Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 45% NaOH? Find ṁ2.
An evaporator concentrates a NaOH solution by boiling off pure water. Find the product flow P in kg/h.
Hot ethanol cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 5% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
What volume V does 420 g of N₂ occupy at 400 kPa and 15 °C? Treat it as an ideal gas.
A fixed amount of Ar goes from 400 kPa, 10 L, 35 °C to 500 kPa and 210 °C. Find the new volume V2.
10 g of H2 and 16 g of O2 react according to 2H2 + O2 → 2H2O. What mass m of H2O can form?
In the reaction N2 + 3H2 → 2NH3, 12 g of N2 reacts completely (the other reactants are in excess) and 8.02 g of NH3 is collected. Find the percent yield Y.
1 mol/L of H₂ and 1 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 49. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.08 at the reaction temperature. A container starts with 1 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 150 g block of zinc (c = 0.388 J/(g·°C)) at 100 °C is dropped into 100 g of water (c = 4.18 J/(g·°C)) at 16 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 25 g of CH3OH (M = 32.04 g/mol) burns completely: 2CH3OH + 3O₂ → 2CO₂ + 4H₂O(l). Give q as a positive number.
A zero-order reaction has k = 0.02 mol/(L·min) and starts at 1.5 mol/L. How long does it take to reach 60% conversion? Find t.
A reaction has an activation energy of 75 kJ/mol. At 40 °C it is too slow. To what temperature T2 (in °C) must it be heated to make it 5 times faster?
A first-order liquid-phase reaction A → B with k = 0.3 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 50 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 60% conversion of A.
A first-order liquid-phase reaction (k = 0.1 min⁻¹) runs in an 800 L CSTR fed at 25 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A counter-flow heat exchanger transfers 280 kW. Its heat transfer area is 8 m². The hot fluid cools from 155 to 135 °C and the cold fluid heats from 15 to 55 °C. Find the overall heat transfer coefficient U.
Hot oil (0.5 kg/s, cp = 2.5 kJ/(kg·K)) cools from 140 to 70 °C in a counter-flow exchanger. It heats 0.5 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 30 °C. With U = 1000 W/(m²·K), find the heat transfer area A needed.
A wall is made of 200 mm of concrete and 25 mm of expanded polystyrene, with an area of 15 m². The outer faces are at 17 °C and -5 °C. Find the temperature Ti at the interface between the two layers.
A wall of 250 mm gypsum board and 100 mm concrete separates a room at 22 °C from outside air at 5 °C. The convection coefficients are 6 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 8 m². Find the overall heat transfer coefficient U of the wall.
Water flows at a mean velocity of 2.2 m/s through a pipe 150 m long with an inside diameter of 50 mm. Use the Darcy friction factor f = 0.02 and g = 9.81 m/s². Find the friction head loss hf.
Two open reservoirs are joined by a pipe 100 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.015. The water surface of the upper reservoir is 21 m above that of the lower one. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each), a valve (K = 2) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². Find the flow rate Q in L/s.
A pump with an efficiency of 80% delivers 80 L/s of water (ρ = 1000 kg/m³) against a head of 48 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 75 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 25 m higher. The pipe is 100 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.025; the minor-loss coefficients add up to ΣK = 8 (entrance and exit included). Use g = 9.81 m/s². Find the head H the pump must add.
Answer: ṁ2 = 6800 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: P = 886.2 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 56.27 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 0.9545 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: V = 89.81 L
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 12.54 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 18.02 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 54.98 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 1.556 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.7543 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 26.27 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 566.8 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: t = 45 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: T2 = 58.53 °C
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: V = 152.7 L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: X = 76.19 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: U = 319.1 W/(m²·K)
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: A = 1.656 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Ti = 13.33 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
The temperature drops across the first layer by Q̇·R₁.
Answer: U = 0.574 W/(m²·K)
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 14.8 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Q = 182.6 L/s
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Both surfaces are open to the air and practically at rest, so all of Δz is lost in the pipe.
Answer: Pshaft = 47.09 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 30.95 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are open and practically at rest, so pressure and velocity terms drop out.
ExamProblems · examproblems.com/courses/fe-exam-chemical