Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 20% salt? Find ṁ2.
An evaporator concentrates a salt solution by boiling off pure water. Find the product flow P in kg/h.
Hot glycol mix cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot light oil heats water in an exchanger that loses 10% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
A tank of 50 L contains 430 g of CO₂ at 45 °C. Treat it as an ideal gas and find the pressure P.
Find the density ρ of O₂ at 650 kPa and 160 °C, treating it as an ideal gas.
8 g of Fe2O3 and 80 g of CO react according to Fe2O3 + 3CO → 2Fe + 3CO2. What mass m of Fe can form?
In the reaction C3H8 + 5O2 → 3CO2 + 4H2O, 4 g of C3H8 reacts completely (the other reactants are in excess) and 5.56 g of H2O is collected. Find the percent yield Y.
0.4 mol/L of H₂ and 0.4 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 25. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.2 at the reaction temperature. A container starts with 0.1 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 50 g block of copper (c = 0.385 J/(g·°C)) at 100 °C is dropped into 200 g of water (c = 4.18 J/(g·°C)) at 15 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find the heat q released when 50 g of C4H10 (M = 58.12 g/mol) burns completely: 2C4H10 + 13O₂ → 8CO₂ + 10H₂O(l). Give q as a positive number.
A second-order reaction (−rA = k·CA²) has k = 0.1 L/(mol·min) and an initial concentration of 0.5 mol/L. Find its first half-life t½.
A first-order reaction has a rate constant of 0.02 s⁻¹ at 40 °C and an activation energy of 75 kJ/mol. Find the pre-exponential factor A in the Arrhenius equation.
A first-order liquid-phase reaction must reach 50% conversion. How many times larger must a CSTR be than a PFR for the same feed rate, rate constant and conversion? Find the ratio VCSTR/VPFR.
A first-order liquid-phase reaction (k = 0.5 min⁻¹) runs in an 800 L CSTR fed at 100 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A counter-flow heat exchanger transfers 320 kW. The hot fluid cools from 170 to 35 °C and the cold fluid heats from 15 to 55 °C. The overall heat transfer coefficient is 1500 W/(m²·K). Find the heat transfer area A needed.
Hot oil (2 kg/s, cp = 2.5 kJ/(kg·K)) cools from 100 to 40 °C in a counter-flow exchanger. It heats 2 kg/s of water (cp = 4.18 kJ/(kg·K)) that enters at 20 °C. With U = 1500 W/(m²·K), find the heat transfer area A needed.
A wall is made of 100 mm of mineral wool and 75 mm of expanded polystyrene, with an area of 15 m². The outer faces are at 22 °C and -5 °C. Find the heat flow Q̇ through the wall.
A wall of 150 mm expanded polystyrene and 150 mm glass separates a room at 21 °C from outside air at -9 °C. The convection coefficients are 8 W/(m²·K) inside and 20 W/(m²·K) outside, and the wall area is 6 m². Find the temperature Ts of the inside surface of the wall.
Water flows at 40 L/s through a pipe 100 m long with an inside diameter of 200 mm. Use the Darcy friction factor f = 0.015 and g = 9.81 m/s². Find the friction head loss hf.
Two open reservoirs are joined by a pipe 150 m long with an inside diameter of 150 mm and a Darcy friction factor f = 0.022. The water surface of the upper reservoir is 26 m above that of the lower one. The minor losses are a square-edged entrance (K = 0.5), 2 bends (K = 0.3 each), a valve (K = 10) and the exit into the lower reservoir (K = 1.0). Use g = 9.81 m/s². Find the flow rate Q in L/s.
A pump with an efficiency of 80% delivers 150 L/s of water (ρ = 1000 kg/m³) against a head of 32 m. Use g = 9.81 m/s². Find the shaft power Pshaft needed, in kW.
A pump moves 120 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 7 m higher. The pipe is 100 m long with an inside diameter of 250 mm and a Darcy friction factor f = 0.022; the minor-loss coefficients add up to ΣK = 5 (entrance and exit included). Use g = 9.81 m/s². The upper tank is closed and the air above its water is at a gauge pressure of 100 kPa. Find the head H the pump must add.
Answer: ṁ2 = 675 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: P = 1357 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 55.14 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 1.55 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: P = 516.9 kPa
Ideal gas law: PV = nRT, with n = m/M.
Answer: ρ = 5.776 kg/m³
Ideal gas density: ρ = PM/(RT).
Answer: m = 5.596 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 85.04 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 0.5714 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.02679 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 16.91 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: q = 2475 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: t½ = 20 min
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Each later half-life is twice as long, because C₀ has halved.
Answer: A = 6.483 × 10¹⁰ s⁻¹
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: VCSTR/VPFR = 1.443
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
The gap grows quickly at high conversion.
Answer: X = 80 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 3.928 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: A = 6.561 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 87.23 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Ts = 20.19 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 0.6197 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: Q = 68.35 L/s
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Both surfaces are open to the air and practically at rest, so all of Δz is lost in the pipe.
Answer: Pshaft = 58.86 kW
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 21.4 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are practically at rest, so there is no velocity head term.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical