The inductor carries no current before the switch closes at t = 0. Find the energy W stored in the inductor at t = 15 ms, in mJ.
Vs = 20 VR = 33 ΩL = 220 mHt = 15 ms
W = mJ
8.RC & RL transientsHard
The switch has been closed for a long time, so the circuit is in steady state. At t = 0 the switch opens. Find the capacitor voltage vC at t = 120 ms.
Vs = 12 VR1 = 2.2 kΩR2 = 2.2 kΩC = 68 µFt = 120 ms
vC = V
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 100 V (rms), 500 Hz supply. Find the rms current I.
V = 100 V (rms)f = 500 HzR = 80 ΩL = 20 mHC = 4.7 µF
I = A
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 100 V (rms), 500 Hz supply. Find the resonant frequency f0 of the circuit.
V = 100 V (rms)f = 500 HzR = 25 ΩL = 100 mHC = 10 µF
f0 = Hz
11.AC power & power factorMedium
A single-phase motor takes 1 kW at a power factor of 0.6 lagging from a 400 V supply. Find the line current I.
P = 1 kWpf = 0.6V = 400 V
I = A
12.AC power & power factorHard
A single-phase load takes 20 kW at a power factor of 0.75 lagging from a 400 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.
P = 20 kWpf1 = 0.75pf2 = 0.92V = 400 Vf = 50 Hz
Inew = A
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 10 A from a supply with a line-to-line voltage of 208 V. The power factor is 0.95 lagging. Find the total real power P drawn by the load in kW.
VL = 208 VIL = 10 Acos φ = 0.95
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 80 kW at a power factor of 0.75 lagging from a 400 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 80 kWpf1 = 0.75pf2 = 0.92VL = 400 Vf = 60 Hz
QC = kvar
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 4:1 has 960 V applied to its primary winding. A 20 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 4:1V1 = 960 VRL = 20 Ω
I1 = A
16.TransformersHard
A single-phase 50 kVA transformer has a core loss of 150 W and a copper loss of 375 W at rated load. It supplies 50% of its rated kVA at a power factor of 0.8 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 4 + 12 = 16 Ω
R2 ∥ 16 = 4·16/(4+16) = 3.2 Ω
Req = R1 + 3.2 = 5 + 3.2 = 8.2 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 18/8.2 = 2.195 A
Answer
IR1 = 2.195 A
2.Series & parallel resistors
Answer: IR1 = 0.7911 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 5 + 6 = 11 Ω
R4 ∥ 11 = 7.639 Ω
R3 + 7.639 = 13.64 Ω
R2 ∥ 13.64 = 9.376 Ω
Req = R1 + 9.376 = 2 + 9.376 = 11.38 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 9/11.38 = 0.7911 A
Answer
IR1 = 0.7911 A
3.Nodal analysis
Answer: PIs = 116.3 W
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/2 + (VA − 12)/2 + (VA − VB)/4 = 0
1.25·VA − 0.25·VB = 6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/15 + (VB − VA)/4 = 5
−0.25·VA + 0.3167·VB = 5
Solve
Δ = (1.25)(0.3167) − (−0.25)(−0.25) = 0.3333
VA = Δ1/Δ = 3.15/0.3333 = 9.45 V
VB = Δ2/Δ = 7.75/0.3333 = 23.25 V
Power delivered by the current source
The source pushes Iₛ up into node B, from ground (0 V) to VB. A source whose current leaves its + end delivers P = V·I.
PIs = VB·Is = 23.25·5 = 116.3 W
Answer
PIs = 116.3 W
4.Nodal analysis
Answer: IR1 = 0.9454 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 9 V, V2 = −36 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/5 + (VA − 9)/25 + (VA − VB)/6 = 0
0.4067·VA − 0.1667·VB = 0.36
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 6·4/(6+4) = 2.4 Ω
Rth = (R1 ∥ R2) + R3 = 2.4 + 20 = 22.4 Ω
6.Thévenin & Norton
Answer: PL = 4.373 W
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 10·8/(10+8) = 4.444 Ω
Rth = (R1 ∥ R2) + R3 = 4.444 + 30 = 34.44 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 2.222 + 1.5·4.444 = 8.889 V
Vth = VB = VA + Is·R3 = 8.889 + 1.5·30 = 53.89 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 53.89/(34.44 + 2) = 1.479 A
PL = IL²·RL = 1.479²·2 = 4.373 W
7.RC & RL transients
Answer: W = 32.34 mJ
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
τ = L/R = 220 mH / 33 Ω = 6.667 ms
i(∞) = Vs/R = 20/33 = 0.6061 A
Current at the given time
i(t) = 0.6061·(1 − e−15/6.667) = 0.5422 A
Stored energy
W = ½·L·i² = ½·220·0.5422² = 32.34 mJ
Answer
W = 32.34 mJ
8.RC & RL transients
Answer: vC = 2.69 V
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial capacitor voltage
In steady state the capacitor is an open circuit, so R₁ and R₂ form a voltage divider. The capacitor voltage cannot jump when the switch opens.
vC(0) = 12·2.2/(2.2 + 2.2) = 6 V
Time constant after the switch opens
τ = R2·C = 2.2·68 = 149.6 ms
Discharge
vC(t) = 6·e−120/149.6 = 2.69 V
Answer
vC = 2.69 V
9.AC impedance & phasors
Answer: I = 1.248 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·500 = 3142 rad/s
XL = ωL = 3142·0.02 = 62.83 Ω
XC = 1/(ωC) = 1/(3142·4.7·10⁻⁶) = 67.73 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 100/80.15 = 1.248 A
Answer
I = 1.248 A
10.AC impedance & phasors
Answer: f0 = 159.2 Hz
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Line current
Only the real part of the power does work, so divide by the power factor.
I = P/(V·cos φ) = 1000/(400·0.6) = 4.167 A
Answer
I = 4.167 A
12.AC power & power factor
Answer: Inew = 54.35 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 20·tan(41.41°) = 17.64 kvar
Q2 = P·tan φ2 = 20·tan(23.07°) = 8.52 kvar
QC = Q1 − Q2 = 9.118 kvar
New line current
Inew = P/(V·cos φ2) = 20000/(400·0.92) = 54.35 A
Answer
Inew = 54.35 A
13.Three-phase power
Answer: P = 3.423 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·208·10 = 3.603 kVA
Real power
P = S·cos φ = 3.603·0.95 = 3.423 kW
Answer
P = 3.423 kW
14.Three-phase power
Answer: QC = 36.47 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 80·tan(acos 0.75) = 80·0.8819 = 70.55 kvar
Q2 = 80·tan(acos 0.92) = 80·0.426 = 34.08 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 36.47 kvar
Answer
QC = 36.47 kvar
15.Transformers
Answer: I1 = 3 A
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 960/4 = 240 V
I2 = 240/20 = 12 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/4 = 3 A
Answer
I1 = 3 A
Check: the load seen from the primary is a²·RL = 320 Ω, and 960/320 gives the same current.
16.Transformers
Answer: Ploss = 243.8 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.