Find the Thévenin resistance Rth seen from terminals a–b.
V1 = 9 VR1 = 8 ΩR2 = 3 ΩR3 = 4 Ω
Rth = Ω
6.Thévenin & NortonHard
Find the Norton current IN: the current that flows from a to b if the terminals are shorted.
V1 = 24 VIs = 1 AR1 = 4 ΩR2 = 15 ΩR3 = 6 Ω
IN = A
7.RC & RL transientsMedium
The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 120 ms.
Vs = 30 VR1 = 3.3 kΩR2 = 2.2 kΩC = 220 µFt = 120 ms
vC = V
8.RC & RL transientsHard
The switch across R2 has been open for a long time, so the inductor current is steady. At t = 0 the switch closes and shorts out R2. How long after t = 0 does the inductor current reach 0.182 A? Find t.
Vs = 9 VR1 = 47 ΩR2 = 5 ΩL = 22 mH
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 50 V (rms), 50 Hz supply. Find the phase angle φ of the impedance, in degrees (positive when the current lags the voltage).
V = 50 V (rms)f = 50 HzR = 10 ΩL = 50 mHC = 100 µF
φ = °
10.AC impedance & phasorsHard
A series RLC circuit is driven by a 12 V (rms) source whose frequency is set to the resonant frequency of the circuit. Find the rms voltage VL across the inductor.
V = 12 V (rms)R = 5 ΩL = 10 mHC = 4.7 µF
VL = V
11.AC power & power factorMedium
An inductive load takes 8 A and 1344 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.
V = 240 VI = 8 AP = 1344 W
R = Ω
12.AC power & power factorHard
A single-phase load takes 10 kW at a power factor of 0.65 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.98. Find the new line current Inew.
P = 10 kWpf1 = 0.65pf2 = 0.98V = 400 Vf = 50 Hz
Inew = A
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 10 A from a supply with a line-to-line voltage of 400 V. The power factor is 0.9 lagging. Find the total real power P drawn by the load in kW.
VL = 400 VIL = 10 Acos φ = 0.9
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.75 lagging from a 690 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Y. Find the capacitance Cph of each capacitor in µF.
P = 300 kWpf1 = 0.75pf2 = 0.98VL = 690 Vf = 60 Hz
Cph = µF
15.TransformersMedium
An amplifier with an output resistance of 1250 Ω drives a 50 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 1250 Ω from the amplifier. Find the turns ratio a = N₁/N₂.
Rs = 1250 ΩRL = 50 Ω
a =
16.TransformersHard
A single-phase 50 kVA transformer has a core loss of 400 W and a copper loss of 800 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 50 kVAPcore = 400 WPcu,fl = 800 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR2 = 0.5714 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 20 + 20 = 40 Ω
R2 ∥ 40 = 6·40/(6+40) = 5.217 Ω
Req = R1 + 5.217 = 10 + 5.217 = 15.22 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 10/15.22 = 0.6571 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 10 − 0.6571·10 = 3.429 V
IR2 = VA/R2 = 3.429/6 = 0.5714 A
Answer
IR2 = 0.5714 A
2.Series & parallel resistors
Answer: IR1 = 1.18 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 20 + 12 = 32 Ω
R4 ∥ 32 = 12.31 Ω
R3 + 12.31 = 27.31 Ω
R2 ∥ 27.31 = 8.337 Ω
Req = R1 + 8.337 = 12 + 8.337 = 20.34 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/20.34 = 1.18 A
Answer
IR1 = 1.18 A
3.Nodal analysis
Answer: IR3 = 1.316 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/2 + (VA − 10)/8 + (VA − VB)/4 = 0
0.875·VA − 0.25·VB = 1.25
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
VA is known, so this equation gives VB.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
(3 − 10)/15 + 3/5 = (VB − 3)/3
0.1333 = (VB − 3)/3 → VB = 3.4 V
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Is = (VB − VA)/R3 + VB/R4 = (3.4 − 3)/3 + 3.4/12 = 0.4167 A
Answer
Is = 0.4167 A
5.Thévenin & Norton
Answer: Rth = 6.182 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·3/(8+3) = 2.182 Ω
Rth = (R1 ∥ R2) + R3 = 2.182 + 4 = 6.182 Ω
6.Thévenin & Norton
Answer: IN = 3.069 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 4·15/(4+15) = 3.158 Ω
Rth = (R1 ∥ R2) + R3 = 3.158 + 6 = 9.158 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 18.95 + 1·3.158 = 22.11 V
Vth = VB = VA + Is·R3 = 22.11 + 1·6 = 28.11 V
Norton equivalent
A Norton source is the same circuit seen as a current source in parallel with R_th. Its current is the short-circuit current at a–b.
IN = Vth/Rth = 28.11/9.158 = 3.069 A
7.RC & RL transients
Answer: vC = 4.062 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 3.3·2.2/(3.3 + 2.2) = 1.32 kΩ
vC(∞) = 30·2.2/(3.3 + 2.2) = 12 V
Time constant
τ = Rth·C = 1.32·220 = 290.4 ms
Charging curve
vC(t) = 12·(1 − e−120/290.4) = 4.062 V
Answer
vC = 4.062 V
8.RC & RL transients
Answer: t = 0.3103 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
Before t = 0 both resistors are in the loop; afterwards the closed switch bypasses R₂.
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·50 = 314.2 rad/s
XL = ωL = 314.2·0.05 = 15.71 Ω
XC = 1/(ωC) = 1/(314.2·100·10⁻⁶) = 31.83 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the reactances cancel, so the impedance is just R.
ω₀ = 1/√(LC) = 1/√(0.01·4.7·10⁻⁶) = 4613 rad/s
I = V/R = 12/5 = 2.4 A
Voltage across the inductor
XL = ω₀L = 4613·0.01 = 46.13 Ω
VL = I·XL = 2.4·46.13 = 110.7 V
Answer
VL = 110.7 V
This is Q = 9.225 times the supply voltage.
11.AC power & power factor
Answer: R = 21 Ω
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 1344/8² = 21 Ω
Answer
R = 21 Ω
12.AC power & power factor
Answer: Inew = 25.51 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 10·tan(49.46°) = 11.69 kvar
Q2 = P·tan φ2 = 10·tan(11.48°) = 2.031 kvar
QC = Q1 − Q2 = 9.661 kvar
New line current
Inew = P/(V·cos φ2) = 10000/(400·0.98) = 25.51 A
Answer
Inew = 25.51 A
13.Three-phase power
Answer: P = 6.235 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·400·10 = 6.928 kVA
Real power
P = S·cos φ = 6.928·0.9 = 6.235 kW
Answer
P = 6.235 kW
14.Three-phase power
Answer: Cph = 1135 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.75) = 300·0.8819 = 264.6 kvar
Q2 = 300·tan(acos 0.98) = 300·0.2031 = 60.92 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 203.7 kvar
Capacitance per phase
In a Y bank each capacitor is connected between a line and the star point.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Match the referred load
a²·50 = 1250
a = √(1250/50) = √25 = 5
Answer
a = 5
16.Transformers
Answer: Sη,max = 35.36 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.