1Formulas and methods
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
Gears & gear trains
Meshing gears
n1·N1 = n2·N2
Torque
T2 = T1·(N2/N1)·η
Power
P = T·ω, ω = 2π·n/60
Compound train
total ratio = product of the stage ratios
Data acquisition & sampling
Nyquist criterion
fs > 2·fmax, fN = fs/2
Alias frequency
fa = |f − k·fs|, k = round(f/fs)
Step size
1 LSB = VFSR/2ᴺ
Quantisation error (rounding)
±½ LSB
Truncating ADC code
D = ⌊Vin/LSB⌋
Bits for a resolution r
2ᴺ ≥ span/r
Ideal SQNR, full-scale sine
SQNR = 6.02·N + 1.76 dB
Data rate
channels × fs × N bit/s
Multiplexed ADC
fs = 1/(n·(tc + tset))
UART
Tb = 1/baud; 8N1 = 10 bits per byte; bytes/s = baud/bits per frame
Baud rate divider
baud = fclk/(16·D)
Method
Write down what is given: sampling rate, signal frequencies, number of bits, input range, baud rate.
For sampling questions, compare each frequency with fs/2; a higher frequency appears at fa = |f − k·fs| with the nearest multiple of fs.
For resolution questions, find 1 LSB = VFSR/2ᴺ, or the smallest N with 2ᴺ ≥ span/resolution.
For data rates and UART links, count everything that is sent: channels, samples per second, bits or whole bytes per sample, and the start, parity and stop bits of every frame.
Wheatstone bridge & strain gauges
Divider voltages
Va = VsR2/(R1 + R2), Vb = VsR4/(R3 + R4)
Output
Vab = Va − Vb
Balance
R1/R2 = R3/R4
Slide-wire bridge
R/Rx = l/(100 − l)
Thévenin resistance
Rth = R1∥R2 + R3∥R4
Gauge factor
ΔR/R = GF·ε
Bridge output
quarter Vs·GF·ε/4, half Vs·GF·ε/2, full Vs·GF·ε
Small change, one arm
Vab ≈ Vs·ΔR/(4R)
Stress
σ = E·ε
Method
Treat the bridge as two voltage dividers across the same supply.
For balance, set R₁/R₂ = R₃/R₄ and solve for the unknown resistor.
For an unbalanced bridge, find Va and Vb from the dividers and subtract; use the Thévenin equivalent when a meter loads the output.
For strain gauges, convert strain to ΔR/R = GF·ε and use Vs·GF·ε/4, /2 or ×1 for a quarter, half or full bridge.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.DC motorsMedium
A DC motor (k = 1 V·s/rad, Ra = 2 Ω) runs from 120 V. At full load it draws 5 A. Neglecting the no-load current, find its speed regulation SR = (n₀ − nFL)/nFL in percent.
V = 120 Vk = 1 V·s/radRa = 2 ΩIFL = 5 A
SR = %
2.DC motorsHard
A 240 V DC motor has an armature resistance of 0.4 Ω. Find the series starting resistance Rst that limits the starting current to 30 A.
V = 240 VRa = 0.4 ΩImax = 30 A
Rst = Ω
3.Gears & gear trainsMedium
A 1.5 kW motor running at 1440 rpm drives a pinion with 20 teeth and a module of 2 mm. Find the tangential force Ft on the pinion teeth.
P = 1.5 kWn = 1440 rpmN1 = 20m = 2 mm
Ft = N
4.Gears & gear trainsHard
A 7.5 kW motor at 2900 rpm drives gear A (40 teeth), which meshes with gear B (80 teeth). Gear C (24 teeth) on the same shaft as B drives gear D (32 teeth) on the output shaft. Each gear mesh has an efficiency of 95%. Find the output torque Tout.
Find the ideal signal-to-quantisation-noise ratio SQNR of a 10-bit ADC for a full-scale sine wave.
