In the print window, choose “Save as PDF” to keep a copy on your device.
1Formulas and methods
Three-phase power
Y connection
VL = √3·Vph, IL = Iph
Δ connection
VL = Vph, IL = √3·Iph
Total real power
P = √3·VL·IL·cos φ = 3·Iph²·R
Apparent and reactive power
S = √3·VL·IL, Q = P·tan φ
Correction capacitors
QC = P(tan φ1 − tan φ2), C = QC/(3ωV²)
Voltage across each capacitor
Δ: VL Y: VL/√3
Motor input
Pin = Pout/η
Transformers
Turns ratio
a = N1/N2 = V1/V2
Current ratio
I1/I2 = N2/N1 = 1/a
Rated current
I = S/V
Referred impedance
Z1′ = a²·ZL
Copper loss at part load
Pcu = x²·Pcu,fl
Efficiency
η = x·S·pf/(x·S·pf + Pcore + x²·Pcu,fl)
Maximum efficiency
x = √(Pcore/Pcu,fl)
AC power & power factor
Real power
P = V·I·cos φ
Reactive power
Q = V·I·sin φ
Apparent power
S = V·I = √(P² + Q²)
Power factor
pf = cos φ = P/S
Correction capacitor
QC = P(tan φ1 − tan φ2), C = QC/(ωV²)
AC impedance & phasors
Impedances
ZR = R, ZL = jωL, ZC = 1/(jωC)
Angular frequency
ω = 2πf
Magnitude and angle
|Z| = √(R² + X²), φ = atan(X/R)
Phasor Ohm’s law
V = I·Z
Method
Convert the frequency: ω = 2πf.
Find each reactance: XL = ωL and XC = 1/(ωC).
Add impedances like resistors, with Z = R + jX.
Find the magnitude |Z| = √(R² + X²) and the angle φ = atan(X/R), then use Ohm’s law with phasors.
DC motors
Armature circuit
V = E + IaRa
Back-EMF and torque
E = k·ω, T = k·Ia
Speed
ω = 2π·n/60, ω = (V − IaRa)/k
No-load speed and stall torque
ω0 = V/k, Tstall = k·V/Ra
Powers
Pin = V·Ia, Pdev = E·Ia = T·ω, Pout = Pdev − Prot
Starting
Istart = V/(Ra + Rst)
Speed regulation
SR = (n0 − nFL)/nFL
Maximum developed power
Pmax = V²/(4Ra)
Chopper drive
Va = D·Vdc
Method
Draw the armature circuit: supply V, resistance Ra and the back-EMF E in series.
Use V = E + Ia·Ra to link voltage, current and back-EMF.
Use E = k·ω for speed and T = k·Ia for torque, with ω = 2π·n/60.
For power and efficiency, start from V·Ia, subtract the copper loss Ia²·Ra and then the rotational losses.
2Practice problems
1.Three-phase powerMedium
A balanced Δ-connected load with an impedance of 24 + j18 Ω per phase is connected to a balanced three-phase supply with a line-to-line voltage of 400 V. Find the total real power P absorbed by the load in kW.
VL = 400 VZ = 24 + j18 Ω per phase
P = kW
2.Three-phase powerHard
A balanced three-phase load takes 300 kW at a power factor of 0.7 lagging from a 415 V (line-to-line), 50 Hz supply. A three-phase capacitor bank in parallel with the load must raise the overall power factor to 0.9 lagging. The real power stays the same. Find the total reactive power QC the capacitor bank must supply, in kvar.
P = 300 kWpf1 = 0.7pf2 = 0.9VL = 415 Vf = 50 Hz
QC = kvar
3.TransformersMedium
A 4 Ω resistor is connected across the secondary winding of an ideal transformer with a turns ratio N₁:N₂ = 10:1. Find the resistance R1′ seen looking into the primary winding.
