω
X = √(|Z|² − R²) = √(40² − 36²) = 17.44 Ω
Answer
X = 17.44 Ω
12.AC power & power factor
Answer: Inew = 236.3 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 50·tan(53.13°) = 66.67 kvar
Q2 = P·tan φ2 = 50·tan(23.07°) = 21.3 kvar
QC = Q1 − Q2 = 45.37 kvar
New line current
Inew = P/(V·cos φ2) = 50000/(230·0.92) = 236.3 A
Answer
Inew = 236.3 A
13.Three-phase power
Answer: P = 16.53 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 415 V
Phase current
|Z| = √(20² + 15²) = 25 Ω
Iph = 415/25 = 16.6 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·16.6²·20 = 16.53 kW
Answer
P = 16.53 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
14.Three-phase power
Answer: Cph = 3337 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.65) = 300·1.169 = 350.7 kvar
Q2 = 300·tan(acos 0.98) = 300·0.2031 = 60.92 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 289.8 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 500000/480 = 1042 A
Answer
ILV = 1042 A
16.Transformers
Answer: Sη,max = 61.24 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.