N = 10
SQNR = dB
6.Data acquisition & samplingHard
A 16-bit ADC streams every sample over a UART at 38400 baud, format 8E1 (start bit, 8 data bits, even parity, 1 stop bit). Each sample is sent as 2 whole byte(s) and the link is busy all the time. Find the highest signal frequency fmax that can be sampled without aliasing, in Hz.
baud = 38400 BdN = 168E1
fmax = Hz
7.Wheatstone bridge & strain gaugesMedium
A bridge has four 100 Ω arms and Vs = 10 V. The sensor R₂ increases by ΔR = 5 Ω. Find the exact output Vab in mV.
Vs = 10 VR = 100 ΩΔR = 5 Ω
Vab = mV
8.Wheatstone bridge & strain gaugesHard
A quarter bridge (one active gauge, GF = 2) is excited with 5 V. The largest strain to be measured is 600 µε, and it must give 3.3 V at the input of an analogue-to-digital converter. Find the amplifier gain G.
Vs = 5 VGF = 2εmax = 600 µεVFS = 3.3 V
G =
9.Steady-state error & PID controlMedium
A unity-feedback loop has G(s) = K/((s + 1)(s + 4)). Find the gain K that gives a steady-state error of 2 % for a step input.
G(s) = K/((s + 1)(s + 4))ess = 2 %
K =
10.Steady-state error & PID controlHard
A proportional controller K = 25 drives the plant G(s) = 10/(s(s + 8)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 10/(s(s + 8))K = 25
%OS = %
11.Step responseMedium
A system has the transfer function G(s) = 28/(s² + 5s + 28) and receives a unit step input. The poles are s = σ ± jωd. Find the real part σ.
G(s) = 28/(s² + 5s + 28)
σ =
12.Step responseHard
A second-order system without zeros must have a step response with 25 % overshoot. Find the damping ratio ζ.
%OS = 25 %
ζ =
3Solutions
1.DC motors
Answer: SR = 9.091 %
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load and full-load speed
n₀ = 60·120/(2π·1) = 1146 rpm
nFL = 60·(120 − 5·2)/(2π·1) = 1050 rpm
Speed regulation
SR = (1146 − 1050)/1050·100 = 9.091 %
Answer
SR = 9.091 %
2.DC motors
Answer: Rst = 7.6 Ω
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Total resistance
Ra + Rst = 240/30 = 8 Ω
Starting resistor
Rst = 8 − 0.4 = 7.6 Ω
Answer
Rst = 7.6 Ω
The resistor is cut out step by step as the motor speeds up and the back-EMF grows.
3.Gears & gear trains
Answer: Ft = 497.4 N
Gear geometry: the module m sets the tooth size. A gear with N teeth has a pitch diameter d = m·N, two meshing gears have the same module, and their centre distance is a = (d₁ + d₂)/2 = m·(N₁ + N₂)/2. The pitch-line speed is v = π·d·n/60, and the tangential tooth force follows from the torque: Ft = 2T/d.
Torque on the pinion
ω = 2π·1440/60 = 150.8 rad/s
T = P/ω = 1500/150.8 = 9.947 N·m
Pitch diameter
d = m·N = 2·20 = 40 mm
Tangential force
Ft = 2T/d = 2·9.947/0.04 = 497.4 N
Answer
Ft = 497.4 N
4.Gears & gear trains
Answer: Tout = 59.44 N·m
Gear trains: meshing gears have the same speed at the teeth, so n₁·N₁ = n₂·N₂: the gear with fewer teeth turns faster. Gears on one shaft turn at the same speed. Power is passed on (minus losses), so torque goes up when speed goes down: T₂ = T₁·(N₂/N₁)·η, and P = T·ω with ω = 2π·n/60.
