In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
Gears & gear trains
Meshing gears
n1·N1 = n2·N2
Torque
T2 = T1·(N2/N1)·η
Power
P = T·ω, ω = 2π·n/60
Compound train
total ratio = product of the stage ratios
Data acquisition & sampling
Nyquist criterion
fs > 2·fmax, fN = fs/2
Alias frequency
fa = |f − k·fs|, k = round(f/fs)
Step size
1 LSB = VFSR/2ᴺ
Quantisation error (rounding)
±½ LSB
Truncating ADC code
D = ⌊Vin/LSB⌋
Bits for a resolution r
2ᴺ ≥ span/r
Ideal SQNR, full-scale sine
SQNR = 6.02·N + 1.76 dB
Data rate
channels × fs × N bit/s
Multiplexed ADC
fs = 1/(n·(tc + tset))
UART
Tb = 1/baud; 8N1 = 10 bits per byte; bytes/s = baud/bits per frame
Baud rate divider
baud = fclk/(16·D)
Method
Write down what is given: sampling rate, signal frequencies, number of bits, input range, baud rate.
For sampling questions, compare each frequency with fs/2; a higher frequency appears at fa = |f − k·fs| with the nearest multiple of fs.
For resolution questions, find 1 LSB = VFSR/2ᴺ, or the smallest N with 2ᴺ ≥ span/resolution.
For data rates and UART links, count everything that is sent: channels, samples per second, bits or whole bytes per sample, and the start, parity and stop bits of every frame.
Wheatstone bridge & strain gauges
Divider voltages
Va = VsR2/(R1 + R2), Vb = VsR4/(R3 + R4)
Output
Vab = Va − Vb
Balance
R1/R2 = R3/R4
Slide-wire bridge
R/Rx = l/(100 − l)
Thévenin resistance
Rth = R1∥R2 + R3∥R4
Gauge factor
ΔR/R = GF·ε
Bridge output
quarter Vs·GF·ε/4, half Vs·GF·ε/2, full Vs·GF·ε
Small change, one arm
Vab ≈ Vs·ΔR/(4R)
Stress
σ = E·ε
Method
Treat the bridge as two voltage dividers across the same supply.
For balance, set R₁/R₂ = R₃/R₄ and solve for the unknown resistor.
For an unbalanced bridge, find Va and Vb from the dividers and subtract; use the Thévenin equivalent when a meter loads the output.
For strain gauges, convert strain to ΔR/R = GF·ε and use Vs·GF·ε/4, /2 or ×1 for a quarter, half or full bridge.
Steady-state error & PID control
System type
number of poles of G(s) at s = 0
Error constants
Kp = lim G(s), Kv = lim s·G(s), Ka = lim s²·G(s) (s → 0)
Step A
ess = A/(1 + Kp)
Ramp A·t
ess = A/Kv
Parabola A·t²/2
ess = A/Ka
PID controller
C(s) = Kp + Ki/s + Kd·s
Second-order target
s² + 2ζωns + ωn²
Overshoot and timing
%OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd, ts ≈ 4/(ζωn)
Method
Count the poles of the open loop C(s)·G(s) at s = 0: that is the system type.
Work out the error constant that matches the input: Kp for a step, Kv for a ramp, Ka for a parabola.
Apply ess = A/(1 + Kp), A/Kv or A/Ka, or solve it for the gain you need.
For a damping or speed specification, write the closed-loop characteristic polynomial and match it with s² + 2ζω_n·s + ω_n².
2Practice problems
1.DC motorsMedium
A DC motor draws 40 A from a 240 V supply. Its armature resistance is 0.8 Ω and its rotational (friction, windage and iron) losses are 250 W. Find its efficiency η.
V = 240 VIa = 40 ARa = 0.8 ΩProt = 250 W
η = %
2.DC motorsHard
A DC motor (k = 1 V·s/rad, Ra = 0.4 Ω) on a fixed 220 V supply drives a load of 20 N·m. Find the series resistance Rs that slows it down to 900 rpm.
