Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 30% NaOH? Find ṁ2.
An evaporator concentrates a NaOH solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot glycol mix cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot glycol mix heats water in an exchanger that loses 15% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
What volume V does 140 g of O₂ occupy at 500 kPa and 5 °C? Treat it as an ideal gas.
Find the density ρ of O₂ at 550 kPa and 200 °C, treating it as an ideal gas.
6 g of C3H8 and 40 g of O2 react according to C3H8 + 5O2 → 3CO2 + 4H2O. What mass m of CO2 can form?
In the reaction Fe2O3 + 3CO → 2Fe + 3CO2, 12 g of Fe2O3 reacts completely (the other reactants are in excess) and 6.15 g of CO2 is collected. Find the percent yield Y.
0.5 mol/L of H₂ and 0.5 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 16. Find the equilibrium concentration [H2].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.5 at the reaction temperature. A container starts with 0.1 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 250 g block of iron (c = 0.449 J/(g·°C)) at 180 °C is dropped into 400 g of water (c = 4.18 J/(g·°C)) at 22 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 50 g of C4H10 (M = 58.12 g/mol) burns completely: 2C4H10 + 13O₂ → 8CO₂ + 10H₂O(l). Give q as a positive number.
A reaction with rate law −rA = k·CA² has k = 0.8 L/(mol·min) and starts at 1 mol/L. Find the concentration CA after 5 min.
Two experiments measure the initial rate of A → products. With CA0 = 0.5 mol/L the rate is 0.02 mol/(L·s); with CA0 = 2 mol/L it is 1.28 mol/(L·s). Find the reaction order n with respect to A.
A first-order liquid-phase reaction must reach 95% conversion. How many times larger must a CSTR be than a PFR for the same feed rate, rate constant and conversion? Find the ratio VCSTR/VPFR.
A first-order liquid-phase reaction (k = 0.05 min⁻¹) runs in a 500 L CSTR fed at 40 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A counter-flow heat exchanger transfers 20 kW. The hot fluid cools from 140 to 80 °C and the cold fluid heats from 25 to 60 °C. The overall heat transfer coefficient is 200 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow double-pipe heat exchanger, hot oil (0.8 kg/s, cp = 2.5 kJ/(kg·K)) flows in the inner tube and cools from 145 to 75 °C. Water (1.5 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 15 °C. The inner tube has a diameter of 50 mm, and U = 500 W/(m²·K) is based on this diameter. Find the tube length L needed.
A wall is made of 250 mm of glass and 25 mm of brick, with an area of 20 m². The outer faces are at 22 °C and 9 °C. Find the heat flow Q̇ through the wall.
A wall of 200 mm gypsum board and 100 mm brick separates a room at 22 °C from outside air at -3 °C. The convection coefficients are 7.7 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 4 m². Find the overall heat transfer coefficient U of the wall.
Water flows at a mean velocity of 2.9 m/s through a pipe 50 m long with an inside diameter of 200 mm. Use the Darcy friction factor f = 0.028 and g = 9.81 m/s². Find the friction head loss hf.
Two open reservoirs are joined by a pipe 300 m long with an inside diameter of 250 mm and a Darcy friction factor f = 0.02. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each), a valve (K = 2) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². What difference in water level Δz between the reservoirs gives a flow rate of 75 L/s?
A pump with an efficiency of 85% delivers 80 L/s of water (ρ = 1000 kg/m³) against a head of 74 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 40 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 5 m higher. The pipe is 400 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.02; the minor-loss coefficients add up to ΣK = 6 (entrance and exit included). Use g = 9.81 m/s². The upper tank is closed and the air above its water is at a gauge pressure of 350 kPa. Find the head H the pump must add.
Answer: ṁ2 = 500 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 3600 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 118.3 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 1.098 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: V = 20.23 L
Ideal gas law: PV = nRT, with n = m/M.
Answer: ρ = 4.474 kg/m³
Ideal gas density: ρ = PM/(RT).
Answer: m = 17.96 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 61.99 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [H2] = 0.1667 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.08541 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 31.94 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 2475 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: CA = 0.2 mol/L
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: n = 3
Method of initial rates: for r = k·Cⁿ, comparing two runs that differ only in the starting concentration removes k: r₂/r₁ = (C₂/C₁)ⁿ. Doubling C doubles the rate for first order and quadruples it for second order.
Answer: VCSTR/VPFR = 6.342
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
The gap grows quickly at high conversion.
Answer: X = 38.46 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 1.499 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: L = 21.86 m
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 880.9 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: U = 0.6763 W/(m²·K)
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 3.001 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Δz = 3.415 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Pshaft = 68.32 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 44.48 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are practically at rest, so there is no velocity head term.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical