In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
Gears & gear trains
Meshing gears
n1·N1 = n2·N2
Torque
T2 = T1·(N2/N1)·η
Power
P = T·ω, ω = 2π·n/60
Compound train
total ratio = product of the stage ratios
Data acquisition & sampling
Nyquist criterion
fs > 2·fmax, fN = fs/2
Alias frequency
fa = |f − k·fs|, k = round(f/fs)
Step size
1 LSB = VFSR/2ᴺ
Quantisation error (rounding)
±½ LSB
Truncating ADC code
D = ⌊Vin/LSB⌋
Bits for a resolution r
2ᴺ ≥ span/r
Ideal SQNR, full-scale sine
SQNR = 6.02·N + 1.76 dB
Data rate
channels × fs × N bit/s
Multiplexed ADC
fs = 1/(n·(tc + tset))
UART
Tb = 1/baud; 8N1 = 10 bits per byte; bytes/s = baud/bits per frame
Baud rate divider
baud = fclk/(16·D)
Method
Write down what is given: sampling rate, signal frequencies, number of bits, input range, baud rate.
For sampling questions, compare each frequency with fs/2; a higher frequency appears at fa = |f − k·fs| with the nearest multiple of fs.
For resolution questions, find 1 LSB = VFSR/2ᴺ, or the smallest N with 2ᴺ ≥ span/resolution.
For data rates and UART links, count everything that is sent: channels, samples per second, bits or whole bytes per sample, and the start, parity and stop bits of every frame.
Wheatstone bridge & strain gauges
Divider voltages
Va = VsR2/(R1 + R2), Vb = VsR4/(R3 + R4)
Output
Vab = Va − Vb
Balance
R1/R2 = R3/R4
Slide-wire bridge
R/Rx = l/(100 − l)
Thévenin resistance
Rth = R1∥R2 + R3∥R4
Gauge factor
ΔR/R = GF·ε
Bridge output
quarter Vs·GF·ε/4, half Vs·GF·ε/2, full Vs·GF·ε
Small change, one arm
Vab ≈ Vs·ΔR/(4R)
Stress
σ = E·ε
Method
Treat the bridge as two voltage dividers across the same supply.
For balance, set R₁/R₂ = R₃/R₄ and solve for the unknown resistor.
For an unbalanced bridge, find Va and Vb from the dividers and subtract; use the Thévenin equivalent when a meter loads the output.
For strain gauges, convert strain to ΔR/R = GF·ε and use Vs·GF·ε/4, /2 or ×1 for a quarter, half or full bridge.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.DC motorsMedium
A DC motor with k = 1.5 V·s/rad runs from 110 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.
V = 110 Vk = 1.5 V·s/rad
n0 = rpm
2.DC motorsHard
A small DC motor has an armature resistance of 1.5 Ω and runs from 110 V. Neglecting rotational losses, find the largest mechanical power Pmax it can develop at any speed.
V = 110 VRa = 1.5 Ω
Pmax = W
3.Gears & gear trainsMedium
An 11 kW motor running at 2900 rpm drives a pinion with 25 teeth, which meshes with a gear with 32 teeth. The gear pair has an efficiency of 98%. Find the output torque T2 on the gear shaft.
P = 11 kWn1 = 2900 rpmN1 = 25N2 = 32η = 98%
T2 = N·m
4.Gears & gear trainsHard
An 11 kW motor at 2900 rpm drives gear A (18 teeth), which meshes with gear B (20 teeth). Gear C (12 teeth) on the same shaft as B drives gear D (18 teeth) on the output shaft. Each gear mesh has an efficiency of 97%. Find the output torque Tout.
An ADC with an input range of 0 to 1 V must resolve steps of 1 mV or smaller. Find the smallest number of bits N.
VFSR = 1 Vresolution = 1 mV
N =
6.Data acquisition & samplingHard
A 900 Hz square wave is sampled at 2 kHz with no anti-aliasing filter. A square wave contains the odd harmonics 3f₁, 5f₁, 7f₁, … At which frequency fa does its harmonic 3f₁ appear in the sampled data? Give it in Hz.
f₁ = 900 Hzfs = 2 kHzharmonic: 3f₁
fa = Hz
7.Wheatstone bridge & strain gaugesMedium
A bridge with four 500 Ω arms is supplied with 2 V. When the sensor R₂ changes, the output reads Vab = 9.9 mV. Find the exact change ΔR of R₂.
