Power Systems and Electrical Machines: cram pack

Formula sheets, the key method steps for every topic and 10 practice problems, with full solutions at the back.

New problemsBack to the course

In the print window, choose “Save as PDF” to keep a copy on your device.

1Formulas and methods

Three-phase power

Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η

Transformers

Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)

AC power & power factor

Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)

AC impedance & phasors

Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z

Method

  1. Convert the frequency: ω = 2πf.
  2. Find each reactance: XL = ωL and XC = 1/(ωC).
  3. Add impedances like resistors, with Z = R + jX.
  4. Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.

DC motors

Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc

Method

  1. Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
  2. Use V = E + Ia·Ra to link voltage, current and back-EMF.
  3. Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
  4. For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.

2Practice problems

1.Three-phase powerMedium
ABCVL​ = 400 VZ = 24 + j18 Ωper phase

A balanced Δ-connected load with an impedance of 24 + j18 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 400 V. Find the total real power P absorbed by the load in kW.

VL = 400 VZ = 24 + j18 Ω per phase
P = kW
2.Three-phase powerHard
P = 300 kWφ1​S1​Q2​QC​ = ?

A balanced three-phase load takes 300 kW at a power factor of 0.7 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.

P = 300 kWpf1 = 0.7pf2 = 0.9VL = 415 Vf = 50 Hz
QC = kvar
3.TransformersMedium
4 Ω101

A 4 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 10:1. Find the resistance R1′ seen looking into the primary winding.

N1:N2 = 10:1RL = 4 Ω
R1′ = Ω
4.TransformersHard
150 kVA

A single-phase 150 kVA transformer has a core loss of 450 W and a copper loss of 1350 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?

S = 150 kVAPcore = 450 WPcu,fl = 1350 W
Sη,max = kVA
5.AC power & power factorMedium
240 V122 kW, 0.6523 kW, 1I

Two loads are connected in parallel to a 240 V single-phase supply: a 22 kW load at a power factor of 0.65 lagging and a 3 kW heater (unity power factor). Find the overall power factor cos φ seen by the supply.

V = 240 VP1 = 22 kW, pf1 = 0.65 laggingP2 = 3 kW, pf2 = 1
cos φ =
6.AC power & power factorHard
P = 20 kWQ1​S1​φ1​QC​

A single-phase load takes 20 kW at a power factor of 0.6 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.

P = 20 kWpf1 = 0.6pf2 = 0.92V = 230 Vf = 50 Hz
Inew = A
7.AC impedance & phasorsMedium
Vf0​ = 200 HzRL = ?C = 10 µF

A series RLC circuit with C = 10 µF must resonate at 200 Hz. Find the inductance L needed.

f0 = 200 HzC = 10 µF
L = mH
8.AC impedance & phasorsHard
24 V200 HzR1​ = 20 ΩR2​ = 30 ΩC = 47 µFI

A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 24 V (rms), 200 Hz supply. Find the rms current I.

V = 24 V (rms)f = 200 HzR1 = 20 ΩR2 = 30 ΩC = 47 µF
I = A
9.DC motorsMedium
T (N·m)n (rpm)n0​ = ?

A DC motor with k = 2 V·s/rad runs from 240 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.

V = 240 Vk = 2 V·s/rad
n0 = rpm
10.DC motorsHard
+−220 VD = ?Ra​ = 1 ΩM+−En = 900 rpmT = 6.4 N·m

A DC chopper feeds a motor (k = 0.8 V·s/rad, Ra = 1 Ω) from a 220 V DC bus. The average armature voltage is D·220 V. Find the duty cycle D that runs the motor at 900 rpm with a load of 6.4 N·m.

Vdc = 220 Vk = 0.8 V·s/radRa = 1 ΩT = 6.4 N·mn = 900 rpm
D = %

3Solutions

1.Three-phase power

Answer: P = 12.8 kW

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.

Phase voltage

Vph = VL = 400 V

Phase current

|Z| = √(24² + 18²) = 30 Ω
Iph = 400/30 = 13.33 A

Total real power

Only the resistive part of each impedance absorbs real power.

P = 3·Iph²·R = 3·13.33²·24 = 12.8 kW

Answer

P = 12.8 kW

Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.

2.Three-phase power

Answer: QC = 160.8 kvar

Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.

Reactive power before and after

The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.

Q1 = 300·tan(acos 0.7) = 300·1.02 = 306.1 kvar
Q2 = 300·tan(acos 0.9) = 300·0.4843 = 145.3 kvar

Reactive power from the capacitors

QC = Q1 − Q2 = 160.8 kvar

Answer

QC = 160.8 kvar
3.Transformers

Answer: R1′ = 400 Ω

Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.

Referred resistance

The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².

R1′ = a²·RL = 10²·4 = 400 Ω

Answer

R1′ = 400 Ω
4.Transformers

Answer: Sη,max = 86.6 kVA

Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.

Copper loss equals core loss

x²·1350 = 450 → x = √(450/1350) = 0.5774

Load at maximum efficiency

Sη,max = x·S = 0.5774·150 = 86.6 kVA

Answer

Sη,max = 86.6 kVA
5.AC power & power factor

Answer: cos φ = 0.697

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power of each load

A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).

Q1 = 22·tan(arccos 0.65) = 25.72 kvar
Q2 = 0 = 0 kvar

Totals

P = 22 + 3 = 25 kW
Q = 25.72 + 0 = 25.72 kvar
S = √(25² + 25.72²) = 35.87 kVA

Overall power factor

cos φ = P/S = 25/35.87 = 0.697 lagging

Answer

cos φ = 0.697
6.AC power & power factor

Answer: Inew = 94.52 A

AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.

Reactive power before and after

The real power P does not change; only the reactive power drawn from the supply does.

Q1 = P·tan φ1 = 20·tan(53.13°) = 26.67 kvar
Q2 = P·tan φ2 = 20·tan(23.07°) = 8.52 kvar
QC = Q1 − Q2 = 18.15 kvar

New line current

Inew = P/(V·cos φ2) = 20000/(230·0.92) = 94.52 A

Answer

Inew = 94.52 A
7.AC impedance & phasors

Answer: L = 63.33 mH

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Resonance condition

At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).

ω₀ = 2π·200 = 1257 rad/s
L = 1/(ω₀²·C) = 1/(1257²·10·10⁻⁶) = 63.33 mH

Answer

L = 63.33 mH
8.AC impedance & phasors

Answer: I = 0.7968 A

AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.

Reactance

XC = 1/(2π·200·47·10⁻⁶) = 16.93 Ω

Parallel combination

Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.

Zp = R₂·(−jXC)/(R₂ − jXC) = (R₂·XC² − jR₂²·XC)/(R₂² + XC²)
Zp = 7.247 − j12.84 Ω

Total impedance

Z = 20 + 7.247 − j12.84 = 27.25 − j12.84 Ω
|Z| = √(27.25² + 12.84²) = 30.12 Ω

Current

I = V/|Z| = 24/30.12 = 0.7968 A

Answer

I = 0.7968 A
9.DC motors

Answer: n0 = 1146 rpm

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

No-load speed

ω₀ = V/k = 240/2 = 120 rad/s
n0 = 60·120/(2π) = 1146 rpm

Answer

n0 = 1146 rpm
10.DC motors

Answer: D = 37.91 %

DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.

Required armature voltage

Va = 0.8·94.25 + 8·1 = 83.4 V

Duty cycle

D = 83.4/220 = 37.91 %

Answer

D = 37.91 %

ExamProblems · examproblems.com/courses/power-systems