N1:N2 = 10:1RL = 4 Ω
R1′ = Ω
4.TransformersHard
A single-phase 150 kVA transformer has a core loss of 450 W and a copper loss of 1350 W at rated load. At what load Sη,max, in kVA, is its efficiency highest?
S = 150 kVAPcore = 450 WPcu,fl = 1350 W
Sη,max = kVA
5.AC power & power factorMedium
Two loads are connected in parallel to a 240 V single-phase supply: a 22 kW load at a power factor of 0.65 lagging and a 3 kW heater (unity power factor). Find the overall power factor cos φ seen by the supply.
A single-phase load takes 20 kW at a power factor of 0.6 lagging from a 230 V, 50 Hz supply. A capacitor connected in parallel raises the power factor to 0.92. Find the new line current Inew.
P = 20 kWpf1 = 0.6pf2 = 0.92V = 230 Vf = 50 Hz
Inew = A
7.AC impedance & phasorsMedium
A series RLC circuit with C = 10 µF must resonate at 200 Hz. Find the inductance L needed.
f0 = 200 HzC = 10 µF
L = mH
8.AC impedance & phasorsHard
A resistor R1 is connected in series with a parallel combination of R2 and a capacitor C, across a 24 V (rms), 200 Hz supply. Find the rms current I.
V = 24 V (rms)f = 200 HzR1 = 20 ΩR2 = 30 ΩC = 47 µF
I = A
9.DC motorsMedium
A DC motor with k = 2 V·s/rad runs from 240 V. Neglecting all losses at no load, find its no-load speed n0 in rpm.
V = 240 Vk = 2 V·s/rad
n0 = rpm
10.DC motorsHard
A DC chopper feeds a motor (k = 0.8 V·s/rad, Ra = 1 Ω) from a 220 V DC bus. The average armature voltage is D·220 V. Find the duty cycle D that runs the motor at 900 rpm with a load of 6.4 N·m.
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ.
Phase voltage
Vph = VL = 400 V
Phase current
|Z| = √(24² + 18²) = 30 Ω
Iph = 400/30 = 13.33 A
Total real power
Only the resistive part of each impedance absorbs real power.
P = 3·Iph²·R = 3·13.33²·24 = 12.8 kW
Answer
P = 12.8 kW
Check: cos φ = R/|Z| = 0.8, and √3·VL·IL·cos φ gives the same power.
2.Three-phase power
Answer: QC = 160.8 kvar
Balanced three-phase systems: in a Y (star) connection the line-to-line voltage is √3 times the phase voltage, VL = √3·Vph, and the line current equals the phase current. In a Δ (delta) connection the line-to-line voltage equals the phase voltage and the line current is √3 times the phase current, IL = √3·Iph. The total power is three times the power of one phase: P = 3·Vph·Iph·cos φ = √3·VL·IL·cos φ. Power factor correction: capacitors supply reactive power locally, QC = P·(tan φ1 − tan φ2). Each of the three capacitors supplies QC/3 = V²·ω·C, where V is the voltage across that capacitor: VL in a Δ bank, VL/√3 in a Y bank.
Reactive power before and after
The real power is unchanged, so each power factor fixes the reactive power: Q = P·tan φ.
Q1 = 300·tan(acos 0.7) = 300·1.02 = 306.1 kvar
Q2 = 300·tan(acos 0.9) = 300·0.4843 = 145.3 kvar
Reactive power from the capacitors
QC = Q1 − Q2 = 160.8 kvar
Answer
QC = 160.8 kvar
3.Transformers
Answer: R1′ = 400 Ω
Ideal transformer: the voltages are in the ratio of the turns and the currents in the inverse ratio: V₁/V₂ = N₁/N₂ = a and I₁/I₂ = N₂/N₁ = 1/a, so the power in equals the power out, V₁·I₁ = V₂·I₂. A load impedance Z on the secondary looks like a²·Z from the primary.
Referred resistance
The voltage goes up by a and the current down by a, so the ratio V/I goes up by a².