Vs = 2 VR = 500 ΩVab = 9.9 mV
ΔR = Ω
8.Wheatstone bridge & strain gaugesHard
A 1000 Ω strain gauge with gauge factor 2.1 is bonded to a steel bar. Under load its resistance rises by 1.575 Ω. Find the strain ε in microstrain (µε).
R = 1000 ΩGF = 2.1ΔR = 1.575 Ω
ε = µε
9.Steady-state error & PID controlMedium
A process G(s) = 1/(2s + 1) is controlled by a proportional gain K = 10 in a unity-feedback loop. Find the steady-state error ess for a step, as a percentage of the step size.
G(s) = 1/(2s + 1)K = 10
ess = %
10.Steady-state error & PID controlHard
A proportional controller K = 50 drives the plant G(s) = 5/(s(s + 10)) in a unity-feedback loop. Find the peak time tp of the step response.
G(s) = 5/(s(s + 10))K = 50
tp = s
11.Step responseMedium
A system has the transfer function G(s) = 26/(s² + 8s + 52) and receives a unit step input. Find the natural frequency ωn in rad/s.
G(s) = 26/(s² + 8s + 52)
ωn = rad/s
12.Step responseHard
A unity negative feedback loop has G(s) = K/(s(s + 5)). Find the gain K that gives a step response with 15 % overshoot.
G(s) = K/(s(s + 5))%OS = 15 %
K =
3Solutions
1.DC motors
Answer: n0 = 700.3 rpm
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load speed
ω₀ = V/k = 110/1.5 = 73.33 rad/s
n0 = 60·73.33/(2π) = 700.3 rpm
Answer
n0 = 700.3 rpm
2.DC motors
Answer: Pmax = 2017 W
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Power as a function of the back-EMF
P(E) = E·(V − E)/Ra
dP/dE = 0 → E = V/2 = 55 V
Maximum power
Pmax = (V/2)²/Ra = V²/(4Ra) = 110²/(4·1.5) = 2017 W
Answer
Pmax = 2017 W
At this point the efficiency is only 50 %, so real motors run well above half speed.
3.Gears & gear trains
Answer: T2 = 45.44 N·m
Gear trains: meshing gears have the same speed at the teeth, so n₁·N₁ = n₂·N₂: the gear with fewer teeth turns faster. Gears on one shaft turn at the same speed. Power is passed on (minus losses), so torque goes up when speed goes down: T₂ = T₁·(N₂/N₁)·η, and P = T·ω with ω = 2π·n/60.
Motor torque
ω₁ = 2π·2900/60 = 303.7 rad/s
T1 = P/ω₁ = 11000/303.7 = 36.22 N·m
Output torque
T2 = 36.22·32/25·0.98 = 45.44 N·m
Answer
T2 = 45.44 N·m
4.Gears & gear trains
Answer: Tout = 56.8 N·m
Gear trains: meshing gears have the same speed at the teeth, so n₁·N₁ = n₂·N₂: the gear with fewer teeth turns faster. Gears on one shaft turn at the same speed. Power is passed on (minus losses), so torque goes up when speed goes down: T₂ = T₁·(N₂/N₁)·η, and P = T·ω with ω = 2π·n/60.
Output speed
nout = 2900·(18/20)·(12/18) = 1740 rpm
ωout = 2π·1740/60 = 182.2 rad/s
Output power and torque
Pout = 11000·0.97² = 10350 W
Tout = Pout/ωout = 10350/182.2 = 56.8 N·m
Answer
Tout = 56.8 N·m
5.Data acquisition & sampling
Answer: N = 10
ADC resolution: an N-bit converter divides its full-scale range VFSR into 2ᴺ codes, from 0 to 2ᴺ − 1. One step is 1 LSB = VFSR/2ᴺ: the smallest change the converter can show. A truncating ADC gives the code ⌊Vin/LSB⌋; a rounding ADC is never more than ½ LSB away from the true value, its quantisation error. Every extra bit halves the LSB and adds about 6 dB to the ideal signal-to-quantisation-noise ratio SQNR = 6.02·N + 1.76 dB for a full-scale sine. To reach a resolution r over a span, choose the smallest N with 2ᴺ ≥ span/r.
