Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 40% sugar? Find ṁ2.
An evaporator concentrates a NaOH solution by boiling off pure water. Find the product flow P in kg/h.
Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 5% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 50 L contains 370 g of CO₂ at 30 °C. Treat it as an ideal gas and find the pressure P.
A fixed amount of Ar goes from 300 kPa, 2 L, 25 °C to 200 kPa and 250 °C. Find the new volume V2.
4 g of Na and 8 g of Cl2 react according to 2Na + Cl2 → 2NaCl. What mass m of NaCl can form?
In the reaction CaCO3 → CaO + CO2, 30 g of CaCO3 reacts completely (the other reactants are in excess) and 12 g of CO2 is collected. Find the percent yield Y.
0.5 mol/L of H₂ and 0.5 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 50. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.05 at the reaction temperature. A container starts with 0.8 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 50 g block of zinc (c = 0.388 J/(g·°C)) at 160 °C is dropped into 100 g of water (c = 4.18 J/(g·°C)) at 25 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find ΔH° for the reaction C3H8 + 5O₂ → 3CO₂ + 4H₂O(l).
A first-order reaction in a batch reactor has k = 0.2 min⁻¹. How long does it take to reach 90% conversion? Find t.
A reaction has a rate constant of 0.005 min⁻¹ at 40 °C and an activation energy of 80 kJ/mol. Find the rate constant k2 at 55 °C.
A liquid-phase first-order reaction A → B (k = 0.1 min⁻¹) runs in a 500 L plug-flow reactor (PFR). The feed enters at 40 L/min with CA0 = 1.5 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.
A first-order liquid-phase reaction (k = 0.15 min⁻¹) runs in two equal CSTRs in series, each of 50 L. The feed rate is 10 L/min, the density is constant and the reactors are at steady state. Find the overall conversion X in percent.
A counter-flow heat exchanger transfers 320 kW. The hot fluid cools from 145 to 35 °C and the cold fluid heats from 10 to 115 °C. The overall heat transfer coefficient is 1500 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow heat exchanger both streams have the same heat capacity rate, ṁ·cp = 3 kW/K. The hot stream enters at 125 °C and the cold stream at 25 °C. The exchanger has A = 5 m² and U = 800 W/(m²·K). Find the hot outlet temperature Th,out.
A wall is made of 100 mm of wood and 50 mm of gypsum board, with an area of 8 m². The outer faces are at 18 °C and -11 °C. Find the heat flow Q̇ through the wall.
A wall of 100 mm concrete and 25 mm wood separates a room at 21 °C from outside air at -2 °C. The convection coefficients are 6 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 4 m². Find the overall heat transfer coefficient U of the wall.
Water (ρ = 1000 kg/m³) flows at 1 m/s through a horizontal pipe, 1000 m long, with an inside diameter of 250 mm. Use the Darcy friction factor f = 0.028 and g = 9.81 m/s². Find the pressure drop Δp over the pipe in kPa.
A pipe 200 m long with an inside diameter of 300 mm (Darcy friction factor f = 0.022) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 3 bends (K = 0.3 each) and a valve (K = 2). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 150 L/s?
A pump delivers 20 L/s of water (ρ = 1000 kg/m³) against a head of 80 m. The pump efficiency is 70% and the electric motor driving it has an efficiency of 94%. Use g = 9.81 m/s². Find the electrical power Pel the motor draws, in kW.
A pump moves 120 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 28 m higher. The pipe is 500 m long with an inside diameter of 250 mm and a Darcy friction factor f = 0.015; the minor-loss coefficients add up to ΣK = 8 (entrance and exit included). Use g = 9.81 m/s². The pump efficiency is 75%. Find the shaft power Pshaft in kW.
Answer: ṁ2 = 190 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: P = 210 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 23.77 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 0.7424 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 423.8 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 5.264 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 10.17 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 90.97 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 0.7795 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.1766 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 30.99 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: ΔH° = −2220 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Negative: the reaction gives off heat (exothermic).
Answer: t = 11.51 min
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: k2 = 0.02037 min⁻¹
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: CA = 0.4298 mol/L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Conversion: X = 71.35%.
Answer: X = 67.35 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 7.779 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Th,out = 67.86 °C
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
The cold outlet sits opposite the hot inlet: Tc,out = Tc,in + (Th,in − Th,out), so ΔT₁ = Th,in − Tc,out = Th,out − Tc,in = ΔT₂.
Heat transferred: Q̇ = 171.4 kW; the cold stream leaves at 82.14 °C.
Answer: Q̇ = 262.9 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: U = 2.39 W/(m²·K)
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Δp = 56 kPa
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The pipe is horizontal and the velocity does not change, so the energy equation reduces to Δp = ρ·g·hf.
Answer: H = 4.376 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: Pel = 23.85 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: Pshaft = 62.12 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical