Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 30% salt? Find ṁ2.
An evaporator concentrates a salt solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot glycol mix heats water in an exchanger that loses 10% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 10 L contains 90 g of O₂ at 20 °C. Treat it as an ideal gas and find the pressure P.
A fixed amount of N₂ goes from 250 kPa, 2 L, 15 °C to 650 kPa and 190 °C. Find the new volume V2.
24 g of Mg and 80 g of O2 react according to 2Mg + O2 → 2MgO. What mass m of MgO can form?
In the reaction 2Mg + O2 → 2MgO, 10 g of Mg reacts completely (the other reactants are in excess) and 15.58 g of MgO is collected. Find the percent yield Y.
0.4 mol/L of H₂ and 0.4 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 36. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.01 at the reaction temperature. A container starts with 0.2 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 200 g block of iron (c = 0.449 J/(g·°C)) at 120 °C is dropped into 150 g of water (c = 4.18 J/(g·°C)) at 22 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 50 g of CH4 (M = 16.04 g/mol) burns completely: CH4 + 2O₂ → CO₂ + 2H₂O(l). Give q as a positive number.
A second-order reaction (−rA = k·CA²) has k = 1 L/(mol·min) and an initial concentration of 0.5 mol/L. Find its first half-life t½.
A first-order reaction has k = 0.01 min⁻¹ at 20 °C and an activation energy of 75 kJ/mol. The batch reactor is now run at 30 °C for 20 min. Find the conversion X reached.
A first-order liquid-phase reaction A → B with k = 0.15 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 80 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 90% conversion of A.
A first-order liquid-phase reaction (k = 0.1 min⁻¹) runs in a 200 L plug-flow reactor (PFR) fed at 10 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A shell-and-tube heat exchanger (one shell pass, two tube passes) must transfer 720 kW. The hot fluid cools from 105 to 80 °C and the cold fluid heats from 25 to 80 °C. The LMTD correction factor for this arrangement is F = 0.9, and U = 1000 W/(m²·K). Find the heat transfer area A needed.
Hot oil (1 kg/s, cp = 2.3 kJ/(kg·K)) cools from 85 to 60 °C in a counter-flow exchanger. It heats 1.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 25 °C. With U = 200 W/(m²·K), find the heat transfer area A needed.
A wall is made of 50 mm of gypsum board and 75 mm of expanded polystyrene, with an area of 12 m². The outer faces are at 20 °C and 8 °C. Find the heat flow Q̇ through the wall.
A wall of 200 mm glass and 75 mm expanded polystyrene separates a room at 20 °C from outside air at 4 °C. The convection coefficients are 10 W/(m²·K) inside and 25 W/(m²·K) outside, and the wall area is 4 m². Find the temperature Ts of the inside surface of the wall.
Water flows at 4 L/s through a pipe 150 m long with an inside diameter of 100 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the friction head loss hf.
A pipe 150 m long with an inside diameter of 200 mm (Darcy friction factor f = 0.018) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 3 bends (K = 0.3 each) and a valve (K = 5). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 40 L/s?
A pump with an efficiency of 70% delivers 60 L/s of water (ρ = 1000 kg/m³) against a head of 60 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 75 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 21 m higher. The pipe is 600 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.02; the minor-loss coefficients add up to ΣK = 8 (entrance and exit included). Use g = 9.81 m/s². Find the head H the pump must add.
Answer: ṁ2 = 425 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 1440 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 17.54 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 0.9966 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 685.5 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 1.236 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 39.79 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 93.98 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 0.6 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.16 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 34.28 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 2775 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: t½ = 2 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Each later half-life is twice as long, because C₀ has halved.
Answer: X = 42.42 %
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: V = 1228 L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: X = 86.47 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 21.03 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: A = 6.777 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 59.09 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Ts = 19.36 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 0.3569 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: H = 1.727 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: Pshaft = 50.45 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 40.75 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are open and practically at rest, so pressure and velocity terms drop out.
ExamProblems · examproblems.com/courses/fe-exam-chemical