AC power & power factor worksheet with answers

Free printable AC power & power factor worksheet: 6 problems from easy to exam level, with an answer key. Print it or save it as a PDF.

For teachers: free to print, copy and use in class. Every new worksheet has new values and its own answer key. A link to ExamProblems on your course page is appreciated.

Name: ____________________   Date: ____________

1.Easy
240 VloadP = 2340 W15 A

A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 15 A and 2340 W. Find the power factor cos φ of the load.

V = 240 VI = 15 AP = 2340 W
cos φ =
2.Easy
240 VloadP = 1080 W6 A

A voltmeter, an ammeter and a wattmeter connected to a single-phase inductive load read 240 V, 6 A and 1080 W. Find the power factor cos φ of the load.

V = 240 VI = 6 AP = 1080 W
cos φ =
3.Medium
240 VR + jXP = 2958 W14.5 A

An inductive load takes 14.5 A and 2958 W from a 240 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.

V = 240 VI = 14.5 AP = 2958 W
X = Ω
4.Medium
230 VR + jXP = 1173 W6 A

An inductive load takes 6 A and 1173 W from a 230 V (rms) single-phase supply. Model it as a resistance R in series with a reactance X. Find X.

V = 230 VI = 6 AP = 1173 W
X = Ω
5.Hard
100 V60 HzRs​ = 20 ΩXs​ = j6 ΩZL​ = ?

A 100 V (rms), 60 Hz source has an internal impedance Zs = 20 + j6 Ω. The load impedance ZL can be chosen freely. Find the maximum real power Pmax that can be delivered to the load.

Vs = 100 V (rms)f = 60 HzZs = 20 + j6 Ω
Pmax = W
6.Hard
240 V60 Hzload9 kW, 0.75C47 µFI = ?

A single-phase load takes 9 kW at a power factor of 0.75 lagging from a 240 V, 60 Hz supply. A 47 µF capacitor is connected in parallel with the load. Find the new line current I.

P = 9 kWpf1 = 0.75V = 240 Vf = 60 HzC = 47 µF
I = A

Answer key

  1. 1. cos φ = 0.65
  2. 2. cos φ = 0.75
  3. 3. X = 8.719 Ω
  4. 4. X = 20.19 Ω
  5. 5. Pmax = 125 W
  6. 6. I = 47.29 A