Mass balance
- Steady state
- in = out
- Total balance
- ṁ1 + ṁ2 = ṁ3
- Component balance
- ṁ1x1 + ṁ2x2 = ṁ3x3
- Evaporator
- F·xF = P·xP, W = F − P
Formula sheets, the key method steps for every topic and 24 practice problems, with full solutions at the back.
How much of stream 2 must be added each hour to stream 1 so that the blended product contains 20% sugar? Find ṁ2.
An evaporator concentrates a NaOH solution by boiling off pure water. Find the product flow P in kg/h.
Hot glycol mix cools water in a counter-flow heat exchanger with no heat loss. Find the water outlet temperature tout.
Hot glycol mix heats water in an exchanger that loses 10% of the heat released by the hot stream to the surroundings. Find the water flow rate ṁc needed.
What volume V does 200 g of Ar occupy at 550 kPa and 25 °C? Treat it as an ideal gas.
A fixed amount of Ar goes from 300 kPa, 5 L, 10 °C to 800 kPa and 70 °C. Find the new volume V2.
30 g of Al and 24 g of Cl2 react according to 2Al + 3Cl2 → 2AlCl3. What mass m of AlCl3 can form?
In the reaction Fe2O3 + 3CO → 2Fe + 3CO2, 20 g of Fe2O3 reacts completely (the other reactants are in excess) and 10.25 g of CO2 is collected. Find the percent yield Y.
1 mol/L of H₂ and 1 mol/L of I₂ are put in a container and react: H₂ + I₂ ⇌ 2HI, with Kc = 64. Find the equilibrium concentration [HI].
PCl₅ decomposes: PCl₅ ⇌ PCl₃ + Cl₂, with Kc = 0.01 at the reaction temperature. A container starts with 0.25 mol/L of PCl₅ only. Find the equilibrium concentration [PCl5].
A 75 g block of zinc (c = 0.388 J/(g·°C)) at 90 °C is dropped into 400 g of water (c = 4.18 J/(g·°C)) at 15 °C in an insulated cup. Find the final temperature Tf.
Use the standard enthalpies of formation to find ΔH° for the reaction C3H8 + 5O₂ → 3CO₂ + 4H₂O(l).
In a first-order reaction the concentration of A falls from 1.2 mol/L to 0.96 mol/L in 60 min. Find the rate constant k.
A first-order reaction has a rate constant of 0.005 s⁻¹ at 80 °C and an activation energy of 40 kJ/mol. Find the pre-exponential factor A in the Arrhenius equation.
A first-order liquid-phase reaction A → B with k = 0.1 min⁻¹ is carried out in a plug-flow reactor (PFR) fed at 100 L/min. The density is constant and the reactor is at steady state. Find the reactor volume V in litres for 50% conversion of A.
A first-order liquid-phase reaction (k = 0.1 min⁻¹) runs in a 1500 L CSTR fed at 80 L/min. The density is constant and the reactor is at steady state. Find the conversion X in percent.
A parallel-flow heat exchanger transfers 340 kW. The hot fluid cools from 170 to 130 °C and the cold fluid heats from 25 to 115 °C. The overall heat transfer coefficient is 800 W/(m²·K). Find the heat transfer area A needed.
In a counter-flow double-pipe heat exchanger, hot oil (0.2 kg/s, cp = 2.5 kJ/(kg·K)) flows in the inner tube and cools from 100 to 60 °C. Water (0.5 kg/s, cp = 4.18 kJ/(kg·K)) in the annulus enters at 25 °C. The inner tube has a diameter of 25 mm, and U = 200 W/(m²·K) is based on this diameter. Find the tube length L needed.
A wall is made of 100 mm of mineral wool and 100 mm of gypsum board, with an area of 6 m². The outer faces are at 15 °C and -6 °C. Find the heat flow Q̇ through the wall.
A wall of 100 mm brick and 50 mm concrete separates a room at 21 °C from outside air at -14 °C. The convection coefficients are 7.7 W/(m²·K) inside and 20 W/(m²·K) outside, and the wall area is 10 m². Find the temperature Ts of the inside surface of the wall.
Water flows at a mean velocity of 2.4 m/s through a pipe 1000 m long with an inside diameter of 75 mm. Use the Darcy friction factor f = 0.018 and g = 9.81 m/s². Find the friction head loss hf.
A pipe 400 m long with an inside diameter of 250 mm (Darcy friction factor f = 0.018) runs from an open reservoir and discharges as a free jet into the air. The minor losses are a square-edged entrance (K = 0.5), 3 bends (K = 0.3 each) and a valve (K = 10). Use g = 9.81 m/s². How far H must the reservoir surface be above the pipe outlet for a flow rate of 120 L/s?
In a test, a pump delivers 10 L/s of water (ρ = 1000 kg/m³) against a head of 50 m while its shaft takes 7.5 kW. Use g = 9.81 m/s². Find the pump efficiency η in percent.
