A single-phase load draws 17 A (rms) from a 120 V (rms) supply at a power factor of 0.95 lagging. Find the reactive power Q it takes.
AC power & power factor worksheet with answers
A single-phase load connected to a 240 V supply takes 27 kW and 18.5 kvar. Find the current I drawn from the supply.
A single-phase motor takes 8 kW at a power factor of 0.65 lagging from a 240 V supply. Find the line current I.
A single-phase motor takes 1 kW at a power factor of 0.85 lagging from a 230 V supply. Find the reactive power Q it draws.
A single-phase load takes 28 kW at a power factor of 0.65 lagging from a 240 V, 60 Hz supply. A 330 µF capacitor is connected in parallel with the load. Find the new power factor cos φ seen by the supply.
A 100 V (rms), 50 Hz source has an internal impedance Zs = 50 + j40 Ω. The load impedance ZL can be chosen freely. The load for maximum power is built from a resistor in series with a capacitor. Find the capacitance C.
Answer key
- 1. Q = 637 var
- 2. I = 136.4 A
- 3. I = 51.28 A
- 4. Q = 0.6197 kvar
- 5. cos φ = 0.7384
- 6. C = 79.58 µF