Steps needed
1000 mV/1 mV = 1000
Bits
log₂(1000) = 9.966
29 = 512 < 1000 ≤ 210 = 1024
N = 10
Answer
N = 10
6.Data acquisition & sampling
Answer: fa = 700 Hz
Sampling: an ADC measures the signal fs times per second. By the Nyquist–Shannon theorem a frequency f is captured correctly only while f < fs/2, the Nyquist (folding) frequency, so the sampling rate must exceed twice the highest signal frequency. A higher frequency is not lost: it shows up as an alias at fa = |f − k·fs|, with the whole number k that brings the result between 0 and fs/2. The samples cannot tell the two apart, so an analogue anti-aliasing filter must remove everything above fs/2 before the ADC.
Harmonic frequency
3f₁ = 3·900 Hz = 2.7 kHz
Nearest multiple of the sampling rate
m = round(1.35) = 1
Alias frequency
fa = |2700 − 1·2000| = 700 Hz
Answer
fa = 700 Hz
The alias lands inside the signal band, where no digital filter can remove it. Only an analogue filter before the ADC helps.
7.Wheatstone bridge & strain gauges
Answer: ΔR = 9.999 Ω
Wheatstone bridge: two voltage dividers share one supply Vs. The left divider R1–R2 gives Va = Vs·R2/(R1 + R2) and the right divider R3–R4 gives Vb = Vs·R4/(R3 + R4); the output is Vab = Va − Vb. The bridge is balanced (Vab = 0, no current in the meter) when R1/R2 = R3/R4, that is R1·R4 = R2·R3. Seen from the output, the bridge is a Thévenin source with Rth = R1∥R2 + R3∥R4.
Node voltage
Va = 1 + 0.0099 = 1.01 V
Solve the divider
R₂ = 500·1.01/(2 − 1.01) = 510 Ω
ΔR = 510 − 500 = 9.999 Ω
Answer
ΔR = 9.999 Ω
8.Wheatstone bridge & strain gauges
Answer: ε = 750 µε
Strain gauges: a gauge changes its resistance with strain: ΔR/R = GF·ε, where the gauge factor GF is about 2 for metal foil. In a bridge with all arms equal to R, one active gauge (quarter bridge) gives Vo ≈ Vs·GF·ε/4. Two active gauges with opposite strains in adjacent arms (half bridge) give Vs·GF·ε/2, and four (full bridge) give Vs·GF·ε. Stress follows from Hooke’s law, σ = E·ε. Load cells state their sensitivity in mV/V: the output at full load per volt of excitation.
Relative resistance change
ΔR/R = 1.575/1000 = 0.001575
Strain
ε = 0.001575/2.1 = 0.00075 = 750 µε
Answer
ε = 750 µε
9.Steady-state error & PID control
Answer: ess = 9.091 %
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Position constant
Kp = 10·1 = 10
Step error
ess = 100/(1 + 10) = 9.091 %
Answer
ess = 9.091 %
10.Steady-state error & PID control
Answer: tp = 0.2094 s
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 10) + 50·5 = s² + 10s + 250
ωₙ and ζ
ωₙ = √250 = 15.81 rad/s
ζ = 10/(2·15.81) = 0.3162
Peak time
ωd = 15.81·√(1 − 0.3162²) = 15 rad/s
tp = π/15 = 0.2094 s
Answer
tp = 0.2094 s
11.Step response
Answer: ωn = 7.211 rad/s
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 52 → ωₙ = 7.211 rad/s
2ζωₙ = 8 → ζ = 8/(2·7.211) = 0.5547
Result
ωₙ = 7.211 rad/s
Answer
ωn = 7.211 rad/s
12.Step response
Answer: K = 23.39
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).