R1′ = a²·RL = 10²·4 = 400 Ω
Answer
R1′ = 400 Ω
4.Transformers
Answer: Sη,max = 86.6 kVA
Transformer losses: the core loss (hysteresis and eddy currents) depends on the voltage and is the same at any load. The copper loss in the windings goes with the current squared, so at a fraction x of rated load it is x²·Pcu,fl. Efficiency η = Pout/(Pout + Pcore + Pcu), with Pout = x·S·pf. The efficiency is highest at the load where the copper loss equals the core loss.
Copper loss equals core loss
x²·1350 = 450 → x = √(450/1350) = 0.5774
Load at maximum efficiency
Sη,max = x·S = 0.5774·150 = 86.6 kVA
Answer
Sη,max = 86.6 kVA
5.AC power & power factor
Answer: cos φ = 0.697
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power of each load
A lagging load takes reactive power (Q > 0); a leading load supplies it (Q < 0).
Q1 = 22·tan(arccos 0.65) = 25.72 kvar
Q2 = 0 = 0 kvar
Totals
P = 22 + 3 = 25 kW
Q = 25.72 + 0 = 25.72 kvar
S = √(25² + 25.72²) = 35.87 kVA
Overall power factor
cos φ = P/S = 25/35.87 = 0.697 lagging
Answer
cos φ = 0.697
6.AC power & power factor
Answer: Inew = 94.52 A
AC power: apparent power S = V·I (VA) splits into real power P = S·cos φ (W), which does useful work, and reactive power Q = S·sin φ (var), which moves back and forth between source and load. The power factor is cos φ. A capacitor in parallel supplies reactive power locally, so the line current drops for the same real power.
Reactive power before and after
The real power P does not change; only the reactive power drawn from the supply does.
Q1 = P·tan φ1 = 20·tan(53.13°) = 26.67 kvar
Q2 = P·tan φ2 = 20·tan(23.07°) = 8.52 kvar
QC = Q1 − Q2 = 18.15 kvar
New line current
Inew = P/(V·cos φ2) = 20000/(230·0.92) = 94.52 A
Answer
Inew = 94.52 A
7.AC impedance & phasors
Answer: L = 63.33 mH
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Resonance condition
At resonance the inductive and capacitive reactances cancel: ωL = 1/(ωC).
ω₀ = 2π·200 = 1257 rad/s
L = 1/(ω₀²·C) = 1/(1257²·10·10⁻⁶) = 63.33 mH
Answer
L = 63.33 mH
8.AC impedance & phasors
Answer: I = 0.7968 A
AC circuits with phasors: resistors, inductors and capacitors have impedances R, jωL and 1/(jωC), with ω = 2πf. In series, impedances add like resistances, but as complex numbers. Rms current and voltage follow Ohm’s law with |Z|.
Reactance
XC = 1/(2π·200·47·10⁻⁶) = 16.93 Ω
Parallel combination
Multiply top and bottom by the complex conjugate to split Zp into real and imaginary parts.
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.
No-load speed
ω₀ = V/k = 240/2 = 120 rad/s
n0 = 60·120/(2π) = 1146 rpm
Answer
n0 = 1146 rpm
10.DC motors
Answer: D = 37.91 %
DC motor: the armature is a resistance Ra in series with the back-EMF E, so V = E + Ia·Ra. The back-EMF grows with speed, E = k·ω, and the torque with current, T = k·Ia, with the same motor constant k (V·s/rad = N·m/A) in SI units. Convert speeds with ω = 2π·n/60. The developed power is E·Ia = T·ω; the input power is V·Ia, and the copper loss Ia²Ra and the rotational loss make the difference. The speed falls in a straight line with torque, ω = V/k − Ra·T/k², from the no-load speed V/k to zero at the stall torque k·V/Ra. At standstill E = 0, so the starting current V/Ra is large unless a resistor limits it.