Power Systems and Electrical Machines: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

2Practice problems

1.Three-phase powerMedium
ABCVL​ = 480 VIL​ = 15 Acos φ = 0.7lagging

A balanced three-phase load draws a line current of 15 A from a supply with a line-to-line voltage of 480 V. The power factor is 0.7 lagging. Find the total real power P drawn by the load in kW.

VL = 480 VIL = 15 Acos φ = 0.7
P = kW
2.Three-phase powerHard
P = 300 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 300 kW at a power factor of 0.7 lagging from a 690 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.92 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 300 kWpf1 = 0.7pf2 = 0.92VL = 690 Vf = 50 Hz
QC = kvar
3.TransformersMedium
5 ΩN1​N2​720 Ω

An amplifier with an output resistance of 720 Ω drives a 5 Ω loudspeaker through an ideal transformer. For maximum power transfer the loudspeaker must look like 720 Ω from the amplifier. Find the turns ratio a = N₁/N₂.

Rs = 720 ΩRL = 5 Ω
a =
4.TransformersHard
pf 0.8550 kVA, η = 98.8%

A single-phase 50 kVA transformer has a core loss of 250 W. At rated load and a power factor of 0.85 lagging its efficiency is 98.8%. Find the full-load copper loss Pcu,fl in watts.

S = 50 kVAPcore = 250 Wpf = 0.85η = 98.8%
Pcu,fl = W
5.AC power & power factorMedium
230 VR + jXP = 2737 W14 A

An inductive load takes 14 A and 2737 W from a 230 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find R.

V = 230 VI = 14 AP = 2737 W
R = Ω
6.AC power & power factorHard
P1​ = 36 kWQ1​S1​φ

A 100 kVA single-phase transformer supplies a load of 36 kW at a power factor of 0.7 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?

Smax = 100 kVAP1 = 36 kWpf1 = 0.7
ΔP = kW
7.AC impedance & phasorsMedium
230 V60 HzR = 30 ΩL = 20 mHC = 22 µFI

A series RLC circuit is connected to a 230 V (rms), 60 Hz supply. Find the power factor cos φ of the circuit.

V = 230 V (rms)f = 60 HzR = 30 ΩL = 20 mHC = 22 µF
cos φ =
8.AC impedance & phasorsHard
120 V50 HzR = 25 ΩL = 100 mHC = 22 µF

A series RLC circuit is connected to a 120 V (rms), 50 Hz supply. Find the resonant frequency f0 of the circuit.

V = 120 V (rms)f = 50 HzR = 25 ΩL = 100 mHC = 22 µF
f0 = Hz
9.DC motorsMedium
T (N·m)n (rpm)Tst​ = ?n0​

A DC motor with k = 0.75 N·m/A and Ra = 0.25 Ω is connected to 48 V. Find its stall torque Tstall, the torque at zero speed.

V = 48 Vk = 0.75 N·m/ARa = 0.25 Ω
Tstall = N·m
10.DC motorsHard
+−240 VD = ?Ra​ = 0.5 ΩM+−En = 400 rpmT = 18.75 N·m

A DC chopper feeds a motor (k = 0.75 V·s/rad, Ra = 0.5 Ω) from a 240 V DC bus. The average armature voltage is D·240 V. Find the duty cycle D that runs the motor at 400 rpm with a load of 18.75 N·m.

Vdc = 240 Vk = 0.75 V·s/radRa = 0.5 ΩT = 18.75 N·mn = 400 rpm
D = %

3Solutions

1.Three-phase power

Answer: P = 8.73 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Apparent power

S = √3·VL·IL = √3·480·15 = 12.47 kVA

Real power

P = S·cos φ = 12.47·0.7 = 8.73 kW

Answer

P = 8.73 kW
2.Three-phase power

Answer: QC = 178.3 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 300·tan(acos 0.7) = 300·1.02 = 306.1 kvar
Q2 = 300·tan(acos 0.92) = 300·0.426 = 127.8 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 178.3 kvar

Answer

QC = 178.3 kvar
3.Transformers

Answer: a = 12

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Match the referred load

a²·5 = 720
a = √(720/5) = √144 = 12

Answer

a = 12
4.Transformers

Answer: Pcu,fl = 266.2 W

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Output and input power

Pout = 50·0.85 = 42.5 kW
Pin = 42500/0.988 = 43016 W

Total and copper losses

Ploss = 43016 − 42500 = 516.2 W
Pcu,fl = 516.2 − 250 = 266.2 W

Answer

Pcu,fl = 266.2 W
5.AC power & power factor

Answer: R = 13.96 Ω

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Resistance from the real power

R = P/I² = 2737/14² = 13.96 Ω

Answer

R = 13.96 Ω
6.AC power & power factor

Answer: ΔP = 57.01 kW

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of the existing load

Q1 = 36·tan(arccos 0.7) = 36.73 kvar

Largest total real power

At full rating S = Smax, and Q is unchanged by the resistive load.

P = √(Smax² − Q1²) = √(100² − 36.73²) = 93.01 kW

Extra real power

ΔP = 93.01 − 36 = 57.01 kW

Answer

ΔP = 57.01 kW
7.AC impedance & phasors

Answer: cos φ = 0.2565

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactances

XL = 7.54 Ω, XC = 120.6 Ω

Impedance

|Z| = √(30² + (−113)²) = 116.9 Ω

Power factor

cos φ = R/|Z| = 30/116.9 = 0.2565
The circuit is capacitive, so the power factor is leading.

Answer

cos φ = 0.2565
8.AC impedance & phasors

Answer: f0 = 107.3 Hz

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonance

At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC). The supply frequency does not matter.

f0 = 1/(2π√(LC)) = 1/(2π·√(0.1·22·10⁻⁶)) = 107.3 Hz

Answer

f0 = 107.3 Hz
9.DC motors

Answer: Tstall = 144 N·m

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Stall current

Ia = V/Ra = 48/0.25 = 192 A

Stall torque

Tstall = 0.75·192 = 144 N·m

Answer

Tstall = 144 N·m
10.DC motors

Answer: D = 18.3 %

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Required armature voltage

Va = 0.75·41.89 + 25·0.5 = 43.92 V

Duty cycle

D = 43.92/240 = 18.3 %

Answer

D = 18.3 %

ExamProblems · examproblems.com/courses/power-systems