Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 40% salt? Find ṁ2.
An evaporator concentrates a NaOH solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot glycol mix cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot glycol mix heats water in an exchanger that loses 15% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
What volume V does 470 g of CH₄ occupy at 500 kPa and 90 °C? Treat it as an ideal gas.
Find the density ρ of CO₂ at 850 kPa and 30 °C, treating it as an ideal gas.
16 g of C3H8 and 80 g of O2 react according to C3H8 + 5O2 → 3CO2 + 4H2O. What mass m of H2O can form?
In the reaction C3H8 + 5O2 → 3CO2 + 4H2O, 10 g of C3H8 reacts completely (the other reactants are in excess) and 18.56 g of CO2 is collected. Find the percent yield Y.
0.25 mol/L of H₂ and 0.25 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 25. Find the equilibrium concentration [H2].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.08 at the reaction temperature. A container starts with 1 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 200 g block of lead (c = 0.129 J/(g·°C)) at 200 °C is dropped into 400 g of water (c = 4.18 J/(g·°C)) at 16 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 250 g of C2H6 (M = 30.07 g/mol) burns completely: 2C2H6 + 7O₂ → 4CO₂ + 6H₂O(l). Give q as a positive number.
A second-order reaction (−rA = k·CA²) in a batch reactor has k = 0.05 L/(mol·min) and starts at 1.5 mol/L. How long does it take to reach 50% conversion? Find t.
A reaction has a rate constant of 0.05 min⁻¹ at 35 °C and an activation energy of 60 kJ/mol. Find the rate constant k2 at 60 °C.
A liquid-phase first-order reaction A → B (k = 0.3 min⁻¹) runs in a 50 L plug-flow reactor (PFR). The feed enters at 10 L/min with CA0 = 0.5 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.
A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in a 1000 L CSTR fed at 25 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A counter-flow heat exchanger transfers 120 kW. The hot fluid cools from 150 to 50 °C and the cold fluid heats from 15 to 55 °C. The overall heat transfer coefficient is 1000 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow heat exchanger both streams have the same heat capacity rate, ṁ·cp = 1.5 kW/K. The hot stream enters at 125 °C and the cold stream at 20 °C. The exchanger has A = 1.5 m² and U = 500 W/(m²·K). Find the hot outlet temperature Th,out.
A wall is made of 100 mm of concrete and 75 mm of brick, with an area of 4 m². The outer faces are at 15 °C and -9 °C. Find the temperature Ti at the interface between the two layers.
A wall of 200 mm glass and 100 mm wood separates a room at 20 °C from outside air at 4 °C. The convection coefficients are 7.7 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 4 m². Find the temperature Ts of the inside surface of the wall.
Water (ρ = 1000 kg/m³) flows at 2.8 m/s through a horizontal pipe, 300 m long, with an inside diameter of 200 mm. Use the Darcy friction factor f = 0.028 and g = 9.81 m/s². Find the pressure drop Δp over the pipe in kPa.
Two open reservoirs are joined by a pipe 200 m long with an inside diameter of 250 mm and a Darcy friction factor f = 0.018. The minor losses are a square-edged entrance (K = 0.5), 3 bends (K = 0.3 each), a valve (K = 0.2) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². What difference in water level Δz between the reservoirs gives a flow rate of 100 L/s?
A pump with an efficiency of 80% delivers 50 L/s of water (ρ = 1000 kg/m³) against a head of 32 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 80 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 9 m higher. The pipe is 600 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.015; the minor-loss coefficients add up to ΣK = 6 (entrance and exit included). Use g = 9.81 m/s². The upper tank is closed and the air above its water is at a gauge pressure of 350 kPa. Find the head H the pump must add.
Answer: ṁ2 = 180 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 2222 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 34.35 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 2.196 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: V = 176.9 L
Ideal gas law: PV = nRT, with n = m/M.
Answer: ρ = 14.84 kg/m³
Ideal gas density: ρ = PM/(RT).
Answer: m = 26.15 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 61.99 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [H2] = 0.07143 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.7543 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 18.8 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 12967 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: t = 13.33 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: k2 = 0.2899 min⁻¹
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: CA = 0.1116 mol/L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Conversion: X = 77.69%.
Answer: X = 90.91 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 1.997 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Th,out = 90 °C
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
The cold outlet sits opposite the hot inlet: Tc,out = Tc,in + (Th,in − Th,out), so ΔT₁ = Th,in − Tc,out = Th,out − Tc,in = ΔT₂.
Heat transferred: Q̇ = 52.5 kW; the cold stream leaves at 55 °C.
Answer: Ti = 5.237 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
The temperature drops across the first layer by Q̇·R₁.
Answer: Ts = 17.83 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Δp = 164.6 kPa
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The pipe is horizontal and the velocity does not change, so the energy equation reduces to Δp = ρ·g·hf.
Answer: Δz = 3.596 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Pshaft = 19.62 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 61.53 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are practically at rest, so there is no velocity head term.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical