Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 25% NaOH? Find ṁ2.
An evaporator concentrates a salt solution by boiling off pure water. Find the water evaporated W in kg/h.
Hot light oil cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 15% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 20 L contains 160 g of He at 10 °C. Treat it as an ideal gas and find the pressure P.
A fixed amount of CH₄ goes from 400 kPa, 10 L, 10 °C to 550 kPa and 100 °C. Find the new volume V2.
4 g of CH4 and 64 g of O2 react according to CH4 + 2O2 → CO2 + 2H2O. What mass m of CO2 can form?
In the reaction C3H8 + 5O2 → 3CO2 + 4H2O, 16 g of C3H8 reacts completely (the other reactants are in excess) and 23.8 g of H2O is collected. Find the percent yield Y.
0.5 mol/L of H₂ and 0.5 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 9. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.04 at the reaction temperature. A container starts with 0.1 mol/L of PCl₅ only. Find the equilibrium concentration [Cl2].
A 250 g block of iron (c = 0.449 J/(g·°C)) at 130 °C is dropped into 100 g of water (c = 4.18 J/(g·°C)) at 19 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find ΔH° for the reaction C6H12O6 + 6O₂ → 6CO₂ + 6H₂O(l).
A second-order reaction (−rA = k·CA²) in a batch reactor has k = 1 L/(mol·min) and starts at 1 mol/L. How long does it take to reach 75% conversion? Find t.
A reaction has an activation energy of 60 kJ/mol. At 50 °C it is too slow. To what temperature T2 (in °C) must it be heated to make it 3 times faster?
A liquid-phase first-order reaction A → B (k = 0.5 min⁻¹) runs in a 50 L plug-flow reactor (PFR). The feed enters at 10 L/min with CA0 = 2 mol/L. The density is constant and the reactor is at steady state. Find the outlet concentration CA.
A first-order liquid-phase reaction (k = 0.25 min⁻¹) runs in a 1000 L plug-flow reactor (PFR) fed at 80 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A counter-flow heat exchanger transfers 500 kW. The hot fluid cools from 160 to 110 °C and the cold fluid heats from 30 to 140 °C. The overall heat transfer coefficient is 800 W/(m²·K). Find the heat transfer area A needed.
Steam condenses at a constant 110 °C on the outside of the tubes of a condenser with a heat transfer area of 3 m² and U = 1500 W/(m²·K). Cooling water (0.5 kg/s, cp = 4.18 kJ/(kg·K)) enters the tubes at 30 °C. Find the water outlet temperature Tc,out.
A wall is made of 100 mm of expanded polystyrene and 50 mm of glass, with an area of 20 m². The outer faces are at 17 °C and 6 °C. Find the heat flow Q̇ through the wall.
A wall of 150 mm glass and 50 mm wood separates a room at 20 °C from outside air at -9 °C. The convection coefficients are 7.7 W/(m²·K) inside and 30 W/(m²·K) outside, and the wall area is 10 m². Find the overall heat transfer coefficient U of the wall.
Water flows at 5 L/s through a pipe 400 m long with an inside diameter of 75 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the friction head loss hf.
A pipe 100 m long with an inside diameter of 300 mm (Darcy friction factor f = 0.022) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 4 bends (K = 0.3 each) and a valve (K = 10). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 100 L/s?
A pump delivers 10 L/s of water (ρ = 1000 kg/m³) against a head of 24 m. The pump efficiency is 60% and the electric motor driving it has an efficiency of 90%. Use g = 9.81 m/s². Find the electrical power Pel the motor draws, in kW.
A pump moves 75 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 23 m higher. The pipe is 100 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.018; the minor-loss coefficients add up to ΣK = 6 (entrance and exit included). Use g = 9.81 m/s². The pump efficiency is 65%. Find the shaft power Pshaft in kW.
Answer: ṁ2 = 300 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: W = 3010 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 35.12 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 1.537 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 4705 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 9.584 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 10.98 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 91.01 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 0.6 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [Cl2] = 0.04633 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 42.5 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: ΔH° = −2802 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Negative: the reaction gives off heat (exothermic).
Answer: t = 3 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: T2 = 66.72 °C
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: CA = 0.1642 mol/L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Conversion: X = 91.79%.
Answer: X = 95.61 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 14.44 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Tc,out = 100.7 °C
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
With ΔT₁ = Ts − Tc,in and ΔT₂ = Ts − Tc,out, the difference ΔT₁ − ΔT₂ equals the water temperature rise, so the rise cancels.
Heat transferred: Q̇ = 147.8 kW.
Answer: Q̇ = 75.62 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: U = 1.63 W/(m²·K)
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 6.267 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: H = 2.044 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: Pel = 4.36 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: Pshaft = 30.97 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical