The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the capacitor voltage vC at t = 400 ms.
Vs = 15 VR1 = 4.7 kΩR2 = 2.2 kΩC = 220 µFt = 400 ms
vC = V
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 10 V with the polarity shown. How long does it take for vC to reach 9.3 V? Find t.
Vs = 9 VR = 10 kΩC = 10 µFvC(0) = 10 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 24 V (rms), 60 Hz supply. Find the rms current I.
V = 24 V (rms)f = 60 HzR = 80 ΩL = 100 mHC = 100 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 12 V (rms), 500 Hz supply. Find the resonant frequency f0 of the circuit.
V = 12 V (rms)f = 500 HzR = 20 ΩL = 20 mHC = 47 µF
f0 = Hz
11.AC power & power factorMedium
A single-phase motor takes 9 kW at a power factor of 0.8 lagging from a 230 V supply. Find the line current I.
P = 9 kWpf = 0.8V = 230 V
I = A
12.AC power & power factorHard
A 120 V (rms), 1000 Hz source has an internal impedance Zs = 20 + j40 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.
Vs = 120 V (rms)f = 1000 HzZs = 20 + j40 Ω
Pmax = W
13.Three-phase powerMedium
A three-phase induction motor delivers 90 kW of mechanical output power at full load. At this load its efficiency is 91% and its power factor is 0.88 lagging. The supply has a line-to-line voltage of 690 V. Find the line current IL.
Pout = 90 kWη = 91%cos φ = 0.88VL = 690 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 120 kW at a power factor of 0.72 lagging from a 690 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 120 kWpf1 = 0.72pf2 = 0.98VL = 690 Vf = 50 Hz
QC = kvar
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 10:1 has 1200 V applied to its primary winding. A 4 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 10:1V1 = 1200 VRL = 4 Ω
I1 = A
16.TransformersHard
A single-phase 500 kVA transformer has a core loss of 2500 W. At rated load and a power factor of 0.8 lagging its efficiency is 98%. Find the full-load copper loss Pcu,fl in watts.
S = 500 kVAPcore = 2500 Wpf = 0.8η = 98%
Pcu,fl = W
3Solutions
1.Series & parallel resistors
Answer: Req = 6.2 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 4 + 10 = 14 Ω
R2 ∥ 14 = 6·14/(6+14) = 4.2 Ω
Req = R1 + 4.2 = 2 + 4.2 = 6.2 Ω
Answer
Req = 6.2 Ω
2.Series & parallel resistors
Answer: Req = 9.765 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 10 = 18 Ω
R4 ∥ 18 = 11.25 Ω
R3 + 11.25 = 15.25 Ω
R2 ∥ 15.25 = 3.765 Ω
Req = R1 + 3.765 = 6 + 3.765 = 9.765 Ω
Answer
Req = 9.765 Ω
3.Nodal analysis
Answer: VB = 28.22 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 10 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/8 + (VA − 10)/5 + (VA − VB)/4 = 0
0.575·VA − 0.25·VB = 2
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/15 + (VB − VA)/4 = 5
−0.25·VA + 0.3167·VB = 5
Solve
Δ = (0.575)(0.3167) − (−0.25)(−0.25) = 0.1196
VA = Δ1/Δ = 1.883/0.1196 = 15.75 V
VB = Δ2/Δ = 3.375/0.1196 = 28.22 V
Answer
VB = 28.22 V
4.Nodal analysis
Answer: VB = −12.57 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V, V2 = −24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/6 + (VA − 24)/25 + (VA − VB)/12 = 0
0.29·VA − 0.08333·VB = 0.96
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·20/(3+20) = 2.609 Ω
Rth = (R1 ∥ R2) + R3 = 2.609 + 15 = 17.61 Ω
6.Thévenin & Norton
Answer: IL = 4.459 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 30·2/(30+2) = 1.875 Ω
Rth = (R1 ∥ R2) + R3 = 1.875 + 15 = 16.88 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 0.75 + 6·1.875 = 12 V
Vth = VB = VA + Is·R3 = 12 + 6·15 = 102 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 102/(16.88 + 6) = 4.459 A
7.RC & RL transients
Answer: vC = 3.361 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 4.7·2.2/(4.7 + 2.2) = 1.499 kΩ
vC(∞) = 15·2.2/(4.7 + 2.2) = 4.783 V
Time constant
τ = Rth·C = 1.499·220 = 329.7 ms
Charging curve
vC(t) = 4.783·(1 − e−400/329.7) = 3.361 V
Answer
vC = 3.361 V
8.RC & RL transients
Answer: t = 120.4 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((10 − 9)/(9.3 − 9)) = 100·ln(3.333) = 120.4 ms
Answer
t = 120.4 ms
9.AC impedance & phasors
Answer: I = 0.2971 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·60 = 377 rad/s
XL = ωL = 377·0.1 = 37.7 Ω
XC = 1/(ωC) = 1/(377·100·10⁻⁶) = 26.53 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 24/80.78 = 0.2971 A
Answer
I = 0.2971 A
10.AC impedance & phasors
Answer: f0 = 164.2 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 9000/(230·0.8) = 48.91 A
Answer
I = 48.91 A
12.AC power & power factor
Answer: Pmax = 180 W
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 20 − j40 Ω
Maximum power
I = Vs/(2Rs) = 120/40 = 3 A
Pmax = I²·RL = Vs²/(4Rs) = 120²/(4·20) = 180 W
Answer
Pmax = 180 W
13.Three-phase power
Answer: IL = 94.04 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 90/0.91 = 98.9 kW
Line current
IL = Pin/(√3·VL·cos φ) = 98901/(√3·690·0.88) = 94.04 A
Answer
IL = 94.04 A
14.Three-phase power
Answer: QC = 91.3 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 120·tan(acos 0.72) = 120·0.9639 = 115.7 kvar
Q2 = 120·tan(acos 0.98) = 120·0.2031 = 24.37 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 91.3 kvar
Answer
QC = 91.3 kvar
15.Transformers
Answer: I1 = 3 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 1200/10 = 120 V
I2 = 120/4 = 30 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/10 = 3 A
Answer
I1 = 3 A
Check: the load seen from the primary is a²·RL = 400 Ω, and 1200/400 gives the same current.
16.Transformers
Answer: Pcu,fl = 5663 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.