A single-phase load draws 20 A (rms) from a 240 V (rms) supply at a power factor of 0.6 lagging. Find the reactive power Q it takes.
AC power & power factor worksheet with answers
A single-phase load connected to a 400 V supply takes 15 kW and 19.5 kvar. Find the current I drawn from the supply.
A single-phase motor takes 15 kW at a power factor of 0.7 lagging from a 240 V supply. Find the reactive power Q it draws.
A single-phase motor takes 10 kW at a power factor of 0.6 lagging from a 240 V supply. Find the line current I.
A 120 V (rms), 50 Hz source has an internal impedance Zs = 20 + j40 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
A 50 V (rms), 1000 Hz source has an internal impedance Zs = 2 + j15 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Answer key
- 1. Q = 3840 var
- 2. I = 61.5 A
- 3. Q = 15.3 kvar
- 4. I = 69.44 A
- 5. C = 79.58 µF
- 6. C = 10.61 µF
Full step-by-step solutions: practise this topic on examproblems.com.