A 1.5 kW motor running at 1450 rpm drives a pinion with 15 teeth, which meshes with a gear with 32 teeth. The gear pair has an efficiency of 96%. Find the torque T1 on the motor shaft.
P = 1.5 kWn1 = 1450 rpmN1 = 15N2 = 32η = 96%
T1 = N·m
4.Gears & gear trainsHard
In a compound gear train, gear A (45 teeth) on the input shaft turns at 1440 rpm and drives gear B (72 teeth). Gear C (20 teeth) is fixed to the same shaft as B and drives gear D on the output shaft. The output must turn at 500 rpm. How many teeth ND must gear D have?
nin = 1440 rpmA = 45B = 72C = 20nout = 500 rpm
ND =
5.Data acquisition & samplingMedium
An 8-bit ADC with an input range of 0 to 5 V truncates: its output code is ⌊Vin/LSB⌋ with 1 LSB = VFSR/2ᴺ. Find the decimal output code D for an input of 2.282 V.
N = 8VFSR = 5 VVin = 2.282 V
D =
6.Data acquisition & samplingHard
A temperature sensor gives 10 mV/°C (0 V at 0 °C). Its signal is amplified 1 times and fed to a 10-bit ADC with a range of 0 to 3.3 V (1 LSB = VFSR/2ᴺ). Find the temperature change ΔTLSB that corresponds to one LSB.
S = 10 mV/°CG = 1N = 10VFSR = 3.3 V
ΔTLSB = °C
7.Wheatstone bridge & strain gaugesMedium
A bridge with four 100 Ω arms is supplied with 12 V. When the sensor R₂ changes, the output reads Vab = 59.41 mV. Find the exact change ΔR of R₂.
Vs = 12 VR = 100 ΩVab = 59.41 mV
ΔR = Ω
8.Wheatstone bridge & strain gaugesHard
A strain gauge (GF = 2.1) on a member with E = 70 GPa forms a quarter bridge excited with 10 V. The output reads 2.625 mV. Find the axial stress σ in MPa.
Vs = 10 VGF = 2.1Vo = 2.625 mVE = 70 GPa
σ = MPa
9.Steady-state error & PID controlMedium
A ramp r(t) = 4t is applied to a unity-feedback loop with G(s) = 4(s + 1)/(s(s + 1)(s + 10)). Find the steady-state error ess.
G(s) = 4(s + 1)/(s(s + 1)(s + 10))r(t) = 4t
ess =
10.Steady-state error & PID controlHard
A proportional controller K = 25 drives the plant G(s) = 1/(s(s + 6)) in a unity-feedback loop. Find the percent overshoot %OS of the step response.
G(s) = 1/(s(s + 6))K = 25
%OS = %
11.Step responseMedium
A system has the transfer function G(s) = 126/(s² + 3s + 42) and receives a unit step input. The poles are s = σ ± jωd. Find the real part σ.
G(s) = 126/(s² + 3s + 42)
σ =
12.Step responseHard
A series RLC circuit with R = 32 Ω, L = 50 mH and C = 2 µF is connected to a 10 V step at t = 0. The capacitor is uncharged and no current flows before the step. Find the peak capacitor voltage vC,max.
R = 32 ΩL = 50 mHC = 2 µFV = 10 V
vC,max = V
3Solutions
1.DC motors
Answer: η = 84.06 %
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Powers
Pin = 240·40 = 9600 W
Pdev = 208·40 = 8320 W
Pout = 8320 − 250 = 8070 W
Efficiency
η = 8070/9600·100 = 84.06 %
Answer
η = 84.06 %
2.DC motors
Answer: Rs = 5.888 Ω
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
Current and back-EMF
Ia = 20/1 = 20 A
E = 1·94.25 = 94.25 V
Series resistance
Ra + Rs = (220 − 94.25)/20 = 6.288 Ω
Rs = 5.888 Ω
Answer
Rs = 5.888 Ω
The resistor wastes 2355 W; a chopper controls the speed with far less loss.
