A single-phase load draws 4 A (rms) from a 120 V (rms) supply at a power factor of 0.65 lagging. Find the reactive power Q it takes.
AC power & power factor worksheet with answers
A single-phase load draws 3 A (rms) from a 230 V (rms) supply at a power factor of 0.65 lagging. Find the real power P it takes.
A load with impedance Z = 20 + j15 Ω is connected to a 240 V (rms) single-phase supply. Find the reactive power Q it absorbs.
A single-phase motor takes 30 kW at a power factor of 0.7 lagging from a 240 V supply. Find the reactive power Q it draws.
A 100 V (rms), 1000 Hz source has an internal impedance Zs = 2 + j20 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
A 25 kVA single-phase transformer supplies a load of 16 kW at a power factor of 0.85 lagging. How much extra real power ΔP can be added as a resistive (unity power factor) load before the transformer reaches its kVA rating?
Answer key
- 1. Q = 364.8 var
- 2. P = 448.5 W
- 3. Q = 1382 var
- 4. Q = 30.61 kvar
- 5. C = 7.958 µF
- 6. ΔP = 6.949 kW