The source Vₛ charges the capacitor through R₁, and R₂ is connected in parallel with C. The capacitor is uncharged when the switch closes at t = 0. Find the time constant τ of the circuit after the switch closes.
Vs = 30 VR1 = 6.8 kΩR2 = 3.3 kΩC = 10 µF
τ = ms
8.RC & RL transientsHard
Just before the switch closes at t = 0, the capacitor holds 12 V with the polarity shown. How long does it take for vC to reach 15.6 V? Find t.
Vs = 24 VR = 10 kΩC = 22 µFvC(0) = 12 V
t = ms
9.AC impedance & phasorsMedium
A series RLC circuit is connected to a 230 V (rms), 50 Hz supply. Find the real power P taken from the supply.
V = 230 V (rms)f = 50 HzR = 25 ΩL = 20 mHC = 100 µF
P = W
10.AC impedance & phasorsHard
A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 230 V (rms), 100 Hz supply. Find the magnitude of the impedance |Z|.
V = 230 V (rms)f = 100 HzR1 = 15 ΩR2 = 20 ΩC = 22 µF
|Z| = Ω
11.AC power & power factorMedium
An inductive load takes 10.5 A and 1691 W from a 230 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.
V = 230 VI = 10.5 AP = 1691 W
X = Ω
12.AC power & power factorHard
A single-phase load takes 18 kW at a power factor of 0.7 lagging from a 400 V, 60 Hz supply. A 68 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.
P = 18 kWpf1 = 0.7V = 400 Vf = 60 HzC = 68 µF
cos φ =
13.Three-phase powerMedium
A balanced three-phase load draws a line current of 50 A from a supply with a line-to-line voltage of 415 V. The power factor is 0.85 lagging. Find the total real power P drawn by the load in kW.
VL = 415 VIL = 50 Acos φ = 0.85
P = kW
14.Three-phase powerHard
A balanced three-phase load takes 120 kW at a power factor of 0.75 lagging from a 415 V (line-to-line), 60 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.98 lagging. The real power stays the same. The capacitors are connected in Δ. Find the capacitance Cph of each capacitor in µF.
P = 120 kWpf1 = 0.75pf2 = 0.98VL = 415 Vf = 60 Hz
Cph = µF
15.TransformersMedium
A 5 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 12:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 12:1RL = 5 Ω
R1′ = Ω
16.TransformersHard
A single-phase 100 kVA transformer has a core loss of 500 W and a copper loss of 1250 W at rated load. It supplies 75% of its rated kVA at a power factor of 0.85 lagging. Find the total losses Ploss in watts at this load.
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R3 + R4 = 5 + 6 = 11 Ω
R2 ∥ 11 = 20·11/(20+11) = 7.097 Ω
Req = R1 + 7.097 = 15 + 7.097 = 22.1 Ω
Answer
Req = 22.1 Ω
2.Series & parallel resistors
Answer: IR2 = 0.2711 A
Series and parallel resistors: in series the same current flows through each resistor and R = R₁ + R₂ + …. In parallel each resistor has the same voltage and 1/R = 1/R₁ + 1/R₂ + …. A ladder network is reduced one pair at a time until a single equivalent resistance remains.
Combine resistors from the far end
Start at the end farthest from the source and work back towards it. Resistors carrying the same current are in series; resistors across the same two nodes are in parallel.
R5 + R6 = 8 + 6 = 14 Ω
R4 ∥ 14 = 3.684 Ω
R3 + 3.684 = 5.684 Ω
R2 ∥ 5.684 = 3.857 Ω
Req = R1 + 3.857 = 8 + 3.857 = 11.86 Ω
Current from the source
The source sees only Req, so Ohm’s law gives the current it delivers. That current flows through R₁.
IR1 = V1/Req = 10/11.86 = 0.8434 A
Current through R₂
Subtract the drop across R₁ to get the voltage at node A, which is the voltage across R₂.
VA = V1 − IR1·R1 = 10 − 0.8434·8 = 3.253 V
IR2 = VA/R2 = 3.253/12 = 0.2711 A
Answer
IR2 = 0.2711 A
3.Nodal analysis
Answer: VA = 21.25 V
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 24 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R2 + (VA − V1)/R1 + (VA − VB)/R3 = 0
VA/10 + (VA − 24)/4 + (VA − VB)/10 = 0
0.45·VA − 0.1·VB = 6
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R4 + (VB − VA)/R3 = Is
VB/10 + (VB − VA)/10 = 5
−0.1·VA + 0.2·VB = 5
Solve
Δ = (0.45)(0.2) − (−0.1)(−0.1) = 0.08
VA = Δ1/Δ = 1.7/0.08 = 21.25 V
VB = Δ2/Δ = 2.85/0.08 = 35.63 V
Answer
VA = 21.25 V
4.Nodal analysis
Answer: IR1 = 0.7546 A
Nodal analysis: choose a reference node, label the unknown node voltages, write Kirchhoff’s current law at each unknown node using Ohm’s law (I = ΔV/R), and solve the resulting equations.
Set up the nodes
Ground is the bottom wire. Known node voltages come straight from the sources (V1 = 36 V, V2 = 5 V). Unknowns: VA, VB.
KCL at node A
Currents leaving A through the resistors equal the current pushed into A by sources.
VA/R3 + (VA − V1)/R1 + (VA − VB)/R2 = 0
VA/20 + (VA − 36)/8 + (VA − VB)/6 = 0
0.3417·VA − 0.1667·VB = 4.5
KCL at node B
Currents leaving B through the resistors equal the current pushed into B by sources.