3.Gears & gear trains
Answer: T1 = 9.879 N·m
Gear trains: meshing gears have the same speed at the teeth, so n₁·N₁ = n₂·N₂: the gear with fewer teeth turns faster. Gears on one shaft turn at the same speed. Power is passed on (minus losses), so torque goes up when speed goes down: T₂ = T₁·(N₂/N₁)·η, and P = T·ω with ω = 2π·n/60.
Motor torque
ω₁ = 2π·1450/60 = 151.8 rad/s
T1 = P/ω₁ = 1500/151.8 = 9.879 N·m
Answer
T1 = 9.879 N·m
4.Gears & gear trains
Answer: ND = 36
Gear trains: meshing gears have the same speed at the teeth, so n₁·N₁ = n₂·N₂: the gear with fewer teeth turns faster. Gears on one shaft turn at the same speed. Power is passed on (minus losses), so torque goes up when speed goes down: T₂ = T₁·(N₂/N₁)·η, and P = T·ω with ω = 2π·n/60.
Intermediate shaft speed
nB = nC = 1440·45/72 = 900 rpm
Teeth on gear D
ND = C·nC/nout = 20·900/500 = 36
Answer
ND = 36
5.Data acquisition & sampling
Answer: D = 116
ADC resolution: an N-bit converter divides its full-scale range VFSR into 2ᴺ codes, from 0 to 2ᴺ − 1. One step is 1 LSB = VFSR/2ᴺ: the smallest change the converter can show. A truncating ADC gives the code ⌊Vin/LSB⌋; a rounding ADC is never more than ½ LSB away from the true value, its quantisation error. Every extra bit halves the LSB and adds about 6 dB to the ideal signal-to-quantisation-noise ratio SQNR = 6.02·N + 1.76 dB for a full-scale sine. To reach a resolution r over a span, choose the smallest N with 2ᴺ ≥ span/r.
Step size
1 LSB = 5/28 = 19.53 mV
Code
Vin/LSB = 2282/19.53 = 116.8
code = ⌊116.8⌋ = 116
Answer
D = 116
In binary that is 01110100.
6.Data acquisition & sampling
Answer: ΔTLSB = 0.3223 °C
ADC resolution: an N-bit converter divides its full-scale range VFSR into 2ᴺ codes, from 0 to 2ᴺ − 1. One step is 1 LSB = VFSR/2ᴺ: the smallest change the converter can show. A truncating ADC gives the code ⌊Vin/LSB⌋; a rounding ADC is never more than ½ LSB away from the true value, its quantisation error. Every extra bit halves the LSB and adds about 6 dB to the ideal signal-to-quantisation-noise ratio SQNR = 6.02·N + 1.76 dB for a full-scale sine. To reach a resolution r over a span, choose the smallest N with 2ᴺ ≥ span/r.
Step size
1 LSB = 3300/1024 = 3.223 mV
Sensitivity at the ADC
10·1 = 10 mV/°C
Temperature resolution
ΔTLSB = 3.223/10 = 0.3223 °C
Answer
ΔTLSB = 0.3223 °C
The ADC reaches full scale at 330 °C.
7.Wheatstone bridge & strain gauges
Answer: ΔR = 2 Ω
Wheatstone bridge: two voltage dividers share one supply Vs. The left divider R1–R2 gives Va = Vs·R2/(R1 + R2) and the right divider R3–R4 gives Vb = Vs·R4/(R3 + R4); the output is Vab = Va − Vb. The bridge is balanced (Vab = 0, no current in the meter) when R1/R2 = R3/R4, that is R1·R4 = R2·R3. Seen from the output, the bridge is a Thévenin source with Rth = R1∥R2 + R3∥R4.