A pump moves 75 L/s of water (ρ = 1000 kg/m³) from an open lower reservoir to an upper tank whose water surface is 7 m higher. The pipe is 300 m long with an inside diameter of 200 mm and a Darcy friction factor f = 0.02; the minor-loss coefficients add up to ΣK = 3 (entrance and exit included). Use g = 9.81 m/s². The upper tank is closed and the air above its water is at a gauge pressure of 350 kPa. Find the head H the pump must add.
Answer: ṁ2 = 900 kg/h
Steady-state mass balance: in = out for the total and for each component. Blending problems combine both.
Answer: P = 369.2 kg/h
Tie component: a component that passes through unchanged in one stream (here the solute) links the flows directly. Then the total balance gives the rest.
Answer: tout = 65.93 °C
Exchanger energy balance: with no losses, ṁhcp,h(Th,in − Th,out) = ṁccp,c(tout − tin).
Answer: ṁc = 0.4651 kg/s
Energy balance with losses: heat released = heat absorbed + heat lost.
Answer: V = 22.56 L
Ideal gas law: PV = nRT, with n = m/M.
Answer: V2 = 2.272 L
Combined gas law: for a fixed amount of ideal gas, P1V1/T1 = P2V2/T2.
Answer: m = 30.09 g
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: Y = 61.99 %
Stoichiometry: a balanced equation counts particles, not grams. Convert mass to moles with n = m/M, use the coefficients of the equation as the mole ratio, then convert back with m = n·M. With two reactants, the limiting reactant is the one that runs out first and fixes how much product forms.
Answer: [HI] = 1.6 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: [PCl5] = 0.2048 mol/L
Chemical equilibrium: for aA + bB ⇌ cC + dD, the equilibrium constant is Kc = [C]c[D]d/([A]a[B]b), using concentrations at equilibrium. An ICE table (Initial, Change, Equilibrium) links the starting amounts to the equilibrium amounts through one unknown x, scaled by the coefficients.
Answer: Tf = 16.28 °C
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Answer: ΔH° = −2220 kJ
Heat and enthalpy: heating a substance takes q = m·c·ΔT. In a calorimeter the heat lost by the hot object equals the heat gained by the cold one. The enthalpy change of a reaction follows from enthalpies of formation: ΔH° = ΣΔH°f(products) − ΣΔH°f(reactants), each multiplied by its coefficient.
Negative: the reaction gives off heat (exothermic).
Answer: k = 0.003719 min⁻¹
Integrated rate laws: zero order: C = C₀ − kt (straight line, t½ = C₀/(2k)); first order: ln(C₀/C) = kt (t½ = ln 2/k); second order: 1/C − 1/C₀ = kt (t½ = 1/(kC₀)). Conversion X means C = C₀(1 − X).
Answer: A = 4127 s⁻¹
Reaction rates: for a first-order reaction −dC/dt = kC, so C = C₀·e−kt and the half-life ln 2/k does not depend on concentration. For a second-order reaction 1/C = 1/C₀ + kt. The rate constant rises with temperature following Arrhenius: k = A·e−Ea/(RT).
Answer: V = 693.1 L
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: X = 65.22 %
Ideal reactors, first-order reaction (−rA = k·CA) at steady state, with space time τ = V/Q. A CSTR is perfectly mixed, so the whole volume reacts at the low outlet concentration: τ = X/(k·(1 − X)) and CA = CA0/(1 + k·τ). In a PFR each slice of fluid reacts like a small batch reactor: τ = ln(1/(1 − X))/k and CA = CA0·e−k·τ. For the same conversion a CSTR always needs more volume than a PFR.
Answer: A = 7.417 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In parallel flow both inlets are at the same end, and both outlets at the other.
Answer: L = 26.18 m
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Q̇ = 40.8 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: Ts = 8.177 °C
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: hf = 70.46 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
Answer: H = 12.55 m
Pipe flow: the Reynolds number Re = V·D/ν = ρ·V·D/μ tells laminar flow (Re below about 2000) from turbulent flow (above about 4000). Friction along a pipe costs the Darcy–Weisbach head loss hf = f·(L/D)·V²/(2g). Fittings, valves, the entrance and the exit add minor losses hm = ΣK·V²/(2g). Between two open reservoir surfaces the energy equation gives Δz = hf + hm, with the exit loss K = 1 included.
The outlet jet still carries its velocity head; it is not a loss but it has to be supplied.
Answer: η = 65.4 %
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Answer: H = 52.26 m
Pump power: the power given to the water is the hydraulic power Ph = ρ·g·Q·H = Q·Δp. The shaft must deliver more because the pump loses some: Pshaft = Ph/ηpump, and the motor draws Pel = Pshaft/ηmotor. The pump head H follows from the energy equation: static lift + pressure head + all friction and minor losses.
Both surfaces are practically at rest, so there is no velocity head term.
This is independent practice material. ExamProblems is not affiliated with or endorsed by the organisation that runs this exam, and the exam name is used only to describe the content. The FE exam is run by NCEES, which is not affiliated with ExamProblems and does not endorse it.
ExamProblems · examproblems.com/courses/fe-exam-chemical