The diamond is a voltage-controlled current source that pushes a current of 0.05·VA (in A, with VA in V) up into node B. Use nodal analysis to find the node voltage VA (measured from ground).
The inductor carries no current before the switch closes at t = 0. Find the current i at t = 1 ms.
Vs = 20 VR = 33 ΩL = 22 mHt = 1 ms
i = A
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 3 V with the polarity shown. How long does it take for vC to reach 8.1 V? Find t.
Vs = 20 VR = 6.8 kΩC = 68 µFvC(0) = 3 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 230 V (rms), 50 Hz supply. Find the power factor cos φ of the circuit.
V = 230 V (rms)f = 50 HzR = 25 ΩL = 100 mHC = 47 µF
cos φ =
10.AC impedance & phasorsHard
A series RLC circuit is connected to a 10 V (rms), 100 Hz supply. Find the rms current I.
V = 10 V (rms)f = 100 HzR = 30 ΩL = 150 mHC = 100 µF
I = A
11.AC power & power factorMedium
An inductive load takes 10.5 A and 1449 W from a 230 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.
V = 230 VI = 10.5 AP = 1449 W
R = Ω
12.AC power & power factorHard
A single-phase load takes 50 kW at a power factor of 0.65 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.95. Find the reactive power QC the capacitor must supply.
P = 50 kWpf1 = 0.65pf2 = 0.95V = 230 Vf = 50 Hz
QC = kvar
13.Three-phase powerMedium
A three-phase induction motor delivers 30 kW of mechanical output power at full load. At this load its efficiency is 94% and its power factor is 0.85 lagging. The supply has a line-to-line voltage of 415 V. Find the line current IL.
Pout = 30 kWη = 94%cos φ = 0.85VL = 415 V
IL = A
14.Three-phase powerHard
A balanced three-phase load takes 50 kW at a power factor of 0.7 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 50 kWpf1 = 0.7pf2 = 0.98VL = 415 Vf = 50 Hz
Cph = µF
15.TransformersMedium
An ideal transformer with a turns ratio N₁:N₂ = 10:1 has 2400 V applied to its primary winding. A 40 Ω resistor is connected across the secondary winding. Find the primary current I1.
N1:N2 = 10:1V1 = 2400 VRL = 40 Ω
I1 = A
16.TransformersHard
A single-phase 500 kVA transformer has a core loss of 2000 W and a copper loss of 4000 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 500 kVAPcore = 2000 WPcu,fl = 4000 W
Sη,max = kVA
3Solutions
1.Series & parallel resistors
Answer: IR2 = 1.191 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 4 + 15 = 19 Ω
R2 ∥ 19 = 5·19/(5+19) = 3.958 Ω
Req = R1 + 3.958 = 12 + 3.958 = 15.96 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 24/15.96 = 1.504 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 24 − 1.504·12 = 5.953 V
IR2 = VA/R2 = 5.953/5 = 1.191 A
Answer
IR2 = 1.191 A
2.Series & parallel resistors
Answer: IR1 = 3.104 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 10 = 18 Ω
R4 ∥ 18 = 3.913 Ω
R3 + 3.913 = 7.913 Ω
R2 ∥ 7.913 = 1.596 Ω
Req = R1 + 1.596 = 10 + 1.596 = 11.6 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 36/11.6 = 3.104 A
Answer
IR1 = 3.104 A
3.Nodal analysis
Answer: VB = 18.12 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/6 + (VA − 24)/15 + (VA − VB)/2 = 0
0.7333·VA − 0.5·VB = 1.6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/15 + (VB − VA)/2 = 3
−0.5·VA + 0.5667·VB = 3
Solve
Δ = (0.7333)(0.5667) − (−0.5)(−0.5) = 0.1656
VA = Δ1/Δ = 2.407/0.1656 = 14.54 V
VB = Δ2/Δ = 3/0.1656 = 18.12 V
Answer
VB = 18.12 V
4.Nodal analysis
Answer: VA = 15.81 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
(VA − V1)/R1 + VA/R2 + (VA − VB)/R3 = 0
0.2667·VA − 0.06667·VB = 4
KCL at node B
The dependent source pushes g·VA into node B. Treat it like an independent source, then move the VA term to the left-hand side.
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 12·10/(12+10) = 5.455 Ω
Rth = (R1 ∥ R2) + R3 = 5.455 + 3 = 8.455 Ω
6.Thévenin & Norton
Answer: IL = 0.4741 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 25·6/(25+6) = 4.839 Ω
Rth = (R1 ∥ R2) + R3 = 4.839 + 20 = 24.84 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 1.161 + 1·4.839 = 6 V
Vth = VB = VA + Is·R3 = 6 + 1·20 = 26 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 26/(24.84 + 30) = 0.4741 A
7.RC & RL transients
Answer: i = 0.4708 A
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Time constant and final current
Long after the switch closes the inductor behaves like a short circuit, so the final current is set by R alone.
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((3 − 20)/(8.1 − 20)) = 462.4·ln(1.429) = 164.9 ms
Answer
t = 164.9 ms
9.AC impedance & phasors
Answer: cos φ = 0.5671
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 31.42 Ω, XC = 67.73 Ω
Impedance
|Z| = √(25² + (−36.31)²) = 44.08 Ω
Power factor
cos φ = R/|Z| = 25/44.08 = 0.5671
The circuit is capacitive, so the power factor is leading.
Answer
cos φ = 0.5671
10.AC impedance & phasors
Answer: I = 0.1192 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
ω = 2πf = 2π·100 = 628.3 rad/s
XL = ωL = 628.3·0.15 = 94.25 Ω
XC = 1/(ωC) = 1/(628.3·100·10⁻⁶) = 15.92 Ω
Impedance
In series the impedances add as complex numbers: Z = R + j(XL − XC).
The same current flows through every element of a series circuit.
I = V/|Z| = 10/83.88 = 0.1192 A
Answer
I = 0.1192 A
11.AC power & power factor
Answer: R = 13.14 Ω
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 1449/10.5² = 13.14 Ω
Answer
R = 13.14 Ω
12.AC power & power factor
Answer: QC = 42.02 kvar
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 50·tan(49.46°) = 58.46 kvar
Q2 = P·tan φ2 = 50·tan(18.19°) = 16.43 kvar
QC = Q1 − Q2 = 42.02 kvar
Answer
QC = 42.02 kvar
13.Three-phase power
Answer: IL = 52.24 A
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Electrical input power
Pin = Pout/η = 30/0.94 = 31.91 kW
Line current
IL = Pin/(√3·VL·cos φ) = 31915/(√3·415·0.85) = 52.24 A
Answer
IL = 52.24 A
14.Three-phase power
Answer: Cph = 251.7 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 50·tan(acos 0.7) = 50·1.02 = 51.01 kvar
Q2 = 50·tan(acos 0.98) = 50·0.2031 = 10.15 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 40.86 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Secondary voltage and current
V2 = 2400/10 = 240 V
I2 = 240/40 = 6 A
Primary current
An ideal transformer has no losses: V₁·I₁ = V₂·I₂.
I1 = I2/10 = 0.6 A
Answer
I1 = 0.6 A
Check: the load seen from the primary is a²·RL = 4000 Ω, and 2400/4000 gives the same current.
16.Transformers
Answer: Sη,max = 353.6 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.