Node voltage
Va = 6 + 0.05941 = 6.059 V
Solve the divider
R₂ = 100·6.059/(12 − 6.059) = 102 Ω
ΔR = 102 − 100 = 2 Ω
Answer
ΔR = 2 Ω
8.Wheatstone bridge & strain gauges
Answer: σ = 35 MPa
Strain gauges: a gauge changes its resistance with strain: ΔR/R = GF·ε, where the gauge factor GF is about 2 for metal foil. In a bridge with all arms equal to R, one active gauge (quarter bridge) gives Vo ≈ Vs·GF·ε/4. Two active gauges with opposite strains in adjacent arms (half bridge) give Vs·GF·ε/2, and four (full bridge) give Vs·GF·ε. Stress follows from Hooke’s law, σ = E·ε. Load cells state their sensitivity in mV/V: the output at full load per volt of excitation.
Strain
ε = 4·0.002625/(10·2.1) = 0.0005
Stress
σ = 70·10³ MPa·0.0005 = 35 MPa
Answer
σ = 35 MPa
9.Steady-state error & PID control
Answer: ess = 10
Steady-state error: in a unity-feedback loop with open-loop transfer function G(s) the error is E(s) = R(s)/(1 + G(s)), and by the final value theorem ess = lims→0 s·E(s). The system type is the number of poles of G(s) at s = 0. The error constants are Kp = lim G(s), Kv = lim s·G(s) and Ka = lim s²·G(s), all for s → 0. A step of size A gives ess = A/(1 + Kp), a ramp A·t gives A/Kv and a parabola A·t²/2 gives A/Ka. A type-0 loop follows a step with a finite error, a type-1 loop follows it exactly and a ramp with a finite error.
Velocity constant
Kv = lim s·G(s) = 0.4
Ramp error
ess = 4/0.4 = 10
Answer
ess = 10
10.Steady-state error & PID control
Answer: %OS = 9.478 %
P, PI and PID control: the controller C(s) = Kp + Ki/s + Kd·s acts on the error. A proportional gain makes the loop faster and reduces the error of a type-0 plant, but never removes it. The integral term adds a pole at s = 0: the system type rises by one, and a step is followed without error. The derivative term adds damping. To choose gains, write the closed-loop characteristic polynomial and compare it with s² + 2ζωns + ωn². Then %OS = 100·e−ζπ/√(1−ζ²), tp = π/ωd with ωd = ωn√(1 − ζ²), and ts ≈ 4/(ζωn).
Characteristic polynomial
s(s + 6) + 25·1 = s² + 6s + 25
ωₙ and ζ
ωₙ = √25 = 5 rad/s
ζ = 6/(2·5) = 0.6
Overshoot
%OS = 100·e−0.6π/√(1 − 0.6²) = 9.478 %
Answer
%OS = 9.478 %
11.Step response
Answer: σ = −1.5
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).
Compare with the standard form
The denominator must match s² + 2ζωₙs + ωₙ².
ωₙ² = 42 → ωₙ = 6.481 rad/s
2ζωₙ = 3 → ζ = 3/(2·6.481) = 0.2315
Result
σ = −ζωₙ = −3/2 = −1.5
Answer
σ = −1.5
12.Step response
Answer: vC,max = 17.26 V
Step response: a first-order system G(s) = K/(τs + 1) answers a step of size U with y(t) = K·U·(1 − e−t/τ): it reaches 63.2 % of the final value K·U after one time constant τ and 98 % after 4τ. A second-order system G(s) = K·ωₙ²/(s² + 2ζωₙs + ωₙ²) has the poles s = −ζωₙ ± jωd with ωd = ωₙ√(1 − ζ²). For 0 < ζ < 1 the step response overshoots: percent overshoot %OS = 100·e−ζπ/√(1−ζ²), peak time tp = π/ωd, and the 2 % settling time ts ≈ 4/(ζωₙ). Compare the denominator with s² + 2ζωₙs + ωₙ² to read off ωₙ and ζ. For a mass–spring–damper ωₙ = √(k/m) and ζ = c/(2√(km)); for a series RLC circuit ωₙ = 1/√(LC) and ζ = (R/2)·√(C/L).