VB/R5 + (VB − VA)/R2 + (VB − V2)/R4 = Is
VB/15 + (VB − VA)/6 + (VB − 5)/15 = 5
−0.1667·VA + 0.3·VB = 5.333
Solve
Δ = (0.3417)(0.3) − (−0.1667)(−0.1667) = 0.07472
VA = Δ1/Δ = 2.239/0.07472 = 29.96 V
VB = Δ2/Δ = 2.572/0.07472 = 34.42 V
Answer
IR1 = (V1 − VA)/R1 = (36 − 29.96)/8 = 0.7546 A
5.Thévenin & Norton
Answer: Rth = 10.61 Ω
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 3·20/(3+20) = 2.609 Ω
Rth = (R1 ∥ R2) + R3 = 2.609 + 8 = 10.61 Ω
6.Thévenin & Norton
Answer: IL = 0.3369 A
Thévenin’s theorem: any linear two-terminal network behaves like a single voltage source Vth in series with a resistance Rth. Norton’s theorem gives the same network as a current source IN = Vth/Rth in parallel with Rth.
Find Rth with every source switched off
Replace voltage sources with shorts and current sources with opens, then look into the circuit from a–b.
R1 ∥ R2 = 30·2/(30+2) = 1.875 Ω
Rth = (R1 ∥ R2) + R3 = 1.875 + 8 = 9.875 Ω
Find Vth, the open-circuit voltage
With a–b open, the only path for Iₛ is through R₃ into node A. Find V_A by superposition of V₁ and Iₛ, then add the drop across R₃.
VA = V1·R2/(R1+R2) + Is·(R1∥R2) = 1.875 + 1·1.875 = 3.75 V
Vth = VB = VA + Is·R3 = 3.75 + 1·8 = 11.75 V
Connect the load to the Thévenin equivalent
The Thévenin source and R_th in series behave exactly like the original circuit at a–b, so the load sees a simple series loop.
IL = Vth/(Rth + RL) = 11.75/(9.875 + 25) = 0.3369 A
7.RC & RL transients
Answer: τ = 22.22 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Thévenin equivalent seen by the capacitor
Short the source to find Rth; open the capacitor to find the voltage it will settle at.
Rth = R1 ∥ R2 = 6.8·3.3/(6.8 + 3.3) = 2.222 kΩ
vC(∞) = 30·3.3/(6.8 + 3.3) = 9.802 V
Time constant
τ = Rth·C = 2.222·10 = 22.22 ms
Answer
τ = 22.22 ms
8.RC & RL transients
Answer: t = 78.47 ms
First-order transients: in a circuit with one capacitor or one inductor, every voltage and current moves exponentially from its initial value to its final value: x(t) = x(∞) + [x(0) − x(∞)]·e−t/τ, with τ = RC or τ = L/R. After about 5τ the circuit has settled.
Initial value, final value, time constant
The capacitor voltage cannot jump, so it starts at its stored value and heads for the source voltage.
t = τ·ln((12 − 24)/(15.6 − 24)) = 220·ln(1.429) = 78.47 ms
Answer
t = 78.47 ms
9.AC impedance & phasors
Answer: P = 1035 W
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactances
XL = 6.283 Ω, XC = 31.83 Ω
Impedance
|Z| = √(25² + (−25.55)²) = 35.74 Ω
Real power
Inductors and capacitors only store and return energy; the resistor absorbs all of the real power.
I = 230/35.74 = 6.435 A
P = I²·R = 6.435²·25 = 1035 W
Answer
P = 1035 W
10.AC impedance & phasors
Answer: |Z| = 33.97 Ω
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(2π·100·22·10⁻⁶) = 72.34 Ω
Parallel combination
Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Resistance from the real power
R = P/I² = 1691/10.5² = 15.34 Ω
Reactance from the impedance
|Z| = V/I = 230/10.5 = 21.9 Ω
X = √(|Z|² − R²) = √(21.9² − 15.34²) = 15.64 Ω
Answer
X = 15.64 Ω
12.AC power & power factor
Answer: cos φ = 0.7838
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = 18·tan(arccos 0.7) = 18.36 kvar
QC = V²·2πf·C = 400²·2π·60·68·10⁻⁶ = 4102 var = 4.102 kvar
Q2 = 18.36 − 4.102 = 14.26 kvar
New apparent power
S2 = √(18² + 14.26²) = 22.97 kVA
New power factor
cos φ = P/S2 = 18/22.97 = 0.7838
Answer
cos φ = 0.7838
13.Three-phase power
Answer: P = 30.55 kW
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Apparent power
S = √3·VL·IL = √3·415·50 = 35.94 kVA
Real power
P = S·cos φ = 35.94·0.85 = 30.55 kW
Answer
P = 30.55 kW
14.Three-phase power
Answer: Cph = 418.2 µF
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 120·tan(acos 0.75) = 120·0.8819 = 105.8 kvar
Q2 = 120·tan(acos 0.98) = 120·0.2031 = 24.37 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 81.46 kvar
Capacitance per phase
In a Δ bank each capacitor is connected between two lines.
V = 415 V, ω = 2π·60 = 377 rad/s
Cph = (QC/3)/(ω·V²) = 27154/(377·415²) = 418.2 µF
Answer
Cph = 418.2 µF
15.Transformers
Answer: R1′ = 720 Ω
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 12²·5 = 720 Ω
Answer
R1′ = 720 Ω
16.Transformers
Answer: Ploss = 1203 W
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.