The diamond is a voltage-controlled current source that pushes a current of 0.5·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VA (measured from ground).
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 12 VR1 = 2 ΩR2 = 4 ΩR3 = 12 Ω
Vth = V
6.Thévenin & NortonHard
Find the Thévenin voltage Vth seen from terminals a–b.
V1 = 9 VIs = 1.5 AR1 = 8 ΩR2 = 25 ΩR3 = 4 Ω
Vth = V
7.RC & RL transientsMedium
The inductor carries no current before the switch closes at t = 0. Find the current i at t = 1 ms.
Vs = 5 VR = 47 ΩL = 47 mHt = 1 ms
i = A
8.RC & RL transientsHard
A timer starts charging an uncharged capacitor through a resistor from a 12 V supply at t = 0. It must trigger when the capacitor voltage reaches 10.8 V, exactly 500 ms after the start. With C = 1 µF, find the resistance R needed.
Vs = 12 VVth = 10.8 VT = 500 msC = 1 µF
R = kΩ
9.AC impedance & phasorsMedium
A series RLC circuit with L = 2 mH must resonate at 100 Hz. Find the capacitance C needed.
f0 = 100 HzL = 2 mH
C = µF
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 120 V (rms), 60 Hz supply. Find the resonant frequency f0 of the circuit.
V = 120 V (rms)f = 60 HzR = 80 ΩL = 100 mHC = 4.7 µF
f0 = Hz
11.AC power & power factorMedium
A load with impedance Z = 8 + j6 Ω is connected to a 230 V (rms) single-phase supply. Find the real power P it absorbs.
V = 230 VZ = 8 + j6 Ω
P = W
12.AC power & power factorHard
A 120 V (rms), 60 Hz source has an internal impedance Zs = 50 + j30 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Vs = 120 V (rms)f = 60 HzZs = 50 + j30 Ω
C = µF
13.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 5 + j12 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 415 V. Find the total real power P absorbed by the load in kW.
VL = 415 VZ = 5 + j12 Ω per phase
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 150 kW at a power factor of 0.78 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 150 kWpf1 = 0.78pf2 = 0.92VL = 415 Vf = 60 Hz
Cph = µF
15.TransformersMedium
A single-phase 50 kVA, 10000/400 V transformer operates at its rated load. Treat it as ideal. Find the current ILV in the low-voltage winding.
S = 50 kVAV1 = 10000 VV2 = 400 V
ILV = A
16.TransformersHard
A single-phase 25 kVA transformer has a core loss of 100 W and a copper loss of 200 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 25 kVAPcore = 100 WPcu,fl = 200 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR1 = 1.458 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 6 + 20 = 26 Ω
R2 ∥ 26 = 2·26/(2+26) = 1.857 Ω
Req = R1 + 1.857 = 5 + 1.857 = 6.857 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 10/6.857 = 1.458 A
Answer
IR1 = 1.458 A
2.Series & parallel resistors
Answer: Req = 28.56 Ω
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 3 + 3 = 6 Ω
R4 ∥ 6 = 2 Ω
R3 + 2 = 32 Ω
R2 ∥ 32 = 3.556 Ω
Req = R1 + 3.556 = 25 + 3.556 = 28.56 Ω
Answer
Req = 28.56 Ω
3.Nodal analysis
Answer: PIs = 37.37 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/15 + (VA − 30)/8 + (VA − VB)/10 = 0
0.2917·VA − 0.1·VB = 3.75
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/2 + (VB − VA)/10 = 4
−0.1·VA + 0.6·VB = 4
Solve
Δ = (0.2917)(0.6) − (−0.1)(−0.1) = 0.165
VA = Δ1/Δ = 2.65/0.165 = 16.06 V
VB = Δ2/Δ = 1.542/0.165 = 9.343 V
Power delivered by the current source
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 9.343·4 = 37.37 W
Answer
PIs = 37.37 W
4.Nodal analysis
Answer: VA = 4.412 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.65·VA − 0.08333·VB = 2.5
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
(VB − VA)/R3 + VB/R4 = 0.5·VA
−0.5833·VA + 0.5833·VB = 0
Solve
Δ = (0.65)(0.5833) − (−0.08333)(−0.5833) = 0.3306
VA = Δ1/Δ = 1.458/0.3306 = 4.412 V
VB = Δ2/Δ = 1.458/0.3306 = 4.412 V
Answer
VA = 4.412 V
5.Thévenin & Norton
Answer: Vth = 8 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 2·4/(2+4) = 1.333 Ω
Rth = (R1 ∥ R2) + R3 = 1.333 + 12 = 13.33 Ω
Find Vth, the open-circuit voltage
With a–b open, no current flows through R₃, so there is no drop across it and V_b = V_A. R₁ and R₂ form a voltage divider.
Vth = V1·R2/(R1+R2) = 12·4/(2+4) = 8 V
6.Thévenin & Norton
Answer: Vth = −8.273 V
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 8·25/(8+25) = 6.061 Ω
Rth = (R1 ∥ R2) + R3 = 6.061 + 4 = 10.06 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 6.818 + (−1.5)·6.061 = −2.273 V
Vth = VB = VA + Is·R3 = −2.273 + (−1.5)·4 = −8.273 V
7.RC & RL transients
Answer: i = 0.06725 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·100 = 628.3 rad/s
C = 1/(ω₀²·L) = 1/(628.3²·0.002) = 1267 µF
Answer
C = 1267 µF
10.AC impedance & phasors
Answer: f0 = 232.2 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Current
|Z| = √(8² + 6²) = 10 Ω
I = V/|Z| = 230/10 = 23 A
Real power
P = I²·R = 23²·8 = 4232 W
Answer
P = 4232 W
12.AC power & power factor
Answer: C = 88.42 µF
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Conjugate match
The load reactance cancels the source reactance, and the load resistance equals the source resistance.
ZL = Zs* = 50 − j30 Ω
Capacitance
XC = 30 Ω → C = 1/(2π·60·30) = 88.42 µF
Answer
C = 88.42 µF
13.Three-phase power
Answer: P = 15.29 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 415 V
Phase current
|Z| = √(5² + 12²) = 13 Ω
Iph = 415/13 = 31.92 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·31.92²·5 = 15.29 kW
Answer
P = 15.29 kW
Check: cos φ = R/|Z| = 0.3846, and √3·VL·IL·cos φ gives the same power.
14.Three-phase power
Answer: Cph = 289.8 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 150·tan(acos 0.78) = 150·0.8023 = 120.3 kvar
Q2 = 150·tan(acos 0.92) = 150·0.426 = 63.9 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 56.44 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 415 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 18814/(377·415²) = 289.8 µF
Answer
Cph = 289.8 µF
15.Transformers
Answer: ILV = 125 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Rated current
Both windings carry the same apparent power.
ILV = S/V = 50000/400 = 125 A
Answer
ILV = 125 A
16.Transformers
Answer: Sη,max = 17.68 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.