Heat conduction
- Fourier’s law
- Q̇ = kAΔT/L
- Conduction resistance
- R = L/(kA)
- Convection resistance
- R = 1/(hA)
- Resistances in series
- Q̇ = ΔTtotal/ΣR
- U-value
- U = 1/(ΣR·A)
Formula sheets, the key method steps for every topic and 4 practice problems, with full solutions at the back.
A wall is made of 150 mm of brick and 25 mm of gypsum board, with an area of 8 m². The outer faces are at 19 °C and -6 °C. Find the heat flow Q̇ through the wall.
A wall of 50 mm glass and 150 mm mineral wool separates a room at 21 °C from outside air at -4 °C. The convection coefficients are 6 W/(m²·K) inside and 25 W/(m²·K) outside, and the wall area is 10 m². Find the overall heat transfer coefficient U of the wall.
A shell-and-tube heat exchanger (one shell pass, two tube passes) must transfer 160 kW. The hot fluid cools from 125 to 50 °C and the cold fluid heats from 30 to 90 °C. The LMTD correction factor for this arrangement is F = 0.8, and U = 500 W/(m²·K). Find the heat transfer area A needed.
Steam condenses at a constant 100 °C on the outside of the tubes of a condenser with a heat transfer area of 1.5 m² and U = 1000 W/(m²·K). Cooling water (1 kg/s, cp = 4.18 kJ/(kg·K)) enters the tubes at 25 °C. Find the water outlet temperature Tc,out.
Answer: Q̇ = 562.8 W
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: U = 0.2495 W/(m²·K)
Thermal resistance: steady heat flow through layers in series behaves like current through resistors in series: Q̇ = ΔT/ΣR, with R = L/(kA) for a conducting layer and R = 1/(hA) for a convecting surface. The temperature drop across each layer is proportional to its resistance.
Answer: A = 14.92 m²
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
In counter-flow the hot inlet faces the cold outlet, and the hot outlet faces the cold inlet.
Answer: Tc,out = 47.61 °C
LMTD method: the temperature difference between the streams changes along the exchanger, so the rate equation uses its logarithmic mean: Q̇ = U·A·ΔTlm, with ΔTlm = (ΔT₁ − ΔT₂)/ln(ΔT₁/ΔT₂), where ΔT₁ and ΔT₂ are the differences at the two ends. Counter-flow gives a larger ΔTlm than parallel flow for the same inlet and outlet temperatures.
With ΔT₁ = Ts − Tc,in and ΔT₂ = Ts − Tc,out, the difference ΔT₁ − ΔT₂ equals the water temperature rise, so the rise cancels.
Heat transferred: Q̇ = 94.53 kW.
ExamProblems · examproblems.com/courses/heat-transfer