Output speed
nout = 2900·(40/80)·(24/32) = 1088 rpm
ωout = 2π·1088/60 = 113.9 rad/s
Output power and torque
Pout = 7500·0.95² = 6769 W
Tout = Pout/ωout = 6769/113.9 = 59.44 N·m
Answer
Tout = 59.44 N·m
5.Data acquisition & sampling
Answer: SQNR = 61.96 dB
ADC resolution: an N-bit converter divides its full-scale range VFSR into 2ᴺ codes, from 0 to 2ᴺ − 1. One step is 1 LSB = VFSR/2ᴺ: the smallest change the converter can show. A truncating ADC gives the code ⌊Vin/LSB⌋; a rounding ADC is never more than ½ LSB away from the true value, its quantisation error. Every extra bit halves the LSB and adds about 6 dB to the ideal signal-to-quantisation-noise ratio SQNR = 6.02·N + 1.76 dB for a full-scale sine. To reach a resolution r over a span, choose the smallest N with 2ᴺ ≥ span/r.
Ideal SQNR
SQNR = 6.02·10 + 1.76 = 61.96 dB
Answer
SQNR = 61.96 dB
6.Data acquisition & sampling
Answer: fmax = 872.7 Hz
UART: an asynchronous serial link sends each byte as a frame: one start bit (low), the data bits, an optional parity bit and one or two stop bits (high). The baud rate is the number of bits per second, so one bit lasts Tb = 1/baud and a frame of n bits lasts n/baud. The common 8N1 format has 10 bits per byte. The baud generator divides the clock: baud = fclk/(16·D) with a whole number D, so the real baud rate differs slightly from the target; an error below about 2 % is usually acceptable.
Bits per sample on the line
2·11 = 22 bit
Highest sampling rate
fs,max = 38400/22 = 1745 Hz
Nyquist limit
fmax = 1745/2 = 872.7 Hz
Answer
fmax = 872.7 Hz
7.Wheatstone bridge & strain gauges
Answer: Vab = 122 mV
Wheatstone bridge: two voltage dividers share one supply Vs. The left divider R1–R2 gives Va = Vs·R2/(R1 + R2) and the right divider R3–R4 gives Vb = Vs·R4/(R3 + R4); the output is Vab = Va − Vb. The bridge is balanced (Vab = 0, no current in the meter) when R1/R2 = R3/R4, that is R1·R4 = R2·R3. Seen from the output, the bridge is a Thévenin source with Rth = R1∥R2 + R3∥R4.
Node voltages
Va = 10·105/205 = 5.122 V
Vb = 5 V
Output
Vab = 122 mV
Answer
Vab = 122 mV
The linear estimate Vs·ΔR/(4R) = 125 mV is 2.5 % too high: a quarter bridge is not quite linear.
8.Wheatstone bridge & strain gauges
Answer: G = 2200
Strain gauges: a gauge changes its resistance with strain: ΔR/R = GF·ε, where the gauge factor GF is about 2 for metal foil. In a bridge with all arms equal to R, one active gauge (quarter bridge) gives Vo ≈ Vs·GF·ε/4. Two active gauges with opposite strains in adjacent arms (half bridge) give Vs·GF·ε/2, and four (full bridge) give Vs·GF·ε. Stress follows from Hooke’s law, σ = E·ε. Load cells state their sensitivity in mV/V: the output at full load per volt of excitation.
Bridge output at full scale
Vo = 1.5 mV
Gain
G = 3.3/0.0015 = 2200
Answer
G = 2200
9.Steady-state error & PID control
Answer: K = 196
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Required error constant
1/(1 + Kp) = 0.02 → Kp = 49
Gain
K/4 = 49 → K = 196
Answer
K = 196
Check the closed-loop stability as well: for this second-order loop any K > 0 is stable.
10.Steady-state error & PID control
Answer: %OS = 43.98 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 8) + 25·10 = s² + 8s + 250
ωₙ and ζ
ωₙ = √250 = 15.81 rad/s
ζ = 8/(2·15.81) = 0.253
Overshoot
%OS = 100·e−0.253π/√(1 − 0.253²) = 43.98 %
Answer
%OS = 43.98 %
11.Step response
Answer: σ = −2.5
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 28 → ωₙ = 5.292 rad/s
2ζωₙ = 5 → ζ = 5/(2·5.292) = 0.4725
Result
σ = −ζωₙ = −5/2 = −2.5
Answer
σ = −2.5
12.Step response
Answer: ζ = 0.4037
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).